background image

INSTALLATION INSTRUCTIONS

 HANDLE TRIM INSTALLATION

HANDLE TRIMS ARE READY FOR  DROP IN INSTALLATION.   

DO NOT DISASSEMBLE.

 

      Remove the valve body mounting hardware  from the valve body. 
      Hot valve assembly “Red” to be mounted on left.
      Cold valve assembly “Blue” to be mounted on right.
      -Apply a ring of silicone caulking around the handle hole on the sink 
     countertop.

 

      

       Slip valve through appropriate hole in sink or countertop.
       Align handle with respect to the spout and tighten valve body locknut
       until secure. Aim outlet hoses towards tee connector and attach securely
       to avoid leakage.

PAGE  02

POP-UP DRAIN INSTALLATION

A-   

Remove decorative drain  flange and drain plug from pop-up assembly. Apply a ring of silicone

     caulking to underside of decorative drain flange. 

DO NOT USE PLUMBERS’ PUTTY, WHICH CAN

     DAMAGE FINISH. 

 Insert threaded end of the assembly up from below sink. Completely thread

     drain body into decorative drain flange and align with ball rod hole facing back and tighten lock
     nut from below. Insert drain plug into decorative drain flange with adjustable eye-screw facing back.
     Attach ball rod washer and ball rod nut to horizontal ball rod and install into drain body. Do not over
     tighten, bal rod must operate freely. Slide lift rod and knob through spout and from below the lift rod 
     strap and tighten thumbscrew. Gently push the horizontal ball rod down to place the drain plug in the up
     position. Slip one leg of ball rod clip off horizontal ball rod and insert lift rod strap, reattach leg of ball
     rod clip.
     - Test pop-up for smooth operation and adjust if necessary.
   

Drain Plug

Drain Flange

Lift Rod Strap

Ball Rod

Drain Tube

Ball Rod Nut

Ball Rod Clip

Thumb Screw

Lock Nut

Washer

Gasket

Side hole

  Lift Rod

        

FLUSH THE LINE

 

After all the connections have been made from inlet supplies to angle stop, remove the aerator. Open  both hot and cold  valves. Slowly open angle

stop from below and flush the lines  for approximately  45 seconds to clean any debris.  Turn off the water and reinsert aerator.

WIDESPREADS

COLLECTION

SANTEC 

SANTEC 

 rubber washer

SANTEC 

SANTEC 

Fiber washer

Fiber washer

Brass lock nut

Brass lock nut

DO NOT USE PLUMBERS' PUTTY WHICH CAN DAMAGE FINISH