− 8 −
7. INSTALLING SP-46N (CLAMP BAR STACKER)
(OPTIONAL PART NO. : 40149301)
Clamp bar stacker is delivered in the
state that it is fixed in the frame at the
time of delivery with the clamp bar
stacker mounted. It is necessary to
change the installing position to the nor-
mal using position.
①
Remove stacker fixing plate
❶
.
②
Turn the whole stacker in the direction of the
arrow and take it out from inside of the frame.
③
Change stacker turning shaft
A
section to
stacker base hole
B
.
At this time, take care to prevent the stacker cord, the air piping, etc. from being caught.
In addition, insert the stacker rotating shaft into the hole in the stacker base until the bottom of
the base is reached.
④
Lock the whole stacker with hinge
❷
.
⑤
Insert safety bar
❸
in direction
C
as illustrated
in the figure. Fix the safety bar at the position
where it is in parallel with the floor surface.
At this time, confirm that air is being
supplied.
C
❸
❷
❶
A
B
Stacker in the operation state (with the air supply)
If the aforementioned situation occurs,
stop the air supply to bring the stacker
back to the state shown in the left figure
"Stacker in the setup state (without the
air supply)".
Then, start supplying the air after check
-
ing to make sure that the stacker is in
the setup state.
In the case of power interruption due to
a power failure, etc., the folding opera
-
tion of the stacker can get out of order.
Be aware that this can give rise to a risk
that the hand is caught in the stacker.
Do not put hands in the area surrounded
by the safety bar.
Stacker in the setup state (without the air supply)