SY16C Excavator OMM
Maintenance
SANY
Operation and Maintenance Manual — 0420
5-41
TABL
E OF
CONT
E
N
TS
INTRODUCTION
SAFE
T
Y
MACHIN
E
CONTROLS
MACHINE
OP
ERA
T
IO
N
MA
INTENANCE
SPEC
IFI
CA
TIO
N
S
OP
T
IO
N
A
L
EQUI
PMENT
5. Remove fasteners (1) and the hydraulic oil filler cover
(2).
6. Place a suitable container under the hydraulic tank
drain plug (1).
•
NOTE:
For hydraulic tank capacity, see “Fluid
Capacities” on page 5-9.
7. Remove the hydraulic tank drain plug (3) and allow the
oil to drain.
8. Remove fasteners (4) and the cover plate (5).
NOTE:
The hydraulic return filter and screen are
behind the cover plate and can be removed.
9. Clean the inside of the hydraulic tank.
10. Reinstall the cover plate, return filter and screen.
11. Install and tighten the drain plug.
12. Fill the hydraulic tank to the specified level. See “Add Hydraulic Oil” on page 5-37.
Collect Hydraulic Oil Sample
1. Obtain an oil analysis sample kit from a SANY dealer.
2. Operate the machine until the hydraulic oil is up to normal operating temperature.
3. Prepare the machine for service. See “Maintenance Safety” on page 2-9.
4. Remove the hydraulic tank breather assembly. See “Add Hydraulic Oil” on page 5-37.
5. Insert the sample tube into the hydraulic tank and collect a sample of hydraulic oil. Reinstall the hydraulic tank
breather assembly.
6. Send the sample for testing in accordance with the instructions packaged with the sample kit.
NOTICE!
It is critical that all material used to collect the sample is absolutely clean. Failure to adhere to
this warning can cause equipment damage and contaminate the sample.
Fig. 5-29
0005145
3
1
2
4
4
5