16
EN
ENGLISH
Parameter
Function
System info
Sensor runtime in days
Number of full and partial flushes
Number of automatically triggered flushes
Number of intermittent flushes triggered and externally triggered flushes
Display of the min. and max. time in sec. between individual flushes
Display of the average daily number of full and partial flushes
Displace of code number and software ID:
Range test
Edge lighting flashes red, once right, once left.
During detection of the 0.8 m range, the full flush button shines in
blue
.
During detection of the 0.5 m range, the full flush button shines in
green
.
Range W setting
Is used for the automatic setting of the presence detection range. If this function is started, no
persons or objects may be within the desired detection range, max. 1.5 m.
Doors which project into the detection area must be closed immediately after activation (e.g. toi
-
let cabin), the flush panel is ready for use after 30 seconds and the room can be entered again.
Default setting
OK setting
All parameters are reset to the default setting.
Setting with service remote control DO-5.1 S
Set parameter
and confirm by
pressing the
OK key
Send setting
Confirm remote
control with
send OK
Open data recording
and menu
Select
parameter