20
WHIRLSYSTEM
20
GB
3. INSTALLATION OF THE HYDROMASSAGE BATHTUB
3.1
TRANSpORT
The bathtub should be transported in the original, manufacturer’s packing only! While carrying, it is
forbidden to hold any massage elements. We shall bear no responsibility in case any leaks appeared
due to not obeying this rule!
3.2 PREPARATION OF THE INSTALLATION PLACE
The properly prepared installation place should have:
■
a leveled base
■
a 230 V mains supply socket secured with the In=30mAcircuit breaker (for example B16/0,03A)
■
ventilation allowing free air access to the parts and elements of equipment
■
a water sewage system
3.3
pROpER iNSTALLATiON
It should be done:
■
level the bathtub
■
place the bathtub ca 2mm from the wall in order to isolate vibrations, and fill the gap with sanitary
silicone or sealing tape.
3.4 ELECTRICAL CONNENCTION
The electrical installation should be done with accordance to all local electrical laws. Authorized
staff, having valid electrical authorizations, must carry out all the installation and measuring works. In
accordance to norms – bathtub with whirlpool system as the product with I class have to be connected
with electrical installation all the time by the bilpolar switch. For safety reasons, the bathtub power
cable should be connected to the electrical installation only through electrical connection protected by
a residual current device (RCD device) of the rated breaking point of 30mA, which will be in all poles
separated the system from the mains, leaving all contacts open to a width of at least 3mm.
RCD device should be controlled at least once a month ((by the push the button “TEST” on the RCD
– it should authomatically turn off the RCD)
The minimum cross-section of bathtub power cable is 3x1,5mm2.
In case of bathtub equipped in standard water heater (2kW), it is
important to use cable with minimum 3x2,5mm2 cross-section.
Permanently electrical connection to the bathtub should be
prepared in I zone (the unit is under the bathtub), in addition
it should be provide a combination of bathtub compensatory.
On the bathtub frame should be installed the marked terminal
expansion, which should be connected with expansion cable.
In case of built bathtub, pay attention should be done because
parts with active elements (with the exception of those elements
with low-voltage sate, i.e. not exceeding 12 V) cannot be
available to a person in bathtub.
The fact of connection with mains has to be recorded in the warranty card with the signature and stamp
by the authorized person what determines the validity of the guarantee.
400mm
300mm
S
S
Supply cable
3x2,5 mm²
L=2500 mm
Содержание CLASSIC 2 AIR
Страница 16: ...16 SYSTEMY HYDROMASAŻU PL ...
Страница 31: ...31 CLASSIC 2 31 GB ...