background image

 

Sanosil Q-Jet Compact 

 
12 

 

 

 

 

4.5.2

 

Setting up the Device

 

Please read and follow important safety directions on page 6  
before use!

 

 

Switch on the device

 

(Display flashes)

 

 

 

Enter time in minutes through 

number buttons

 

 

(If mistake or change: renewed time 
input by pressing arrow button 

“left“)

 

 

 

 

Confirm time input by pressing Return/Enter

 

 

 

 

Start disinfection program by pressing return/Enter

 

(signal starts peeping)

 

 

 

Device starts in 20 seconds! (Count-down in action) Please leave room immediately!

 

 

 

During the course of the disinfection program the display shows the remaining time (Count-down).

 

 

 

At the end of the disinfection program the device makes a beeping noise 5 times.

 

 

 

Room re-entry minimum waiting-time begins (minimal 120 Minutes)

.

 

 

 

After the end of the waiting-time the room can be prepared for re-entry (please see 4.5.3) 

 

 

Shortening of waiting time: after a 

minimal waiting time of 120 minutes 

place a strong dehumidifier in the middle of 

the room and dehumidify room for at least 60 minutes or air room by opening a window or HVAC. Use full protection 
equipment when placing dehumidifier!

 

 

 

When room re-entry is required before treatment process is completed or to perform a H

2

O

2

 level check, proper personal 

equipment (PPE) including wraparound style goggles; respirator mask (filter class ABE1) filtering hydrogen peroxide (for 
example: 3M 4277 or 3M 7500 mask with 6057 filter) and gloves should be worn to safely enter the room.

 

 

 

 

 

 

 

 

 

 

 

INDICATION

 

A running disinfection program can be stopped anytime by pressing the number button 0!

 

Do only enter the room wearing protection mask, safety googles and gloves!

 

T:01

 

 

sym 

1     

abc  

2    

def 

 

ghi  

4     

jkl   

5    

mno 

 

pqrs 

7     

tuv  

8     

wxyz

9

  

 

 

 

 

 

 

 

 

 

 

 

 

ENTER

 

 

buttons

 

 

Содержание Q-Jet Compact

Страница 1: ...Sanosil Q Jet Compact 1 Operation and Maintenance Manual Sanosil Q Jet Compact Des M 56en Compact V2 English...

Страница 2: ...8 3 1 Technical Data 8 3 2 Parts and Functions 8 3 3 Package Contents 8 3 4 Q Jet Compact Accessories 8 3 5 Spare Parts 8 3 6 Recommended Equipment 8 3 7 Trolley optional 9 4 Getting Started and Oper...

Страница 3: ...ries Low risk Disregard can lead to medium or light injuries Disregard can damage thedevice Gives good advice for operating thedevice Further symbols will be explained thereafter 2 Safety DANGER Instr...

Страница 4: ...Sanosil Q Jet Compact 4 2 1 CE Declaration of Conformity manufacturer...

Страница 5: ...le liquids Do always and only use Sanosil disinfection liquids 2 4 Danger and Caution Warnings The device must be used in full compliance with this Operation and Maintenance Manual It is strictly forb...

Страница 6: ...an as needed basis depending on the volume of traffic and use Users should familiarize themselves with Q Jet operation by reading the Q Jet User Manual prior to first use It is essential that Q Jet u...

Страница 7: ...rical plug or parts are wet 8 Use only a Sanosil supplied electrical power cord 9 Take care to prevent water or other fluid from entering the device Should this occur allow to completely dry before us...

Страница 8: ...ent 0 20ppm for example Dr ger X am 5100 Gloves 3 Product Description 3 1 Technical Data Powerrequirements 220 240 V 50Hz Amperage max 5 A Operatingtemperature 5 C to 40 C Engine Power 800 W Engine ro...

Страница 9: ...place the device on top of trolley secure the device with the screw on the trolley WARNING Risk of crushing Hands and fingers can be crushed between device and trolley Do always wear device on handle...

Страница 10: ...ctrical connections carefully check that the voltage supplied is compatible with the voltage marked on the dataplate Insert power cord 2 in IEC power socket 4 3 Filling Remove tank cap 6 Fill disinfec...

Страница 11: ...x Width x Height of the room in meters and round it up to the next cubic meter Check relative humidity should not be lower than 50 Establish nebulization time room s volume x desired concentration 30...

Страница 12: ...the waiting time the room can be prepared for re entry please see 4 5 3 Shortening of waiting time after a minimal waiting time of 120 minutes place a strong dehumidifier in the middle of the room and...

Страница 13: ...n equipment if the H2 O2 Value isbelow the local maximum permissible value specified by the authorities Tip ON OFF 3 to switch off device INDICATION For transportation as well as for longer storage th...

Страница 14: ...eneral Visual control Checking operationality daily Components status of device s components integrity of components fluid loss sealings caps monthly Documentation Verification that all documentation...

Страница 15: ...gine temperature Air intake filter toodirty Check engine switch off and on Set up device once more Clean or change filter Liquid is not sprayed Tank is empty Nozzle is clogged Fill liquid Remove obstr...

Страница 16: ...ice should be noted please proceed as follows Download Customer Complaint Form from https www sanosil com de q jet and fill it carefully Call CleanService Group Ltd to obtain a Return Merchandise Auth...

Отзывы: