6. Troubleshooting
To determine and search for anomalies it is essential to have this Operation and User Manual at hand.
•
Do not tip the device on its side over 60°at any time unless completely empty and dry.
Anomaly
Possible Cause
Remedy
Device does not work / does not
respond
•
Check power supply
•
Check fuses
•
Check correct insertion of cable
•
Ensure power supply to device
Fan does not work
•
Thermal motor sensor stops engine
(too high engine temperature)
•
Air-intake filter too dirty
•
Check engine, switch off and on
•
Set-up device once more
•
Clean or change filter
Liquid is not sprayed
•
Tank is empty
•
Nozzle is clogged
•
Fill liquid
•
Remove obstruction
Device does not start or stops
before finishing program
•
Cycle has been terminated abnormally
(e.g. power cuts)
•
Switch off and on again
•
Set-up device once more (4.5.2)
Device emits loud noises
•
Possible internal damages
•
Presence of foreign bodies in the fan
•
Switch off and unplug device,
call service technician
Device leaks liquid
•
Possible internal damages
•
Internal piping rupture or connections
leaking
•
Switch off and unplug device,
call service technician