background image

3

Safety

SAVE THESE INSTRUCTIONS

WARNING: WHEN USING THIS UNIT, BASIC PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS

1.  READ AND FOLLOW ALL INSTRUCTIONS
2.  WARNING: Risk of accidental injury or drowning: Children or handicapped persons should not use pedicure spa without 

adult supervision.

3.  WARNING: To avoid injury, exercise care when using a pedicure spa.
4.  WARNING: Risk of electric shock: Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or 

television) to be within 5 ft (1.5 m) of this unit.

5.  DANGER: RISK OF ELECTRIC SHOCK: This unit should be grounded. Connect only to a dedicated 15 amp circuit that is 

protected by a Ground Fault Circuit Interrupter (GFCI). A GFCI should be provided by the electrician and should be 
tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. 
Power should be restored. If the GFCI fails to operate in this manner, there is a possibility of a ground fault, or defective 
GFCI. DO NOT USE THE UNIT. Have the problem corrected by a qualified service representative or an electrician before 
using.

6.  WARNING: Use the Pipeless™ Pedicure Bath only for its intended purpose: a fill and drain indoor appliance for foot and 

ankle hydromassage. DO NOT use attachments not recommended by manufacturer.

7.  RISK OF ELECTRIC SHOCK: Disconnect from the electrical supply before servicing.

WARNING

1.  DO NOT reach for any electrical object that has fallen into water. Unplug immediately.
2.  DO NOT drop or insert anything into any jet opening.
3.  DO NOT operate this unit without the complete jet assembly installed or without water filled 1 in (3 cm) above the jets .
4.  DO NOT overfill the basin.
5.  DO NOT stand on or in the basin, or on the foot rest.
6.  DO NOT leave this appliance unattended when in operation.
7.  Keep the electrical cord away from heated surfaces.
8.  Connect this appliance only to a properly grounded outlet (See Grounding Instructions on Page 4).
9.  To avoid injury, exercise care when entering or exiting the pedicure spa.
10.  It is important that you clean and disinfect the jets and basin after every use. Unless thoroughly cleaned after each use, 

bath residue will buildup within the jets and on the surface area of any whirlpool pedicure spa, which can promote the 
growth of infectious bacteria.

11.  Hydromassage should be pleasant and comfortable. Should you experience any pain or discomfort while using the 

pedicure spa, discontinue use immediately and consult your physician.

12.  Consult your physician if you are diabetic, have poor circulation, or if any area of your feet or legs is inflamed, has an 

open wound or if you have any other questions about whether you should be using hydromassage equipment.

13.  SANIJET recommends a qualified plumber and electrician install your Pipeless™ Pedicure Bath.
14.  Water supply temperature to the Pipeless™ Pedicure Bath MUST NOT exceed 106° F (41° C). Water temperature in excess 

of 106° F (41° C) may be injurious to users health. Check water temperature and adjust prior to use.

INSTALLER / OWNER BEARS ALL RESPONSIBILITIES TO COMPLY WITH ALL STATE AND LOCAL CODES WHEN

INSTALLING THIS PRODUCT. FAILURE TO COMPLY WITH THESE INSTRUCTIONS MAY VOID WARRANTY.

Содержание PIPELESS SFB2-S115-XX

Страница 1: ...Purity is Premium PIPELESS PORTABLE FOOT BATH WITH SEAL LESS JET TECHNOLOGY OWNER S MANUAL Models SFB2 S115 XX 115v 60Hz 2 Jet Dual Speed ...

Страница 2: ...ility for quick and easy system disinfection Please read and follow all of the instructions contained in this Manual before installing operating or maintaining your new SANIJET Pipeless Portable Foot Bath Before proceeding please take a few minutes to complete the warranty registration enclosed in your Owner s packet and submit it to SANIJET at the address provided on the form If you have question...

Страница 3: ...formation 1 Limited Commercial Warranty 2 Safety 3 Electrical 4 Features and Specifications 5 Operating Instructions 7 Dry Run Protection 8 How To Drain 9 Cleaning and Care 10 Troubleshooting 12 Table of Contents ...

Страница 4: ...t do not install the unit SANIJET s responsibility for shipping damage ceases upon delivery of the product in good condition to the carrier It is the responsibility of the recipient to inspect the packaging for damage Any damage claims must be filed with the carrier within 2 business days from receipt of shipment All returns will be refused unless accompanied by a Return Material Authorization RMA...

Страница 5: ...his warranty does NOT cover a metallic plated hardware light bulbs or fading from exposure to direct sunlight b failure damage or defect caused by any of the following after the product leaves SANIJET s factory mishandling abuse misuse neglect accident or natural disaster normal wear and use that does not affect the product s function failure to maintain the product as recommended by SANIJET See O...

Страница 6: ...en into water Unplug immediately 2 DO NOT drop or insert anything into any jet opening 3 DO NOT operate this unit without the complete jet assembly installed or without water filled 1 in 3 cm above the jets 4 DO NOT overfill the basin 5 DO NOT stand on or in the basin or on the foot rest 6 DO NOT leave this appliance unattended when in operation 7 Keep the electrical cord away from heated surfaces...

Страница 7: ...ot bath from the carton and retain the shipping carton and packing material to reuse in case service becomes necessary DO NOT lift the foot bath by its handle or electrical cord GROUNDING INSTRUCTIONS This unit must be grounded The integral GFCI should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored I...

Страница 8: ...gh Performance Ultra Quiet Pipeless Jets Advanced Seal less Technology Designed for Maintenance Free Use Complete Hygiene with Simple Five Minute Disinfection Protocol Two Piece Lid with Client Foot Rest for Comfort Rolling Casters and Easy to Use Handle Discharge Pump and Fill Hose Durable High Gloss Acrylic Construction in White or Biscuit ...

Страница 9: ...0 0 51 cm x Length 27 0 69 cm x Height 15 0 38 cm Material Structurally reinforced cast acrylic Operating Capacity 4 5 Gallons 17 L Approximate Ship Weight 42 lbs 19 kg Water Flow Rate 14 gallons per minute 53 L Electrical Requirements 115 VAC 60 Hz 15 amp dedicated GFCI service 10 ft 3 m 16 3 power cord included DIMENSIONS 27 69 cm 20 51 cm 15 38 cm ...

Страница 10: ...om splashing onto the floor 3 Verify that the unit s electrical cord is connected to a GFCI protected electrical outlet 4 To start or stop this appliance turn the dial switch to the ON or OFF position 5 Bath additives including oil based products can be used in a SANIJET Pipeless Pedicure Bath since their residue can be easily cleaned CAUTION Use only low foaming additives and do not use products ...

Страница 11: ...n back ON If the motor does not sense a load after 8 seconds it will shut off again for another 15 seconds The motor will repeat this sequence a total of 10 times before going into standby mode Resetting the motor requires cycling the main power to the motors OFF and then back ON unplug system and wait 5 seconds then plug power supply back in again SAFETY SHUTOFF SENSOR The Pipeless Pedicure Bath ...

Страница 12: ...y continue running the pump while removing it from the interior of the foot bath and place it in the sink or chosen draining area As soon as the pump and hose are both fully in the sink unplug the power cord to turn off the discharge pump Fresh water can be used to rinse out the tank during the draining procedure See Image 2 WARNING Do not leave the pump running in the draining area or in a dry fo...

Страница 13: ...requiring quick cleaning between treatments we recommend a second set of clean jet assemblies for quick replacement IMPORTANT Always refer to your state and local guidelines for cleaning requirements NEVER USE abrasive cleaners on any surface area After each use disinfect the system with the recommended disinfection procedures for maximum sanitation BEFORE USE check the jet assembly is properly in...

Страница 14: ...based cleaner Disinfect using a 5 1 water bleach solution Thoroughly rinse all cleaning solution residue with water Air dry Approved Cleaners DISPATCH Hospital Cleaner Disinfectant Clorox Disinfecting Wipes LYSOL Disinfectant Fantastik When using these cleaners we strongly recommend rinsing the surface with clean water in order to remove any cleaning residue HOW TO STORE THE FOOT BATH 1 Replace th...

Страница 15: ...n 3 Jet Assembly Alignment a Check jet assembly is locked in the 9 o clock or 3 o clock run position in the jet motor case b Ensure magnetic impeller rotor is correctly installed in the jet motor case c Inspect separator plate to ensure proper assembly in the jet escutcheon d Inspect separator plate to ensure magnets 2 are present and properly installed EXCESSIVE NOISE 1 Remove jet assembly escutc...

Страница 16: ...120125 SANIJET Customer Service Department Toll Free 877 934 0477 Toll Free Fax 214 352 0348 E mail info sanijet com 6200 Maple Avenue Dallas Texas 75235 sanijet com ...

Отзывы: