- …31…-
5-6 Escalator Emergency Stop Distance Measurement (mm)
Set the measurement unit to mm (see section 5-2).
The CH1 display shows [
] and the CH2 display shows [ ] to
indicate that the distance can be measured.
Attach the peripheral speed ring for speed measurement securely
on the instrument and apply the ring onto the handrail of the escalator.
Start measurement by pressing the CH1 button or apply external
triggering for CH1.
To finish the measurement, press the CH2 button or apply external
triggering for CH2.
The measurement also finishes when the ring has not be rotated for
2 sec. or more.
After the measurement, the CH1 display shows [
] and the CH2
display shows the distance. If you want to save the measurement
value in memory, press the SAVE button.
To perform another measurement, turn the instrument OFF then ON again.
Standby
or
no pulse
for 2 sec.
Start of
measurement
During
measurement
End of
measurement
→
→
→
→
Hold
* When the measurement value is 999 mm or more, the display
shows “OL”.
* If the peripheral speed ring rotates in the opposite direction
during measurement, the distance is also added to the mea-
surement. For example, assuming that a 20 mm ring rotates and
then returns by 1 mm, the measurement value becomes
20 mm + 1 mm = 21 mm.