background image

520-222-000

1/04   Rev C

Model S30 Metallic Design Level 1   Page 10

TROUBLESHOOTING
Possible Symptoms:

Pump will not cycle.

Pump cycles, but produces no flow.

Pump cycles, but flow rate is
unsatisfactory.

Pump cycle seems unbalanced.

Pump cycle seems to produce
excessive vibration.

What to Check: 

Excessive suction lift

in system.

Corrective Action: 

For lifts exceeding

20 feet (6 meters), filling the pumping
chambers with liquid will prime the pump
in most cases.

What to Check: 

Excessive flooded

suction in system.

Corrective Action: 

For flooded

conditions exceeding 10 feet (3 meters)
of liquid, install a back pressure device.

What to Check: 

System head exceeds

air supply pressure.

Corrective Action: 

Increase the inlet air

pressure to the pump. Most diaphragm
pumps are designed for 1:1 pressure
ratio at zero flow.

What to Check: 

Air supply pressure or

volume exceeds system head.

Corrective Action: 

Decrease inlet air

pressure and volume to the pump
as calculated on the published
PERFORMANCE CURVE. Pump is
cavitating the fluid by fast cycling.

What to Check: 

Undersized suction line.

Corrective Action: 

Meet or exceed

pump connection recommendations
shown on the DIMENSIONAL
DRAWING.

What to Check: 

Restricted or undersized

air line.

Corrective Action: 

Install a larger air line

and connection. Refer to air inlet
recommendations shown in your pump’s
SERVICE MANUAL.

What to Check: 

Check ESADS, the

Externally Serviceable Air Distribution
System of the pump.

Corrective Action: 

Disassemble and

inspect the main air distribution valve,
pilot valve and pilot valve actuators.
Refer to the parts drawing and air valve
section of the SERVICE MANUAL.
Check for clogged discharge or closed
valve before reassembly.

What to Check: 

Rigid pipe connections

to pump.

Corrective Action: 

Install flexible

connectors and a Warren Rupp
Tranquilizer® surge suppressor.

What to Check: 

Blocked air exhaust

muffler.

Corrective Action: 

Remove muffler

screen, clean or de-ice and reinstall.
Refer to the Air Exhaust section of your
pump SERVICE MANUAL.

What to Check: 

Pumped fluid in air

exhaust muffler.

Corrective Action: 

Disassemble pump

chambers. Inspect for diaphragm rupture
or loose diaphragm plate assembly. Refer
to the Diaphragm Replacement section
of your pump SERVICE MANUAL.

What to Check: 

Suction side air leakage

or air in product.

Corrective Action: 

Visually inspect all

suction side gaskets and pipe
connections.

What to Check: 

Obstructed check

valve.

Corrective Action: 

Disassemble the wet

end of the pump and manually
dislodge obstruction in the check
valve pocket. Refer to the Check
Valve section of the pump SERVICE
MANUAL for disassembly instructions.

What to Check: 

Worn or misaligned

check valve or check valve seat.

Corrective Action: 

Inspect check valves

and seats for wear and proper seating.
Replace if necessary. Refer to Check
Valve section of the pump SERVICE
MANUAL for disassembly instructions.

What to Check: 

Blocked suction line.

Corrective Action: 

Remove or flush

obstruction. Check and clear all suction
screens and strainers.

What to Check: 

Blocked discharge line.

Corrective Action: 

Check for obstruction

or closed discharge line valves.

What to Check: 

Blocked pumping

chamber.

Corrective Action: 

Disassemble and

inspect the wetted chambers of the
pump. Remove or flush any obstructions.
Refer to the pump SERVICE MANUAL
for disassembly instructions.

What to Check: 

Entrained air or vapor

lock in one or both pumping chambers.

Corrective Action: 

Purge chambers

through tapped chamber vent plugs.
PURGING THE CHAMBERS OF AIR
CAN BE DANGEROUS! Contact the
Warren Rupp Technical Services Group
before performing this procedure. Any
model with top-ported discharge will
reduce or eliminate problems with
entrained air.

If your pump continues to perform

below your expectations, contact your
local Warren Rupp Distributor or factory
Technical Services Group for a service
evaluation.

WARRANTY

Refer to the enclosed Warren Rupp

Warranty Certificate.

Содержание S30

Страница 1: ...n Valve w Stroke Indicator Servicing 19 Solenoid Shifted Air Valve Drawing 20 Solenoid Shifted Air Valve Parts List 20 Solenoid Shifted Air Distribution Valve Option 21 Diaphragm Service Drawing with Overlay 22 Diaphragm Service Drawing Non Overlay 22 Diaphragm Servicing 23 Overlay Diaphragm Servicing 23 Actuator Plunger Servicing 24 Check Valve Servicing 25 Check Valve Drawing 25 Optional Muffler...

Страница 2: ......

Страница 3: ...ayer Long mechanical flex 275 F 40 F life Excellent abrasion resistance 135 C 40 C Virgin PTFE Chemically inert virtually impervious Very few chemicals are known to react chemically with PTFE molten alkali metals turbulent liquid or gaseous fluorine and a few fluoro chemicals such as 220 F 35 F chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures ...

Страница 4: ...0VAC Pulse Output Kit P3 Intrinsically Safe 110 120VAC Pulse Output Kit P4 Intrinsically Safe 220 240VAC Pulse Output Kit SP Stroke Indicator Pins Check Diaphragm Check Non Wetted Shipping MODEL Pump Pump Valve Design Wetted Check Valve Valve Material Porting Pump Pump Kit Weight Brand Size Type Level Material Materials Seat Options Options Style Options Options lbs kg S30B1ABBANS000 S 30 B 1 A B ...

Страница 5: ...1 2 3 4 5 6 7 0 20 40 60 80 100 120 140 160 180 200 900 800 700 600 500 400 300 200 100 0 220 240 U S Gallons per minute Displacement Per Stroke 94 gallons 3 56 liters Flow Capacity 0 to 235 gallons per minute 0 to 889 liters per minute 120 204 140 238 100 PSI 6 8 Bar 80 PSI 5 44 Bar 60 PSI 4 08 Bar 20 PSI 1 36 Bar Air Inlet Pressure 40 PSI 2 72 Bar 30 20 25 10 15 5 9 1 6 7 6 3 4 5 1 5 NPSHR METER...

Страница 6: ...Bolt Circle Suction Port 3 150 LB FF ANSI Flange Ø3 4 4 Holes Equally Spaced On A Ø6 Bolt Circle 1 NPT Exhaust Port For Optional Piping Exhaust Air In Submerged Applications Air Inlet 3 4 NPT Pulse Output Kit Aluminum Sound Dampening Muffler Encapsulated Muffler Stainless Steel Metal Muffler DIMENSION B C D E 15 3 4 16 1 32 31 3 4 4 1 8 18 29 32 35 11 16 30 27 32 4 7 32 19 35 25 32 Mesh Muffler 16...

Страница 7: ...s Equally Spaced On A Ø160mm Bolt Circle Discharge Port 80 DIN 10 Bar Flange Ø19mm 8 Holes Equally Spaced On A Ø160mm Bolt Circle Metric Dimensions S30 Metallic Flanged Dimensions in Millimeters Dimensional Tolerance 3mm Pulse Output Kit Aluminum Sound Dampening Muffler Encapsulated Muffler Stainless Steel Metal Muffler DIMENSION B C D E 400 407 806 105 481 906 808 107 483 908 Mesh Muffler 422 422...

Страница 8: ...r Of Gravity Suction Port 3 NPT 1 3 4 To Center Of Gravity Standard Encapsulated Muffler 1 NPT Exhaust Port For Optional Muffler Styles Or Piping Exhaust Air In Submerged Applications Air Inlet 3 4 NPT Pulse Output Kit Aluminum Sound Dampening Muffler Encapsulated Muffler Stainless Steel Metal Muffler DIMENSION B C D E 15 3 4 16 1 32 29 31 32 2 11 32 17 9 64 32 1 16 30 3 16 2 9 16 17 23 64 32 9 32...

Страница 9: ...ction And Discharge Ports Are Available With 3 BSP Tapered Connection Air Inlet 3 4 NPT Standard Encapsulated Muffler 1 NPT Exhaust Port For Optional Muffler Styles Or Piping Exhaust Air In Submerged Applications Pulse Output Kit Aluminum Sound Dampening Muffler Encapsulated Muffler Stainless Steel Metal Muffler DIMENSION B C D E 400 407 761 60 435 815 767 66 441 821 Mesh Muffler 437 437 425 A ...

Страница 10: ...educes vibration and strain to the pumping system A Warren Rupp Tranquilizer surge suppressor is recommended to further reduce pulsation in flow AIR SUPPLY Air supply pressure cannot exceed 125 psi 8 6 bar Connect the pump air inlet to an air supply of sufficient capacity and pressure required for desired performance When the air supply line is solid piping use a short length of flexible hose not ...

Страница 11: ...TA80 Surge Suppressor 020 051 000 Filter Regulator 020 051 001 Lubricator Available from Warren Rupp CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped in the event of a diaphragm failure INSTALLATION GUIDE Top Discharge Ball Valve Unit ...

Страница 12: ...r exhaust muffler Corrective Action Remove muffler screen clean or de ice and reinstall Refer to the Air Exhaust section of your pump SERVICE MANUAL What to Check Pumped fluid in air exhaust muffler Corrective Action Disassemble pump chambers Inspect for diaphragm rupture or loose diaphragm plate assembly Refer to the Diaphragm Replacement section of your pump SERVICE MANUAL What to Check Suction ...

Страница 13: ...e 28 WARNING IMPORTANT Read these safety warnings and instructions in this manual completely before installation and start up of the pump It is the responsibility of the purchaser to retain this manual for reference Failure to comply with the recommendations stated in this manual will damage the pump and void factory warranty WARNING Airborne particles and loud noise hazards Wear ear and eye prote...

Страница 14: ...r coded RED 361 Buna N 363 Viton Flurorel Color coded YELLOW 364 E P D M Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 370 Butyl Rubber Color coded BROWN 371 Philthane Tuftane 374 Carboxylated Nitrile 375 Fluorinated Nitrile 378 High Density Polypropylene 379 Conductive Nitrile 405 Cellulose Fibre 408 Cork and Neoprene 425 Compressed Fibre...

Страница 15: ...520 222 000 1 04 Rev C Model S30 Metallic Design Level 1 Page 13 ...

Страница 16: ...75 217 000 MIDSECTION CONVERSION KIT Replaces Aluminum Midsection with Cast Iron Components Air Inlet Cap Intermediate Bracket Inner Chambers and Inner Diaphragm Plates HARDWARE KITS 475 197 330 Zinc Plated Capscrews Washers and Hex Nuts 475 197 115 Stainless Steel Capscrews Washers and Hex Nuts PULSE OUTPUT KITS For use with 530 010 000 mufflers or piped exhaust 475 198 001 DC Kit 475 198 002 DC ...

Страница 17: ...2 518 143 156 Manifold Suction 1 518 143 156E Manifold Suction 3 BSPT 1 518 143 010 Manifold Suction 1 518 143 010E Manifold Suction 3 BSPT 1 518 143 110 Manifold Suction 1 518 143 110E Manifold Suction 3 BSPT 1 518 143 112 Manifold Suction 1 518 143 112E Manifold Suction 3 BSPT 1 23 518 144 156 Manifold Discharge 1 518 144 156E Manifold Discharge 3 BSPT 1 518 144 010 Manifold Discharge 1 518 144 ...

Страница 18: ...wrench or socket remove the eight hex capscrews items 1 F that fasten the end caps to the valve body Next remove the two end caps items 1 E Inspect the two o rings items 1 D on each end cap for damage or wear Replace the o rings as needed Remove the bumpers items 1 C Inspect the bumpers for damage or wear Replace the bumpers as needed Remove the spool part of item 1 B from the sleeve Be careful no...

Страница 19: ...cks or damage Replace gasket if needed Step 2 Disassembly of the air valve Using a 7 16 wrench or socket remove the eight hex capscrews items 1 F that fasten the end caps to the valve body Next remove the two end caps items 1 E Inspect the two o rings items 1 D on each end cap for damage or wear Replace the bumpers as needed Remove the bumpers items 1 C Inspect the bumpers for damage or wear Repla...

Страница 20: ...alve 1 1 C 132 029 552 Bumper 2 1 D 165 096 551 Cap Muffler 1 1 E 165 098 147 Cap End 2 1 F 530 028 550 Muffler 1 1 G 560 020 360 O Ring 8 1 H 675 044 115 Ring Retaining 2 1 J 710 015 115 Screw SelfTapping 4 1 K 210 008 330 Clip Safety 1 1 M 560 001 360 O Ring 2 For Pumps with Alternate Mesh Sound Dampening Mufflers or Piped Exhaust 1 031 147 000 Air Valve Assembly 1 includes all items on 031 146 ...

Страница 21: ...nants Remove the sleeve if needed and replace with a new sleeve and spool set item 1 A Step 3 Re assembly of the air valve Install one bumper item 1 C and one end cap item 1 E with o rings item 1 G and 1 M into one end of the air valve body item 1 B Install one retaining ring item 1 H into the groove on the same end Insert the safety clip item 1 K through the smaller unthreaded hole in the endcap ...

Страница 22: ...1 39 241 001 000 Connector conduit 1 241 003 000 Conduit Connector with 1 Suppression Diode DC Only 40 170 029 330 Capscrew Hex HD 5 16 18 x 1 50 4 41 618 051 150 Plug 2 For Explosion Proof Solenoid Valve Connector not required for explosion proof coil coil is integral with valve 37 893 098 001 Solenoid Valve NEMA 7 9 24VDC 1 893 098 002 Solenoid Valve NEMA 7 9 24VAC 12VDC 1 893 098 003 Solenoid V...

Страница 23: ...utilized to cycle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric power is turned off the solenoid shifts and the pressurized chamber is exhausted while the other chamber is pressurized By alternately applying and removing power to the solenoid the pump cyc...

Страница 24: ...22 000 1 04 Rev C Model S30 Metallic Design Level 1 Page 22 Diaphragm Service Drawing Non Overlay Diaphragm Service Drawing with Overlay 32 25 15 13 6 28 17 16 29 9 14 24 24 32 25 15 13 6 28 17 29 9 14 24 24 ...

Страница 25: ...se one of the two methods for holding the inner diaphragm plate that was described in prior note in step 3 Use a torque wrench to tighten the diaphragm assembly together to 50 ft lbs 67 79 Newton meters Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate for stress relaxation in the clamped assembly Step 5 Installing the diaphragm assemblies to the pump...

Страница 26: ... rings if necessary Apply a light coating of grease to each o ring and re install the plungers in to the bushings Push the plungers in as far as they will go To remove the bushings item 7 first remove the retaining rings item 31 by using a flat screwdriver NOTE It is recommended that new retaining rings be installed Step 3 Re install the pilot valve assembly into the intermediate assembly Be caref...

Страница 27: ... is removed the check valve components can be seen Inspect the check balls items 2 for wear abrasion or cuts on the spherical surface The check valve seats item 34 should be inspected for cuts abrasive wear or embedded material on the surfaces of both the external and internal chambers The spherical surface of the check balls must seat flush to the surface of the check valve seats for the pump to ...

Страница 28: ...o hold it in place Configuration B 530 010 000 Mesh Muffler screws directly into the Air Valve Body This muffler is equipped with a metal element Configuration C 530 027 000 Sound Dampening Muffler screws directly into the Air Valve body This muffler is equipped with a porous plastic element Configuration A Configuration B and C Note the pump is built with a metal muffler for static electric dissi...

Страница 29: ...cm diameter Reducing the pipe size will restrict air flow and reduce pump performance When the pumped product source is at a higher level than the pump flooded suction condition pipe the exhaust higher than the product source to prevent siphoning spills See illustration 3 at right CONVERTINGTHE PUMP FOR PIPINGTHE EXHAUST AIR The following steps are necessary to convert the pump to pipe the exhaust...

Страница 30: ...014 330 self tapping screws Then insert the leak detectors into the bottom port in the inner chambers Configuration B To be used with either of the muffler options or if your exhaust is piped away You will need to mount the terminal box to the 612 185 552 mounting plate using the 2 710 014 330 self tapping screws Then mount the mounting plate directly to the air valve body using the 4 710 009 115 ...

Страница 31: ... a PLC The Pulse Output Kits mount directly onto the Muffler Cap on the Air Distribution Valve Assembly or onto the Air Distribution Valve Assembly when the threaded exhaust port or an auxiliary muffler is being used See the individual kits listed on the Pump Repair Parts List for further information RuppTech Pulse Output Kit Drawing Options Exhaust Port or Auxiliary Muffler Setup Integral Muffler...

Страница 32: ...he local electrical code for detailed grounding instruction and the type of equipment required Grounding The Pump Take action to prevent static sparking Fire or explosion can result especially when handling flammable liquids The pump piping valves containers or other miscellaneous equipment must be grounded WARNING One eyelet is installed to a true earth ground Requires a 5 16 or 8mm maximum diame...

Отзывы: