Items Included in Box:

• Santa Fe Rx Dehumidifier
• Santa Fe Rx Installation & Operation Instructions

Important Precautions

• The Santa Fe Rx is most effective if it is centrally located in the space to be dehumidified.
•   It is designed to be placed with its back 3' (ft.) or more from a wall (the air outlet is located at the lower portion of the 

back). This will reduce noise and the likelihood that discharge air will blow directly at someone. Avoid directing the 

discharge air at people. The dehumidifier should be used in the upright position.

•  Do not place the unit where curtains or debris can be drawn into the intake and restrict airflow. 
•  The device is designed to be installed indoors, ideally in a living space or basement, that is protected from rain and flooding. 
•  Do not operate in standing water or place the unit near open water. If used near a water source; be certain there is no 

chance the unit could fall into the water or get splashed and that it is plugged into a dedicated circuit and Ground Fault 

Circuit Interrupter (GFCI) protected outlet. 

•  The water removed by the Santa Fe Rx will be pumped through the 20' long hose coming from under its base. The hose 

(about the diameter of a TV coaxial cable) must be routed to a drain or outside. It can pump condensate 15' above the 

unit and can be extended.

•  Install the unit with enough space to access the rear panel, the discharge air flow side of the unit for maintenance and 

service.   

•  The top can serve as a light duty table (maximum load: 20 lbs.), but it must be removed periodically to check the air filter. 
• DO NOT use the dehumidifier as a bench or table.
•   DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted noise  

may result.

Location Considerations

•  Locate the dehumidifier near a suitable drain (drain 

hose included). Allow for proper drainage and 

routing of needed drain pipes. 

•  Locate the dehumidifier in an area where the cord’s 

length (10') easily reaches a 115 VAC electrical outlet 

with a minimum of a 15 Amp circuit capacity.

•  The unit is designed to operate while level. Failure 

to level the unit may result in leakage or improper 

drainage.

•  A flooded unit is not covered by warranty. 
•  Allow sufficient clearance to handle the unit’s overall 

dimensions as well as any optional return and supply 

ductwork to the unit. 

•  Allow sufficient clearance for filter removal and to 

prevent airflow obstruction.

•  Electrical service access will require the removal of  

the front panel. Allow sufficient clearance around  

the unit.

Dehumidifier Set Up

Содержание 4030440

Страница 1: ...ta Fe Rx is a great solution for a living room bedroom office space or anywhere that needs supplemental dehumidification Its clean design blends into any home or office d cor P N 4030440 Serial No Ins...

Страница 2: ...s 4 Dehumidifier Set Up 5 Items Included In Box 5 Important Precautions 5 Location Considerations 5 Drain Installation 6 Operation 7 Humidity Control Adjustment 7 Fan Operation 7 Defrost Cycle 7 Air F...

Страница 3: ...unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be installed indoors only No user se...

Страница 4: ...r MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 10 115 VAC Ground Drain Hose 3 16 ID x 20 15 Lift Capacity Internal pump included Refrigerant Type R410A Refer to manufacturers label for more info...

Страница 5: ...se coming from under its base The hose about the diameter of a TV coaxial cable must be routed to a drain or outside It can pump condensate 15 above the unit and can be extended Install the unit with...

Страница 6: ...greater to avoid overloading the pump Be sure the extension is at a down word slope to the drain Larger diameter hose is available from the factory or may be purchased from many hardware stores If the...

Страница 7: ...duce it to 45 50 RH A humidity meter is supplied upon return of the survey warranty registration card a meter is recommended to accurately monitor humidity levels Additional meters are available for p...

Страница 8: ...WEAR OR UNIT DAMAGE Front View TOP Front View FILTER TOP TOP FILTER Changing the Optional Filters An optional filter housing is available that attaches to the back of the machine and adds 6 1 2 to the...

Страница 9: ...9 1 800 533 7533 www Santa Fe Products com Santa Fe Rx Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Страница 10: ...pacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any further information...

Страница 11: ...frigerant type Compressor Capacitor Replacement This compressor is equipped with a two terminal external overload and a run capacitor but no start capacitor or relay WARNING SERVICING THE SANTA FE RX...

Страница 12: ...temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will p...

Страница 13: ...s not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Cus...

Страница 14: ...14 Santa Fe Rx Installation Operation Instructions www Santa Fe Products com 1 800 533 7533...

Страница 15: ...15 1 800 533 7533 www Santa Fe Products com Santa Fe Rx Installation Operation Instructions...

Страница 16: ...www Santa Fe Products com 1 800 533 7533...

Отзывы: