background image

2

Instruction Manual for SANUVAIR

®

 S100

1-

778-877-3454

www.

bluegoldlabs

.com

TABLE OF CONTENTS

 IMPORTANT SAFETY INSTRUCTIONS 

1

TABLE OF CONTENTS

2

ABOUT THE PRODUCT

3

COMPONENTS

3

How it Works

3

SETUP & INSTALLATION

3

What you will need

3

What’s included

3

Versatile Installations

4

Step by Step Setup & Installation - Ceiling-Mounted

4

Step by Step Setup & Installation - Wall-Mounted

6

OPERATION

7

How to Operate your Product

7

MAINTENANCE

8

How to Replace Lamp(s)

8

Step by Step Lamp Replacement

8

How to Clean your Product

9

Step by Step Filter Cleaning

9

STORAGE

10

ULTRAVIOLETS: UVV & UVC

10

ELECTRICAL RATINGS, POWER CONSUMPTION & AVAILABLE VOLTAGE

10

TROUBLESHOOTING

10

What you will need

10

Problems & Solutions Table

10

Step by Step UV Lamp Continuity Test

11

WARRANTY

12

CUSTOMER SERVICE

12

Содержание SANUVAIR S100GX

Страница 1: ...evail on those of this document and the installer agrees to conform to these at his own expense 7 Follow all the safety instructions outlined in this document and respect all local and national codes applicable 8 This unit contains a UV C emitter Unintended use of the unit or damage to the housing may result in harmful UV C radiation leaks UV C radiation may even in little doses cause harm to the ...

Страница 2: ...ep Setup Installation Ceiling Mounted 4 Step by Step Setup Installation Wall Mounted 6 OPERATION 7 How to Operate your Product 7 MAINTENANCE 8 How to Replace Lamp s 8 Step by Step Lamp Replacement 8 How to Clean your Product 9 Step by Step Filter Cleaning 9 STORAGE 10 ULTRAVIOLETS UVV UVC 10 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 10 TROUBLESHOOTING 10 What you will need 10 Problems...

Страница 3: ...n internal fan circulates air through the air purifier The SANUVAIR S100 is designed to treat up to 500 square feet of space per unit A Air inlet vent B Filter door with mesh C Security switch D Filter E UV Lamp F Fan G Unit cover H Air outlet vent SETUP INSTALLATION What you will need A utility knife to unpack all components a stepladder to reach the celling or wall properly a Phillips No 2 screw...

Страница 4: ... unit out of its box and install the support anchors required to support the unit by screwing them directly to the unit A Sliding door side near horizontal support bracket B Beveled side mesh angled support bracket Then lay the unit on a flat surface with the access doors facing up NOTE Keep box in case of return under warranty STEP 1 STEP 2 STEP 5 5 Install lamp Open the unit by sliding its cover...

Страница 5: ...he device support anchors against the tile and the ceiling support 11 Replace the cut part of the suspended ceiling tile to hide the opening Then right up against the unit install a 24 T bracket Your new SANUVAIR S100 is now ready to operate so you can enjoy great air quality for you and your colleagues 6 Install Filter While the unit cover is still open pull on the non mesh end to gain access to ...

Страница 6: ...ected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the UV lamp out from the cardboard sleeve Be sure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints NOTE Fingerprints on the lamp will negatively impact the UV output of the lamp STEP 3 STEP 4 STEP 5 STEP 6 5 Install lamp Open the unit by sliding its cov...

Страница 7: ... the fan settings are adjusted to your liking make sure to close the unit cover properly OPERATION How to Operate your Product If wired directly to a dedicated power source the SANUVAIR S100 will operate continuously If wired in parallel with other devices such as overhead lighting the SANUVAIR S100 will operate only when the circuit is energized The internal fan circulates air through the device ...

Страница 8: ...ption is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location NOTE Unit must be disconnected from the supply before replacing lamp 3 Prepare the new lamp Remove the contents from packaging Only after you have visually inspected the UV lamp should you break the security seal on the underside of the cardboard sleeve 4 Carefully slide the new UV lam...

Страница 9: ...oved for cleaning while the unit is installed on the ceiling or wall Another option is to remove the unit from the ceiling or wall and then access the filter with the unit lying on a flat surface with the access doors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover and pull on the non mesh end of the filter door to gain access to the filter loc...

Страница 10: ...HE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUSTOMER SERVICE FIRST DOING SO MAY VOID YOUR WARRANTY AND CAUSE PERSONAL INJURY OR DAMAGE TO THE PRODUCT TROUBLESHOOTING If your product is not working properly refer to the following What you will need A stepladder to reach to celling or wall properly and an ohmmeter Problem Possible...

Страница 11: ...ors facing up Besides this option is preferable for a wall unit 1 Open the unit by sliding down its cover to gain access to the lamp location 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have continuity When both sets of pins test good for continuity it can be assumed that the lamp is good ST...

Страница 12: ...o be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll free at 1 888 726 8869 or email info sanuvox com Please be sure...