- 13 -
9‑1. Operating method Ⅰ
[In case the Detector is used without no‑voltage contact output・hold function]
Operations
Cautions
1 Confirm both power source switch
②
OFF and
hold switch
④
OFF.
2 Following the previous item 8. INSTALLATION
・
Connect the same numbered probe after
on page 10, correctly install the main body and
confirming the number of the main body.
the probe.
Insert the cable connector
⑮
in the receptacle
⑦
of the main body and the receptacle
⑯
of the probe and tighten it by turning the
connector ring.
3 Insert the power source cord
⑩
into a receptacle
・
Connection to a branch receptacle causes
within AC 100V to 240V.
malfunction.
4 Power source switch
②
ON.
・
The alarm lamp
⑥
will keep on going on under
・
The power source lamp
①
will go on and
hold switch
④
ON condition.
the color changes from red to green.
Hold switch OFF and confirm the alarm lamp
・
Confirm the buzzer switch
⑪
ON.
⑥
will go out.
・
The alarm buzzer
⑫
is gone for 2 to 3times,
・
The Detector can detect nothing while the
and it is possible to detect.
power source lamp
①
is red color. Confirm
・
Confirm that the alarm lamp
⑥
will go on
the operation for detection after changing the
with buzzer sound.
color from red to green.
The alarm buzzer
⑫
does not work when the
buzzer switch
⑪
OFF.
5 Turn the sensitivity adjusting dial
③
to the
・
When the sensitivity adjusting dial is at
right (clockwise) to set at level [10].
position
〔
0
〕,
the Detector can detect nothing.
6 Confirming the detecting ability
◆
In case the probe is installed in line:
After running the line, confirm the detecting
・
Objects to be inspected must be moved.
ability with the testing objects on which the
samples of breaking needles and iron pieces
desired to detect were stuck with tape etc.
When the surrounding noises cause
・
Before turning the sensitivity adjusting dial
malfunction, turn the sensitivity adjusting
③
, take noise sources away as possible.
dial
③
to the left (counterclockwise) until
Refer to 8, INSTALLATION on page 10.
malfunction stops.
After that, reconfirm the detecting ability
under running condition of the line.
◆
In case the probe is built-in into the
inspection table etc.:
Confirm the detecting ability with the testing
・
Objects to be inspected must be moved.
objects on which the samples of breaking
needles and iron pieces desired to detect were
stuck with tape etc. by moving those across
the detecting surface of the probe
⑬
.