Installation Instructions
The KBox C-103-NGSF comes with attached wall mount brackets. The available mounting key
holes (Figure 21, pos. 1 and pos. 3) of the wall mounting brackets allow the unit
attaching to a wall of a fire resistant enclosure.
Please observe the following safety and installation instructions:
Whenever possible, unpack or pack this product only at EOS/ESD safe work stations.
Where a safe work station is not guaranteed, it is important for the user to be
electrically discharged before touching the product with his/her hands or tools.
This is most easily done by touching a metal part of the system chassis.
Do not handle this product out of its protective enclosure while it is not used for
operational purposes unless it is otherwise protected.
Prior any installation work ensure that there are no live wires on the installation
site
Do not handle the device if there is any damage visible.
Do not operate the KBox C-103-NGSF with foreign objects inside the chassis.
Further do not insert any retrieval device into the device while it is connected to
power.
Kontron rejects all liability for any and all damages resulting from operation of
the unit with foreign objects inside the chassis.
The KBox C-103-NGSF has to be installed and operated only by trained and qualified
personnel.
The KBox C-103-NGSF system is designed for usage within control cabinets only.
Only personnel with appropriate qualifications, trainings and authorization are
permitted to install and work with the Kontron KBox C-103-NGSF.
This device shall only be installed in or connected to systems that fulfill all
necessary technical and specific environmental requirements.
The KBox C-103-NGSF system is designed to be operated in vertical position with
attached mounting brackets as shown in Figure 4 and Figure 5. It is not allowed to
install the KBox C-103-NGSF as a stand-alone (desktop) device.
Do not remove the wall mounting brackets.
The unit must be placed such that there is sufficient space in front of it for
connecting the cables to the I/O interface connectors and for operating the power
button.
Leave sufficient free space around the unit to prevent the device from possibly
overheating!
To ensure proper operation, we recommended free space as specified below:
above and below: 100 mm (3.937")
left and right: 50 mm (1.96").
It must be observed that all ventilation openings are not covered/obstructed by
objects.
The KBox C-103-NGSF must be firmly attached to a clean flat and solid mounting
surface. Use proper fastening materials suitable for the mounting surface. Ensure
that the mounting surface type and the used mounting solution safely support the
load of the KBox C-103-NGSF and the attached components.
Please follow the local/national regulations for grounding.
The voltage feeds must not be overloaded. Adjust the cabling and the overcurrent
protection to correspond with the electrical figures indicated on the type label.
The type label is located on the right side of the system.
It is recommended that the last cable attached to the system should be the power
cable! Refer to the section 7.3 “DC Power Plug Terminal” and chapter 8/ “Starting
Up”.
The unit is to be connected only to internal Ethernet networks without exiting a
facility and being subjected to TNVs.
External circuits connected to the device shall be SELV/PELV (galvanic seperated
from mains by double or reinforce insulation).
Содержание KBOX C-103-NGSF
Страница 7: ...KBox C 103 NGSF User Guide Rev Proof of Concept www kontron com 7 ...
Страница 17: ...KBox C 103 NGSF User Guide Rev Proof of Concept www kontron com 17 ...
Страница 28: ...KBox C 103 NGSF User Guide Rev Proof of Concept www kontron com 28 3 3 1 X101 X201 Power Input Connectors ...
Страница 77: ...KBox C 103 NGSF User Guide Rev Proof of Concept www kontron com 77 ...