− 15 −
Operating
environmental
conditions
Altitude 2000 m or below, indoor use, pollution
degree II
Operating
temperature/
humidity ranges
0-40 ºC, max. relative humidity 85 % (no
condensation)
Storage temperature/
humidity range
-20-60 ºC, max. relative humidity 90 %,
no condensation (with batteries removed)
(Batteries should be removed before storage
for a long period.)
Power supply
R6P 1.5
V × 6pcs
Auto Power Off
Power OFF in about 10 minutes after last
operation.
Power consumption Approx. 18 VA (measurement at 5000 V/
approx. 1.8 MΩ)
Possible number of
measurements
4000 times
3-pole method measure 10 Ω, 5 seconds
continuous, 25 seconds interval
Dimensions & mass
163(H) × 102(W) × 50(D) approx. 440 g(incl.
batteries)
Year of production
Initial 2 digits of the main unit serial No.
indicate the last two digits of year (20**).
IP rate
IP30
Standard
IEC61010-1 CAT.II 400 V/III 300 V
IEC61010-2-030, IEC61010-2-033,
IEC61010-031
IEC61557-1, -5
EMC, RoHS
IEC61326(EMC)
,
EN50581(RoHS)
Accessory
TL-67: Test lead set (black 5 m x 1pc., blue
10 m x 1pc., red 15 m x 1pc.)
CL-ER4000: Auxiliary earth electrode x
2pcs
C-PDR4000: Carrying case
Manual
Battery: R6P(1.5 V) x 6pcs.
Optional accessory
For 2-pole method: TL-68