11
1-800-533-7533 | www.Santa-Fe-Products.com
Santa Fe Rx Installation & Operation Instructions
Service
4022254 Accumulator
4021475
Air Filter, 2 x 16 x 20 Nominal
4024145
Air Filter, 4 x 20 x 32 Nominal, HEPA
(optional, requires kit, Item 3)
4023869
Air Filter Frame Kit (optional)
4028240
Blower, with Capacitor
4023871
Top Catch & Strike Set
4033032-03
Capacitor, 35 Mfd
4028231
Capillary Tube
4023604
Caster, Swivel, 2”
4028226-02
Condenser Coil
4029567
Compressor
4034605-01
Condensate Pump, Low Profile
4023661
Cord/Wire Harness
4025741
Defrost Control Thermostat
4021648
Defrost Control Mounting Clip
4033925-02
Evaporator Coil
4029510
Filter, Drier
4023747
Hose, Vinyl, .19 ID x20’
4027172
Humidity Controller
4021495
Knob, .25 Shaft
4023857
Label, Wiring Diagram
4023868
Metal Top
4029508
Low Pressure Control
1970010
Relay, 25A
4025560
Rocker Switch For Fan
Refrigerant Charging
If the refrigerant charge is lost due to service or a leak,
a new charge must be accurately weighed in. If any of
the old charge is left in the system, it must be recovered
before weighing in the new charge. Refer to the
unit nameplate for the correct charge weight and
refrigerant type.
Compressor/Capacitor Replacement
This compressor is equipped with a two terminal
external overload and a run capacitor, but no start
capacitor or relay.
WARNING!
SERVICING THE SANTA FE RX, WITH ITS HIGH PRESSURE REFRIGERANT SYSTEM AND HIGH VOLTAGE CIRCUITRY
PRESENTS A HEALTH HAZARD WHICH COULD RESULT IN DEATH, SERIOUS BODILY INJURY, AND/OR PROPERTY
DAMAGE. ONLY QUALIFIED SERVICE PEOPLE SHOULD SERVICE THIS UNIT.
Troubleshooting
CAUTION!
TROUBLESHOOTING SHOULD BE PERFORMED BY
A QUALIFIED HVAC TECHNICIAN.
Symptom
Possible Reason
Neither fan nor
compressor
running.
Dehumidification
is being called for.
Compressor is
not running.
Dehumidification
is being called for.
Fan is running.
1. Defective compressor
run capacitor.
2. Loose connection in
compressor circuit.
3. Defective compressor
overload.
4. Defective compressor.
5. Defrost thermostat open.
Compressor
cycles on and off.
Dehumidification is
being called for.
1. Low ambient
temperature and/or
humidity causing unit
to cycle through
defrost mode.
2. Defective compressor
overload.
3. Defective compressor.
4. Defrost thermostat
defective.
5. Dirty air filter(s) or air
flow restricted.
6. Defective fan or relay.
1. Dehumidifier unplugged
or no power to outlet.
2. Humidity control set
too high.
3. Loose connection in
internal or control wiring.
4. Defective compressor
relay.
Replacement Parts