30
6.1.4.2.
Automatic reversal
By default, the reversal time is set at four hours. Your salt water chlorinator indicates this reversal
in the same way as for a forced reversal.
Note: You can change the reversal time on your salt water chlorinator.
TO DO SO, YOU MUST CONTACT YOUR POOL PROFESSIONAL
Find the programming DIP on the card.
Figure 9
Set the switches to programme the desired time (see Figure 10 below).
12h00
8h00
4h00
24h00
Inter 2
ON
OFF
ON
OFF
Inter 1
ON
ON
OFF
OFF
Figure 10
6.1.5.COVER OR SHUTTER FUNCTION
6.1.5.1.
Objective
If you use a pool cover system (following the French law of January 2003 on pool safety), when
the pool is covered the appliance’s production must be reduced to prevent overproduction. Any
overproduction may cause discoloration to the liner, corrode equipment and cause unpleasant
effects for swimmers.
6.1.5.2.
Activating the function
There are two modes for activating this function:
• Manual mode.
• Automatic mode.