background image

Sanuvox Technologies Inc, © 2020 All rights reserved. January 2022 EN v.1

Instruction Manual

Photos illustrating products are non contractual.

HRV

UV AIR PURIFIER

Residential or Commercial Model

Installation Date:  _______________   Installed by:  _________________
Installer Contact Info.:  _________________________________________

REGISTER 

YOUR WARRANTY

 

ONLINE AT 

www.sanuvox.com

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS PRODUCT.

Read and follow all instructions contained in the manual before using the product. Read the maintenance instructions before opening the UV unit 

or system. Failure to comply with these instructions may result in injuries or damage to the UV unit or system.

 NEVER EXPOSE EYES OR SKIN TO AN OPERATING UV LAMP. 

1. 

Installation and servicing of UV units or systems  (in an 

air conditioning system or not) can be hazardousOnly 

trained and qualified service personnel

 should install, 

repair or service equipment.

2.  Untrained personnel can perform basic maintenance 

functions  such  as  replacing  lamp(s)  and/or  filter(s).  All 

other operations should be performed by trained service 

personnel.

3.  The unit is not to be used by persons (including children) 

with reduced physical, sensory or mental capabilities, or 

lack of experience and knowledge.

 

 CAUTION: Unit is not a toy. Keep away from 

unsupervised children. Do not leave children unattended 

with the unit.

4.  DO NOT hang onto the UV unit or system

5.  Some UV units or systems could be heavy: Make sure 

you have a minimum of 2 people to safely move or install 

these UV units or systems, and make sure you adopt the 

most ergonomic position possible (use UV unit or system 

handles, if applicable).

 

 CAUTION:  Installing or maintaining heavy equipment, 

especially overhead, can cause back pain or other injuries. 

6.  When installing or servicing an overhead UV unit or system, 

be careful not to fall off the stepladder. Furthermore, make 

sure the UV unit or system latches are always in place to 

prevent falling parts.

 

 CAUTION: Some parts of some UV units and systems 

may open suddenly if the UV unit or system is installed 

high up without its locks.

7.  Units that are obviously damaged must not be operated.

8. 

 CAUTION: When working on the UV unit or system, 

observe precautions on the literature, tags and labels 

attached to the UV unit or system, and all other safety 

precautions considered as best practices in the HVAC 

industry, if applicable.

9.  When applicable, local regulation may comprise more 

restrictive  installation  and/or  certification  requirements. 

The aforementioned requirements prevail on those of this 

document and the installer agree to conform to these at his 

own expense.

10.  Follow all the safety instructions outlined in this document 

and respect all local and national codes applicable.

11.  All UV units or systems contain a UV-C source. Damage to 

the housing or unintended use of the UV unit or system may 

result in harmful UV-C leaks. UV-C may, even in little doses, 

cause harm to the eyes and skin.

12.  Never expose eyes or skin to an operating UV lamp. 

Therefore, before installing or performing maintenance 

on the UV unit or system, TURN OFF AND DISCONNECT 

the UV unit or system from all power sources (there 

may be more than one switch to disconnect) and also 

disconnect the HVAC system, is applicable.

 

 CAUTION: Electrical shock may cause injuries or 

possibly  death.  FIRST  AID  INSTRUCTIONS:  If  injured, 

consult a doctor.

13.  UV rays may damage certain types of filters (polymer or 

plastic); please keep the UV unit or system light away from 

shining directly on plastic.

14.  When installing or performing maintenance on the UV unit 

or system, it is recommended to wear safety gloves. In 

order to avoid reduced performance of lamp(s), do not 

touch lamp glass without gloves.

15.  Just like conventional fluorescent lamps, UV lamps contain 

a small quantity of mercury: if a lamp breaks, clean and 

dispose of with care. UV lamps can be disposed/recycled 

after use in the same way as any other fluorescent lamps. 

Contact and follow the specific instructions of your local 

and national authorities.

16. 

Use  only  specified  SANUVOX  branded  replacement 

UV lamps for your UV unit or system. Use of any other 

lamps will void your warranty and can result in damage to 

the UV unit or system.

17.  Sanuvox UV units or systems are not waterproof. DO NOT 

INSTALL OUTDOORS OR IN WET LOCATION unless 

specified otherwise.

18.  The use of a UV unit or system is a supplement to and 

not a substitute for standard infection control practices; 

users must continue to follow all current infection control 

practices, including those related to the cleaning and 

disinfection of environmental surfaces.

SAVE THESE INSTRUCTIONS

For any inquiries on a UV unit or system, contact :

Robert Smith 

146 Barr St, Saint-Laurent

Quebec, CA, H4T 1Y4 

1-888-726-8869 

[email protected]

Содержание HRV6

Страница 1: ...he UV unit or system and all other safety precautions considered as best practices in the HVAC industry if applicable 9 When applicable local regulation may comprise more restrictive installation and or certification requirements The aforementioned requirements prevail on those of this document and the installer agree to conform to these at his own expense 10 Follow all the safety instructions out...

Страница 2: ...hat s included 4 Step by Step Setup Installation 4 OPERATION 6 How to Operate your Product 6 How to Read the Signal Lights LED 6 MAINTENANCE 6 How to Replace Lamp 6 Step by Step Lamp Replacement 6 How to Clean your Product 8 STORAGE 8 ULTRAVIOLETS UVC 8 ELECTRICAL RATINGS POWER CONSUMPTION AVAILABLE VOLTAGE 8 TROUBLESHOOTING 8 What you will need 8 Problems Solutions Table 8 A Step by Step UV Lamp ...

Страница 3: ...ze your specific application please call SANUVOX at 1 888 726 8869 COMPONENTS How it Works Contaminated air enters the HRV parallel to the UV J Lamp thus increasing contact time with the UV energy Then the treated air circulates through the home A Aluminum Reflector Tube B Access Plate C Signal Lights LED D Ballast Box E Lamp Clamp inside the tube at the back of the access plate F Power Cord TECHN...

Страница 4: ...Step by Step Setup Installation 1 Prepare the HRV for installation Remove the contents from packaging Using a flat screwdriver turn the 4 access door screws so that you can separate the assembly ballast and access door from the reflector tube CAUTION Before installing or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more...

Страница 5: ... up the pins with the holes The connector will fit into position NOTE Too much force applied from the opposite endcap may break the lamp 6 Gently replace the assembly ballast access door and lamp in the reflector tube taking care not to hit the lamp Once the assembly is in place turn the 4 tightening screws using a flat screwdriver make sure that the access plate is securely attached to the tube S...

Страница 6: ...lure LED OFF No power or unit failure Lamp Ballast MAINTENANCE How to Replace the Lamp Replacing the lamp on the HRV is quick and easy Simply turn off the power source remove unit from duct remove and dispose of old lamp replace with new Sanuvox branded UV lamp replace unit in duct and turn power source back on See below for detailed step by step instructions CAUTION In order to avoid reduced perf...

Страница 7: ...ure to wear the cotton gloves included guaranteeing a clean lamp free from fingerprints Fingerprints on the lamp will negatively impact the UV output of the lamp 7 Once the UV lamp is installed reinstall the assembly in the reflector tube and plug in your unit STEP 7 5 While holding the porcelain end cap with 4 pins in the clamp carefully push the white connector onto the four pins The plug is des...

Страница 8: ...t 120 277 240VAC 50 60Hz The HRV6 has a power of 25 Watts and th HRV8 of 40 Watts See product label to confirm power consumption of your specific unit or system NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CUSTOMER SERVICE FIRST OR SEE YOUR WARRANTY DO NOT RETURN THE PRODUCT TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE PRODUCT OR TAMPER WITH ITS COMPONENTS WITHOUT CONTACTING CUS...

Страница 9: ...stalling or performing maintenance on the unit or system TURN OFF AND DISCONNECT the unit or system from all power sources there may be more than one switch to disconnect 2 Remove the UV lamp from the lamp socket by opening the retaining clamp 3 Using an ohmmeter place 1 probe on 1 of the 4 pins and by sensing the 3 remaining pins one should have continuity Make sure the 2 remaining pins also have...

Страница 10: ... SANUVOX will repair or replace this product if it is found to be defective in material or workmanship C This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual D This warranty does not cover the filters pre filters or other accessories if included except for material or workmanship defects Call us toll fr...

Отзывы: