![Sanken SAMCO-NS Series Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/sanken/samco-ns-series/samco-ns-series_instruction-manual_3998598035.webp)
-34-
Code
Function Name
Data Content
Setting
resolution
Factory
preset
1202
State display selection
1
:
No units
(
Multiple of F1203
)
2
:
Output voltage [V]
3
:
Dc voltage [V]
4
:
Active power [kW]
5
:
Apparent power [kVA].
6
:
Radiator Temperature [
℃
]
7
:
Command Speed [rpm]
8
:
PID1 feedback value [Hz]
9
:
PID2 feedback value [Hz]
10
:
VRF analog input value [Hz]
11
:
V/I analog input value [Hz]
14
:
Partial excitation current [A]
15
:
Partial torque current [A]
17
:
Setting pressure[MPa]
18
:
Command pressure[MPa]
19
:
Pressure feedback[MPa]
20
:
Regular pump switching calculating time
29
:
Command frequency [Hz]
35
:
Detect speed of rotation[rpm]
44
:
Target frequency[Hz]
45
:
Output frequency[Hz]
1
3
1203
Multiple for no unit
display
0
~
100
times
(
multiple of output frequency
)
0.01 times
1
1301
1
st
jump bottom frequency
0
~
600
[Hz]
0.01
[Hz]
0
1302
1
st
jump top frequency
0
~
600
[Hz]
0.01
[Hz]
0
1303
2
nd
jump bottom frequency
0
~
600
[Hz]
0.01
[Hz]
0
1304
2
nd
jump top frequency
0
~
600
[Hz]
0.01
[Hz]
0
1305
3
rd
jump bottom frequency
0
~
600
[Hz]
0.01
[Hz]
0
1306
3
rd
jump top frequency
0
~
600
[Hz]
0.01
[Hz]
0
1307
Auto alarm recovery
0
:
No Auto reset function
1
:
Auto reset function
1
0
1308
Instability elmination
0
~
20
1
※