A unique dehumidifier solution that can be integrated into the living space.  
The 

Santa Fe Rx

 is a great solution for a living room, bedroom, office space,  

or anywhere that needs supplemental dehumidification. Its clean design blends  
into any home or office décor.

P/N: 4030440  Serial No.: 

Install Date:

Sold by: 

www.Santa-Fe-Products.com      1.800.533.7533

Installation & Operation Instructions

Содержание 4030440

Страница 1: ...ta Fe Rx is a great solution for a living room bedroom office space or anywhere that needs supplemental dehumidification Its clean design blends into any home or office d cor P N 4030440 Serial No Ins...

Страница 2: ...s 4 Dehumidifier Set Up 5 Items Included In Box 5 Important Precautions 5 Location Considerations 5 Drain Installation 6 Operation 7 Humidity Control Adjustment 7 Fan Operation 7 Defrost Cycle 7 Air F...

Страница 3: ...unit unattended ensure children do not have access to the equipment Do not allow children to play with or near the unit or in its air flow The unit is designed to be installed indoors only No user se...

Страница 4: ...r MERV 11 Standard Pleat Size 16 x 20 x 2 Power Cord 10 115 VAC Ground Drain Hose 3 16 ID x 20 15 Lift Capacity Internal pump included Refrigerant Type R410A Refer to manufacturers label for more info...

Страница 5: ...se coming from under its base The hose about the diameter of a TV coaxial cable must be routed to a drain or outside It can pump condensate 15 above the unit and can be extended Install the unit with...

Страница 6: ...greater to avoid overloading the pump Be sure the extension is at a down word slope to the drain Larger diameter hose is available from the factory or may be purchased from many hardware stores If the...

Страница 7: ...duce it to 45 50 RH A humidity meter is supplied upon return of the survey warranty registration card a meter is recommended to accurately monitor humidity levels Additional meters are available for p...

Страница 8: ...WEAR OR UNIT DAMAGE Front View TOP Front View FILTER TOP TOP FILTER Changing the Optional Filters An optional filter housing is available that attaches to the back of the machine and adds 6 1 2 to the...

Страница 9: ...9 1 800 533 7533 www Santa Fe Products com Santa Fe Rx Installation Operation Instructions MERV Rating Chart Air Filtration http www mechreps com PDF Merv_Rating_Chart pdf...

Страница 10: ...pacity If used in an area that may become wet a GFCI protected circuit is recommended The unit should not be used in areas prone to flooding Consult local electrical codes for any further information...

Страница 11: ...frigerant type Compressor Capacitor Replacement This compressor is equipped with a two terminal external overload and a run capacitor but no start capacitor or relay WARNING SERVICING THE SANTA FE RX...

Страница 12: ...temp Rh you should see some water production out of the hose within 30 minutes or so Note If the room temperature is 55 degrees or below and or in area of low relative humidity the dehumidifier will p...

Страница 13: ...s not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Cus...

Страница 14: ...14 Santa Fe Rx Installation Operation Instructions www Santa Fe Products com 1 800 533 7533...

Страница 15: ...15 1 800 533 7533 www Santa Fe Products com Santa Fe Rx Installation Operation Instructions...

Страница 16: ...www Santa Fe Products com 1 800 533 7533...

Отзывы: