Santon AH10/2.2 Скачать руководство пользователя страница 6

6

ELEMENT

NEON

RESET BUTTON

EARTH

POST

('STAT/CUT-OUT PLUGS DIRECTLY 

ONTO ELEMENT TERMINATIONS).

DOUBLE POLE

ISOLATING SWITCH

BROWN

BLUE

GREEN/YELLOW

MAINS 

SUPPLY

L
N

FIGURE 6:  WIRING DIAGRAM 'AC' ONLY.

IMPORTANT: THE COMBINED THERMOSTAT/CUT-OUT MUST BE PUSHED FULLY
                        HOME TO ENSURE CORRECT OPERATION OF THE CUT-OUT

COMBINED
THERMOSTAT
& CUT-OUT

THERMOSTAT
POCKET

ELEMENT
TERMINALS

FLARED END OF
THERMOSTAT
POCKET

CORRECT

INCORRECT

3.0 INSTALLATION - ELECTRICAL REQUIREMENTS

WARNING: This appliance must be earthed. It is suitable for a.c. supply only.         

Disconnect the electrical supply before removing the terminal cover. Installation 
must be in accordance with the current I.E.E. Wiring Regulations.
3.1

  The unit is supplied fitted with a 0.75m 3 core 1.5mm

2

 flexible cable. The electic

-

ity supply should be fused 13 Amp and be via a double pole isolating switch with 

a contact separation of at least 3mm in both poles. Refer to the schematic wiring 

diagram on page.

3.2 

The wires are colour coded as follows:

 

Green and Yellow  

EARTH   

(   )

 

Brown  

 

LIVE    

(L)

 

Blue  

 

NEUTRAL  

(N)

Содержание AH10/2.2

Страница 1: ...read and understand these instructions before starting work Please leave this leaflet with the user following installation PACK CONTENTS Heater Pressure relief valve Fixing screws and plugs Installation and User Instructions WARNING This water heater must only be installed by qualified persons 36005791 Issue 3 ...

Страница 2: ...W 15l 2 2kW Storage volume V litres 7 0 10 0 15 0 Mixed water 40 C V40 l 13 17 25 Load Profile XXS XXS XXS Energy Efficiency Class C C C Energy Efficiency 31 3 30 6 30 8 Annual electricity consumption kWh 589 603 599 Daily fuel consumption kWh 2 860 2 940 2 920 Thermostat setting 60 C Specific precautions that shall be taken when the water heater is assembled installed or maintained and disposed o...

Страница 3: ...ditions in 1 2 above cannot be met expansion must be accomodat ed using an Expansion Vessel To ensure all expansion takes place in the vessel a Non Rerturn Valve must also be fitted together with a Pressure Expansion Relief Valve see Figure 2 Use Accessory Pack ALK05 94970012 1 4 If the static supply pressure exceeds 4 1 bar 60p s i a Pressure Reducing Valve must be fitted to the cold main supply ...

Страница 4: ...T COLD DRAW OFF SERVICE VALVE COLD WATER MAINS 2 0 7L 2 8 10L OR 4 2 15L METRES IS REQUIRED FOR EXPANSION IN PIPEWORK FIGURE 1 FOR INLET WATER PRESSURES UP TO 4 1 BAR 60 P S I NO ADDITIONAL KITS USED COLD EXPANSION VESSEL NON RETURN VALVE NEAREST COLD DRAW OFF SERVICE VALVE COLD WATER MAINS FIGURE 2 FOR INLET WATER PRESSURES UP TO 4 1 BAR 60 P S I WHERE EXPANSION IN MAIN SUPPLY IS NOT POSSIBLE USI...

Страница 5: ...ricity gas or water below the surface of the wall 2 5 DO NOT install where the unit may freeze 2 6 Refer to the section IMPORTANT INSTALLATION POINTS to determine which valves and accessories are required Plumb in the valves in the sequence shown in the relevant Diagrams Figures 1 2 and 3 2 7 Both inlet and outlet pipes are clearly labeled The pipes are 15mm copper tube and are suitable for compre...

Страница 6: ...CT 3 0 INSTALLATION ELECTRICAL REQUIREMENTS WARNING This appliance must be earthed It is suitable for a c supply only Disconnect the electrical supply before removing the terminal cover Installation must be in accordance with the current I E E Wiring Regulations 3 1 The unit is supplied fitted with a 0 75m 3 core 1 5mm2 flexible cable The electic ity supply should be fused 13 Amp and be via a doub...

Страница 7: ...n met 5 3 Check that all water and electrical connections are tight 5 4 Open a hot water tap turn on mains water supply to the heater 5 5 Allow unit to fill and leave hot tap running for a short while to purge any air and flush out the pipework Close the hot tap and check the system for leaks 5 6 Manually test the operation of the Pressure Expansion Relief Valve and if fitted the Temperature Press...

Страница 8: ... unit through the outlet connection 7 3 Remove the terminal cover as described in Section Six 7 4 Disconnect the electrical terminations to the thermostat Disconnect earth links to the earthing stud 7 5 Remove the element plate assembly by unscrewing the five securing screws tapped jacking points are provided Remove any loose scale from the container Carefully clean off any scale from the element ...

Страница 9: ...re 95 614 274 Terminal cover 15 litre 95 614 275 8 0 MAINTENANCE SAFETY VALVES The Pressure Expansion Relief Valve and if fitted the Temperature Pressure Relief Valve should be regularly checked Manually operate the valves by either twisting the cap or lifting the lever Ensure water flows freely from the valve s and through the discharge pipes Ensure the valve s reseat correctly when released 9 0 ...

Страница 10: ... intermittently Presure Relief Valve Discharge of water from 1 Fit pack ALK05 94970012 see IMPORTANT INSTALLATION POINTS 2 Fit pack ALK04 94970011 see IMPORTANT INSTALLATION POINTS 3 Replace Pressure Relief Valve 4 Check and if necessary re charge Expansion Vessel pre charge pressure see Section 9 0 1 Expansion in mains not possible 2 Mains pressure exceeds 4 1 bar 60 p s i 3 Pressure Relief Valve...

Страница 11: ... of freezing when the heater is not in use for long periods during the winter months do not switch off the electrical supply and set the thermostat to its minimum position N B This will not protect other system pipework 13 2 The indicator light will be illuminated when the unit is heating 13 3 To ensure the heater continues to operate at its optimum performance it should be periodically maintained...

Страница 12: ...e unit has been used only for heating potable water The unit is not guaranteed against damage by frost and the inner container with integral immersion heater is not guaranteed against excessive scale build up This Guarantee in no way affects the statutory rights of the consumer The policy of Santon is one of continuous product development and as such we reserve the right to change specifications w...

Отзывы: