OPERATION
16
Available parameters where 2T and 4T mode have been selected:
Tpr Gas pre-flow time
Unit S
Setting range 0.1
—
10
Factory setting 0.3
Is Starting current (only with 4T)
Unit A
Setting range 5
—
100%of main current Iw (DC)
;
10
—
100%of main current Iw (AC)
Factory setting 5
Tup Upslope time
Unit S
Setting range 0
—
10
Factory setting 0
Iw Welding current
Unit A
MAGIC AC GTIG-200P 5
—
200 (DC)
;
10
—
200 (AC)
Ib Base current
Unit A
MAGIC AC GTIG-200P 5
—
200 (DC)
;
10
—
200 (AC)
Important!
Only selectable when “pulse key” has been pressed.
Dcy Ratio of pulse duration to base current duration
Unit %
Setting range 5
—
100
Factory setting 5
Important!
Only selectable when “pulse key” has been pressed.
Fp Pulse frequency
Unit Hz
Setting range 0.5
—
200
Tpr
Is
Tup
Iw
Ic
Tpo
Tdown
Fp
Dcy
Ib
Iw