6
ELEMENT
NEON
RESET BUTTON
EARTH
POST
('STAT/CUT-OUT PLUGS DIRECTLY
ONTO ELEMENT TERMINATIONS).
DOUBLE POLE
ISOLATING SWITCH
BROWN
BLUE
GREEN/YELLOW
MAINS
SUPPLY
L
N
FIGURE 6: WIRING DIAGRAM 'AC' ONLY.
IMPORTANT: THE COMBINED THERMOSTAT/CUT-OUT MUST BE PUSHED FULLY
HOME TO ENSURE CORRECT OPERATION OF THE CUT-OUT
COMBINED
THERMOSTAT
& CUT-OUT
THERMOSTAT
POCKET
ELEMENT
TERMINALS
FLARED END OF
THERMOSTAT
POCKET
CORRECT
INCORRECT
3.0 INSTALLATION - ELECTRICAL REQUIREMENTS
WARNING: This appliance must be earthed. It is suitable for a.c. supply only.
Disconnect the electrical supply before removing the terminal cover. Installation
must be in accordance with the current I.E.E. Wiring Regulations.
3.1
The unit is supplied fitted with a 0.75m 3 core 1.5mm
2
flexible cable. The electic
-
ity supply should be fused 13 Amp and be via a double pole isolating switch with
a contact separation of at least 3mm in both poles. Refer to the schematic wiring
diagram on page.
3.2
The wires are colour coded as follows:
Green and Yellow
EARTH
( )
Brown
LIVE
(L)
Blue
NEUTRAL
(N)