6-4-1 DCV Measurement
( ) Max. measurement value 1000 VDC
1) Application
Measuring batteries or DC circuits.
2) Measuring range: 120 m/3/12/30/120/300/1000 (7ranges)
6-4 Voltage Measurement
1.Never apply an input signals exceeding the maximum
rating input value.
2.Be sure to disconnect the test pins from the circuit when
changing the function / range.
3.Select the maximum range and measure, if the value to be
measured is uncertain.
4.Always keep your fingers behind the finger guards on the
probe when making measurements.
WARNING
3) Measurement procedure
①
Shift the polarity reversal switch to
+
position.
②
Connect the black plug of the test lead to the
−
input
terminal and the red plug to the
+
input terminal.
③
Set the function/range selector to an appropriate DCV
range.
④
Apply the black test pin to the negative potential side of the
circuit to measure and the red test pin to the positive
potential side.
⑤
Read the pointer on V
・
A scale.
⑥
After measurement, remove the red and black test pins from
the circuit measured.
When the pointer moves to the
“−”
side, shift the polarity
reversal switch to the
“ − ”
position.
④
⑤
②
①
③
⑥
⑥
Battery
②
— 32 —