1/2
1
Art. T70
Hydroline
(h: mm 625)
PRE-INSTALLATION CHART
67100986500 2015.02
R 8
72
0
1800
1888 ±
1
808±
1
44
±
1
1886 ±
1
1886 ±
1
50
0
1850
1886 ±
1
430
730
530
85
85
min 20
0
2070
min 1105
85
min 20
0
720
1800
1900
800
1880
820
575
1380
J
I
1/2"
Facing for sunken
installation
Facing for flush
installation
ELECTRICAL CHARACTERISTICS
V
Hz
Power consumption
W
K074 (optional)
220 - 240
50/60
15
MY / MY-F
220 - 240
50/60
1000
HYDRAULIC CHARACTERISTICS
Water capacity (1)
lt
Emptying time (2)
min.
No. of Jets
Overflow water flow
rate
l/min.
400
11,5
32
-
8
Net Weight
kg
Floor Load
kg/m
2
Delivery Weight
kg
Delivery dimensions
cm
90
450
187
203 x 103 x 92
N.B. Measurements must be taken once the floors and walls are finished. For the
correct operation of the product, we recommend installing it on surfaces where
floor level heating is not used.
BATHTUB INSTALLATION
It is advisable to position the bathtub, make the necessary connections and
check the water-tightness of the system before building the perimeter walls.
Before building the perimetre walls, it is advisable to position the bathtub and
make the necessary connections. It is mandatory to create a removable panel
on the side of the tank (l), as shown in the relevant picture, which allows both
system inspection and ventilation; the panel must be provided with openings,
of at least 0,05 sqm in total, to allow system ventilation. Build the perimeter
wall also on taps and control side and always provide an inspection panel (J)
to carry out system maintenance operations, as shown in the picture. When
making the panel, follow the dimensions indicated in the diagram. The panel must
be fastened securely in place (e.g. with screws) so that a tool must be used to
remove it, as provided for by current safety standards. Envisage a clearance of at
least 40 cm in front of the removable panels.
(1) At overflow level - (2) Measurement taken at Teuco siphon outlet, with the bathtub filled up to overflow level.
Measurements in mm
- Connection of water mixed for ½” water sheet spout
- Electrical connection
I, J - Inspection and ventilation panels