30
EN
• Surface mounting, or on top of a switch box
• Switching capacity
• With resistive load 6 A/230˜
• With inductive load Cos Ø = 0.6 2 A/230˜
• Type of connection: 1.5 mm² screw terminals
• Type of disconnection: micro disconnection
• No. of automatic cycles (A) per automatic action: 30000
• CTI 175
• Electrical stress period: long
• Action type 1
• Additional characteristics: class B
• Continuous operation
• Type of environment: clean
• Surge immunity category: II
• Inflammable category: D
• Magnet CISPR14: 15 mA
10.2. TERMOWEB CONTROL BOX
• Placement on table or wall
• Power supply: external micro USB power adapter, 5 V 500 mA.
• Dimensions: 80x80x22 mm
• RJ45 connector for Ethernet connections
• Communication frequency: 868 MHz
• Operating temperature 0 °C to 60 °C
• Storage temp. -20 °C to 85 °C
10.3. TERMOWEB METER
• Placement in DIN rail. 1 rail module required.
• Power supply 200-260 V~ 50 Hz
• Consumption 0.90 W
• Communication frequency: 868 MHz
• Measurement: CAT II
• Voltage and Current, up to 80 A-AC
• Instant active power
• Cumulative active energy
• Error: <3%
• Operating temp.: 0 °C to 60 °C
• Storage temp.: -20 °C to 85 °C
• Resistance to impact: IK06
• Measuring probe:
− External current transformer with measuring range between 0 and 80 A AC. Connection
with 3.5 mm jack.
− Cable measuring capacity: Ø 9 mm, maximum commercial section 70 mm
2
.
Содержание TERMOWEB
Страница 1: ...ES EN CONTROLES TERMOWEB TERMOWEB CONTROLS...