3. Specifications
Part Number:
4032230
Blower:
257 CFM @ 0.0" WG
206 CFM @ 0.2" WG
146 CFM @ 0.4" WG
Power:
530 Watts @ 80°F and 60% RH
Supply Voltage:
115 volt – 1phase – 60 Hz
Current Draw:
4.9 AMPS
Energy Factor:
4.2 L/kWh
Operating Temp.:
56°F Min., 95°F Max.
Sized for:
2,500 Sq. Ft. - Typical
Minimum Performance at 80°F and 60% RH
Water Removal:
105 Pints/Day
Efficiency:
8.8 Pints/kWh
Air Filter:
MERV-11
Size:
16" x 20" x 2"
Power Cord:
10', 110-120 VAC, Ground
Drain Connection:
3/4" Threaded NPT
Dimensions
Unit
Shipping
Width:
20.25"
24"
Height:
21.75"
28.25"
Length:
38"
42"
Weight:
140 lbs
160 lbs
4. Installation
4.1 Location
The Santa Fe Impact can be installed in a variety of
locations to meet the owner’s needs; other considerations
include:
1. Providing access to a 115 VAC power outlet
(10' power cord is provided).
2. Locating near a floor or other suitable drain
(8' drain hose included).
3. Mount 4" above drain.
4. Do not install the Santa Fe Impact with the exhaust
of the unit within 1' of a wall or obstruction. Do not
place the unit near open water.
4.1A No Ducting (fig. 1)
The simplest installation is to place the Santa Fe Impact with
no ducting. To ensure optimal performance, the air inlet and
the outlet of the unit must be at least 2' from walls and other
obstructions to air flow. Recirculation of outlet air into inlet
should be avoided as much as possible.
4.1B Ducted Return and Supply (fig. 2)
Dehumidification performance can be modified by adding an
return and/or supply duct to circulate air.
For optimal drying, use return duct to draw warm, moist air
from near the ceiling.
4.1C Remote Area, w/ Ducted Supply (fig. 3)
A simplified remote installation method than above uses
ducting between the Santa Fe Impact discharge and the humid
room; the Santa Fe Impact inlet draws air from the room in
which it’s located. This works well if there is an adequate air
flow path between the two rooms; e.g. high door undercut,
Santa Fe Impact XT OWNER’S AND INSTALLER’S MANUAL
3
Santa Fe Impact Installer’s & Owner’s Manual
Input of
Humid Air
Output of
Dehumidified Air
Front View
Input of
Humid Air
Front View
Output of Dehumidified Air
Front View