Sanitron S17A Скачать руководство пользователя страница 20

20

USER ASSISTANCE

WARRANTY

 

We warrant that this product will be free from defects in material and workmanship for a period of one year from the date of 

shipment thereof or the product’s total rated life, whichever fi rst occurs. Within the warranty period we shall repair or replace such 
products, which are returned to us with shipping charges prepaid, and which are determined by us to be defective. This warranty 
will not apply to any product, which has been subjected to misuse, negligence, or accident; or misapplied; or modifi ed; or repaired 
by unauthorized persons; or improperly installed.

 

The Buyer shall inspect the product promptly after receipt and shall notify us at our main offi ce in writing of claims, 

including claims of breach of warranty, within thirty (30) days after the Buyer discovers or should have discovered the facts upon 
which the claim is based. Failure of the Buyer to give written notice of a claim within the time period shall be deemed to be a 
waiver of such claim.

 

The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties, expressed or 

implied, including warranties of merchantability and fi tness for a particular purpose, whether or not purposes or specifi cations 
are described herein. We further disclaim any responsibility whatsoever to the customer, or to any person, for injury to person, 
damage to, or loss of property or value caused by any product which has been subjected to misuse, negligence, accident; or 
modifi ed or repaired by unauthorized persons; or improperly installed.

 

Under no circumstances shall the Atlantic Ultraviolet Corporation

®

 be liable for any incidental, consequential or special 

damages, losses or expenses arising from the contract for this product, or in connection with the use of, or inability to use, our 
product for any purpose whatsoever.

P

ATENT

 N

OTICE

No attempt has been made to determine the patent status of applications illustrated or described in this publication. Inclusion 
in this publication of any design or method of use, which may be patented, is not to be construed as promoting or sanctioning 

unauthorized use.

Atlantic Ultraviolet Corporation

®

 

makes every effort to ensure that 
the 

SANITRON

®

 Ultraviolet Water 

Purifi ers are products of superior 
quality and workmanship. This manual 
describes the installation, operation 
and maintenance of the 

SANITRON

® 

Ultraviolet Water Purifi ers

Please read and become familiar with 
the contents of this manual before 
installing or using this unit. If after 
reading the manual you still have 
questions, or concerns, regarding the 
installation or use of this unit, contact 
our offi ces, weekdays between 8:30 am 
and 5:00 pm Eastern Time, at:

Atlantic Ultraviolet Corporation

®

375 Marcus Boulevard
Hauppauge, New York, 11788

Tel: 631.273.0500
Fax: 631.273.0771

E-mail: [email protected]
Website: www.ultraviolet.com
 www.buyultraviolet.com

PRODUCT REGISTRATION

 

Please REGISTER your product immediately - you can do this in a number of ways. Go online to Ultraviolet.com  and on the 
bottom left of each page either click on “Fill out Warranty Reg. Form on-line!” complete and hit submit or click on “Download 
a PDF of the Warranty Reg. card” which you can print, fi ll out and mail in. If you prefer to register over the telephone please call 
631-273-0500.

 

Atlantic Ultraviolet Corporation

®

 takes all possible precautions when packaging equipment to prevent damage. Carefully 

inspect and report all damage. Do not install damaged equipment. Follow all instructions on any labels or tags. Carefully inspect 
all packing materials before discarding to prevent the loss of accessories, mounting hardware, spare parts or instructions.

 

For your convenience, record the following information below. The model and serial number can be found on a label located 

on the 

SANITRON

®

 Ultraviolet Water Purifi er. Keep this manual, along with proof of purchase, handy when contacting our 

offi ces.

Purchased From:

Date:

Model:

Serial No.:

Содержание S17A

Страница 1: ...DXSSDXJH 1 D H PDLO LQIR XOWUDYLROHW FRP Extensive Product Information Available at ultraviolet com Document No 98 1377B9 August 2014 2014 Atlantic Ultraviolet Corporation Installation Operation Maintenance Read and Follow All Safety Instructions Save These Instructions Models S17A S23A S37C S50C Installation ULTRAVIOLET WATER PURIFIERS ...

Страница 2: ...ctions generally describe the installation operation and maintenance of the SANITRON line of water purifiers Models S17A S23A S37C and S50C Questions that are not specifically answerable by these instructions should be directed to the Factory Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage Carefully inspect and report all damages Do not in...

Страница 3: ... operate without proper electrical ground 12 Do not exceed water purifier s maximum rated flow capacity 13 Do not exceed maximum operating pressure of 100 PSI 14 Read and follow all notices and warnings on the water purifier 15 SAVE THESE INSTRUCTIONS This symbol pictorial is used to identify the need to wear protective gloves Caution indicates a POTENTIALLY hazardous situation which if not avoide...

Страница 4: ...is the product of ultraviolet intensity and the exposure time The operation of the SANITRON is as follows Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall Suspended microorganisms are exposed to the ultraviolet rays emitted by the germicidal lamp The translucent sight port or optional ultraviolet monitor provides visual indication of germici...

Страница 5: ...d in an area where any possible condensation or leakage from the water purifier any purifier accessory and or plumbing will not result in damage to the area surrounding the water purifier For added protection it is recommended that a suitable drain pan be installed under the purifier The drain pan must be plumbed to an adequate free flowing drain to prevent water damage in event of a leak There ar...

Страница 6: ...upply which is required when removing the quartz sleeve 7 Unions should be installed on both the inlet and outlet of the water purifier this will allow easy removal of the water purifier from the plumbing if required Apply Teflon tape to threads of inlet and outlet ports to ensure a tight seal 8 When all plumbing connections are complete allow water to enter the water purifier at a low flow rate u...

Страница 7: ...tatus Alarm produces a high pitched pulsed tone when the water purifier is no longer functioning due to lamp or power failure 4 Sure Flo Flow Control Valve Limits water flow to the rated capacity of the purifier The flow control valve is located in line prior to the water purifier and should be protected from ultraviolet exposure by the use of a 90 degree elbow fitting between the flow control val...

Страница 8: ...on or manganese Table 1 on Page 4 lists the maximum recommended concentration of these minerals in the water that passes through the ultraviolet purifier If you encounter difficulty due to deposits on the quartz sleeve your dealer will be able to recommend suitable pretreatment to reduce or eliminate the offending contaminant If quartz sleeve is clean clear then frequency of cleaning may be extend...

Страница 9: ... wire away from the socket 3 Carefully withdraw lamp approximately 2 inches from chamber while feeding lamp socket and lead wire on opposite end of chamber 4 While holding lamp end carefully remove lamp socket on end now exposed 5 Next carefully slide lamp back into chamber until approximately 2 inches of the lamp is exposed on the opposite end Hold lamp and remove lamp socket 6 Lamp should now be...

Страница 10: ... is easily accomplished using the dual action wiper mechanism 1 Lift wiper clip up and away from wiper rod 2 Grasp wiper knob and gently pull out away from the purifier until it reaches its stop 3 Push wiper back in toward the purifier until it reaches its second stop 4 Repeat steps 2 and 3 as necessary 5 Holding wiper in place return wiper clip and snap over wiper rod in front of the wiper lock s...

Страница 11: ... washer from static gland nut before proceeding 6 Carefully remove quartz sleeve from chamber NOTE It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber 7 Once the quartz sleeve is removed clean with alcohol or a mild non abrasive detergent Stubborn stains usually can be removed with a d...

Страница 12: ...16 wrench to loosen and remove the 1 4 nut from the head clamp 4 Withdraw chamber head and wiper assembly from the chamber 5 Any broken pieces of the quartz sleeve can now be removed through the open end of the purifier chamber Flush water through chamber being careful to remove all quartz fragments from the interior of the chamber 6 Carefully discard all pieces of the broken quartz sleeve 7 Inspe...

Страница 13: ...nspected and can be replaced if worn or damaged 8 Reassemble replacing the o rings quartz rod and securing in place with the quartz rod sensor probe cap Tighten the quartz rod sensor probe cap by hand only DO NOT USE HAND TOOLS Tightening with hand tools may damage the quartz rod or o ring seal 9 Reinstall sensor probe into the center fitting of the chamber and hand tighten 10 Slowly restore water...

Страница 14: ...e connections or fittings Tighten suspect connection or fitting or shut down purifier drain and remove fitting or connection Clean threads reapply thread sealing tape and reinstall Poor purifier performance AND OR Low UV intensity As indicated on optional GuardianTM Ultraviolet Monitor Quartz sleeve fouled Clean quartz sleeve see Quartz Sleeve Cleaning in the Maintenance Section Sensor Probe if eq...

Страница 15: ...in Plug 1 4 NPT 1 4 NPT 1 4 NPT 1 4 NPT Lamp Out Indicator Translucent Sight Port Translucent Sight Port Translucent Sight Port Translucent Sight Port Ultraviolet Monitor Optional Optional Optional Optional Flow Control Valve Optional Optional Optional Optional Audio Alarm Optional Optional Optional Optional Solenoid Valve Optional Optional Optional Optional Time Delay Mechanism Optional Optional ...

Страница 16: ...16 REPLACEMENT PARTS SANITRON MODELS S17A S23A Figure 9 Exploded View S17A S23A ...

Страница 17: ...1524D1 1 25 1523E1 16 Wiper Knob 1 25 1222 1 25 1222 17 Wiper Lock Spacer 1 25 1512A1 1 25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw No 8 x 3 8 long 4 50 1323 4 50 1323 22 Speed Nut 6 32 2 50 1314 2 50 1314 23A Ballast 120v 60Hz 1 10 0137 1 10 0137 23B Ballast 220v 50Hz 1 10 0136 1 10 0136 24 Screw Mo...

Страница 18: ...18 SANITRON MODELS S37C S50C Figure 10 Exploded View S37C S50C ...

Страница 19: ...25 1512A1 18 Wiper Clip 1 25 1507C1 1 25 1507C1 19 Dynamic Gland Wiper Lock 1 25 1510C1 1 25 1510C1 20 Drain Plug 1 27 1216 1 27 1216 21 Screw 1 4 20 x 3 8 long 4 50 1034 4 50 1034 22 Lock Washer 1 4 4 50 1321 4 50 1321 23 Flat Washer 1 4 4 50 1317 4 50 1317 24 Ballast Housing Cover 1 25 0394A 1 25 0350A 25 Screw No 8 x 3 8 long 8 50 1323 8 50 1323 26 Speed Nut 6 32 2 50 1314 2 50 1314 27A Ballast...

Страница 20: ... has been made to determine the patent status of applications illustrated or described in this publication Inclusion in this publication of any design or method of use which may be patented is not to be construed as promoting or sanctioning unauthorized use Atlantic Ultraviolet Corporation makes every effort to ensure that the SANITRON Ultraviolet Water Purifiers are products of superior quality a...

Отзывы: