General Instructions
Before installing and using your heating column ZEPHYR, please read
these instructions carefully and observe the following instructions :
SAFETY INSTRUCTIONS
The electrical connection must be carried out by a qualified electrician.
The installation must be protected by a 25 or 30 mA differential circuit-
breaker (NFC15-100 electrical safety standard). The power supply outage must be
of omnipolar type (phase and neutral cut-off).
The heating column ZEPHYR must be connected to the mains (230V AC 50/60Hz)
by an electrical circuit protected by an overcurrent circuit breaker16A placed in an
electrical distribution board.
A means of disconnection shall be provided in the fixed pipes in accordance
with the installation rules.
If the power cable is damaged, it must be replaced by a qualified electrician
(cable type H05VV - F 2 * 1 mm²).
The system complies with current standards (see technical data).
The heating column ZEPHYR is only suitable for indoor use. It is suitable for all the
rooms of the housing, including bathrooms thanks to a suitable protection (Double
insulation - Class II).