S&P TERMOWEB Скачать руководство пользователя страница 31

31

EN

11. DECOMMISSIONING / RECYCLING

EEC regulations and our commitment to future generations require us to recy-

cle materials; we ask you to please put all remaining packaging in the proper 

recycling bins and take any devices replaced to the nearest waste management 

service. If your device is also labelled with this symbol, do not forget to take the 

replaced appliance to the nearest Waste Manager.

12.  INFORMATION ON DISMANTLING, RECYCLING OR DISPOSAL OF THE PRODUCT 

AT THE END OF ITS SERVICE LIFE

If the different TERMOWEB CONTROLS are scrapped, the necessary provisions for the dispo-

sal or recycling of the materials and components must be followed.
List of the main materials:

•  LCD screen

•  Bodies in PP, ABS plastic.

•  Electronic boards with tin.

•  Electrical wires. 

13. TECHNICAL SUPPORT

The large S&P Official Services Network guarantees adequate technical support.  If you ob-

serve any anomaly in the device’s operation, please contact any of the mentioned services, 

where your request will be duly dealt with. Any manipulation that’s not strictly necessary for 

the installation of the device carried out by anyone outside S&P’s Official Services forces us to 

cancel your warranty. If you have any questions about S&P products, contact the Post-sales 

Service Network in Spain or your usual distributor in the rest of the world. You can check our 

WEBPAGE to find your closest one: www.solerpalau.com

Содержание TERMOWEB

Страница 1: ...ES EN CONTROLES TERMOWEB TERMOWEB CONTROLS...

Страница 2: ...El TERMOSTATO TERMOWEB permite programar y controlar la tempe ratura de su hogar MEDIDOR TERMOWEB El MEDIDOR TERMOWEB mide el consumo el ctrico de su hogar Le ayuda a conocer c mo y cu ndo est gastand...

Страница 3: ...stalaci n puede tardar unos minutos en ser accesible desde la aplicaci n m vil si no se desea esperar desconectar y conectar la alimentaci n de la CENTRALITA TERMOWEB 2 1 LUCES DE LA CENTRALITA La CEN...

Страница 4: ...alida siguientes deben de estar abiertos 123 P 3000 TCP 3 TERMOSTATO TERMOWEB Retire su antiguo termostato y desconecte los cables que vienen de la caldera Separe el pa nel frontal de la base pared pr...

Страница 5: ...ara conectarlos en las conexiones NC y COM ATENCI N Riesgo de explosi n en caso de sustituci n de la bater a por una de tipo inco rrecto Desh gase de las bater as usadas de acuerdo con las instruccion...

Страница 6: ...ci n de los iconos de la pantalla 3 1 4 Cambio de pantallas Desde la pantalla principal del termostato se puede acceder a las distintas pantallas que nos permitir n configurar su funcionamiento 3 1 5...

Страница 7: ...las y se elige el modo y con la tecla OK se confirma Modos disponibles AUTO el termostato sigue la temperatura establecida en la programaci n Manual el termostato sigue la temperatura de consigna que...

Страница 8: ...pulsa OK para poder modificarlo con las teclas y Una vez realizados los cambios se vuel ve a pulsar OK para confirmarlos Los distintos par metros seleccionables son Fecha y hora modifica el a o mes d...

Страница 9: ...n del firmware del termostato C7 Funcionamiento del rel Se define si el contacto del rel funciona como NC normalmente cerrado o NO normalmente abierto 4 MEDIDOR TERMOWEB Apague la alimentaci n de su...

Страница 10: ...entes de sistema de que disponga acceda al por tal web en http control termoweb net y seleccione Crear una cuenta nueva y rellene los campos que se indican en el formulario Usuario introduzca su corre...

Страница 11: ...aplicaci n a las siguientes tiendas de aplicaciones 7 EMPAREJAMIENTO 7 1 EMPAREJAMIENTO CENTRALITA TERMOWEB Una vez haya conectado a Internet la CENTRALITA TERMOWEB y la haya dado de alta en la web el...

Страница 12: ...stra do en el peque o pulsador situado en la parte superior del MEDIDOR TERMOWEB Puede comprobar que est emparejado observando el LED del MEDIDOR TERMOWEB 7 3 1 Estados del led del medidor Termoweb No...

Страница 13: ...radio parpadeando y el s mbolo fijo Si el termostato est asociado pero no consigue comunicarse con la centralita no se muestran las ondas de radio y tanto la antena como el s mbolo parpadean En cuanto...

Страница 14: ...uipo de calor Protecci n bater a baja OFF Protecci n antiagarrotamiento bomba OFF Contacto de rel NO normalmente abierto Programa semanal por defecto D as laborables CONFORT de 7h 9h de 13h 15h 18 23h...

Страница 15: ...SPR14 15mA 10 2 CENTRALITA TERMOWEB Colocaci n sobremesa o pared Alimentaci n adaptador de corriente externo micro USB 5V 500mA Dimensiones 80x80x22 mm Conector RJ45 para conexiones Ethernet Frecuenci...

Страница 16: ...materiales y componentes Listado de los principales materiales Pantalla LCD Carcasas de pl stico PP ABS Placas electr nicas con esta o Cables el ctricos 13 ASIST NCIA T CNICA La extensa Red de Servic...

Страница 17: ...allows you to set and control the tempe rature of your home TERMOWEB METER The TERMOWEB METER measures your home s electricity consump tion It helps you find out how and when you are spending on elec...

Страница 18: ...reconnect the TERMOWEB CONTROL BOX s power supply 2 1 LIGHTS ON THE CONTROL BOX The TERMOWEB CONTROL BOX shows its status by means of its LED lights Green off orange flashing intermittently for one s...

Страница 19: ...racket by pressing the lower tab and pulling away from the wall bracket in the direction shown in the illustration Screw the wall bracket to the wall and connect the boiler cables to the COM and NO te...

Страница 20: ...explosion risk Dis pose of used batteries in accordance with the recycling instructions 3 1 HOW THE TERMOWEB THERMOSTAT WORKS 3 1 1 Temperature settings Different settings can be made on the thermost...

Страница 21: ...ndicators Keypad lock Low battery Ambient temperature Type of degrees displayed Weekdays Advanced configuration Communication status indicator Configuration menu Hourly daily schedule Operating modes...

Страница 22: ...the home screen We choose the mode with the and keys and confirm with the OK key Modes available AUTO the thermostat follows the temperature set in the programme Manual the thermostat follows the setp...

Страница 23: ...e able to change it with the and keys Once we have made the changes we press OK again to confirm them The different settings we can select are Date and time changes the year month date day of the week...

Страница 24: ...nti blocking protection Turns on the heating every Monday from 00 00 to 00 10 C6 Thermostat firmware version C7 Relay operation We select whether the relay contact operates as NC normally closed or NO...

Страница 25: ...e installed all the system components you have go to the website at http control termoweb net and select Create a new account and complete the fields indicated in the form User Password Password confi...

Страница 26: ...ollowing app stores 7 PAIRING 7 1 PAIRING WITH TERMOWEB CONTROL BOX Once you have connected the TERMOWEB CONTROL BOX to the Internet and registered it on the website http control termoweb net you have...

Страница 27: ...on the little button located on the top part of the TERMOWEB METER You can check it s paired by observing the TER MOWEB METER s LED 7 3 1 Termoweb meter LED statuses Not paired LED off Correctly paire...

Страница 28: ...hermostat is associated but fails to communicate with the control box the radio waves are not displayed and both the antenna and the symbol flash As soon as com munication is recovered the control box...

Страница 29: ...mally open Default weekly programme Working days COMFORT from 7 00 to 9 00 from 13 00 to 15 00 from 18 00 to 23 00 Weekend COMFORT from 9 00 to 23 00 10 TECHNICAL CHARACTERISTICS 10 1 TERMOWEB THERMOS...

Страница 30: ...l Power supply external micro USB power adapter 5 V 500 mA Dimensions 80x80x22 mm RJ45 connector for Ethernet connections Communication frequency 868 MHz Operating temperature 0 C to 60 C Storage temp...

Страница 31: ...ecycling of the materials and components must be followed List of the main materials LCD screen Bodies in PP ABS plastic Electronic boards with tin Electrical wires 13 TECHNICAL SUPPORT The large S P...

Страница 32: ...S P SISTEMAS DE VENTILACI N S L U C Llevant 4 Pol gono Industrial Llevant 08150 Parets del Vall s Barcelona Espa a Tel 34 93 571 93 00 www solerpalau com Ref 1441341 1...