3.3.1 Setting Horizontal Circle
STEPS
DISPLAY
Turn to the third page of the function key
bar, and press Set Hz.
【
Measure
】
1/4
PtID
:
A1
R.HT
:
1.000m
HZ
:
34°40’09”
V
:
55°06’54”
Ⅰ
:
20.546 m Mem.
:
1.254 m
Set Hz
TILT
BEEP
│←
Current horizontal angle will be displayed.
a. To set the current horizontal angle as
the orientation, press SET.
b. To set other value as the orientation,
press ENT to input an angle value.
c.
To set the orientation to 0
°00’00”,
press 0SET.
【
Hz Settings
】
HZ
:
34°40’09”
0SET
SET.
3.3.2 Setting the Instrument Height and Prism Height
After setting the relative coordinate of the occupied point according to origin point,
the instrument automatically converts and displays the prism point Coordinate
based on the origin and occupied point.
STEPS
DISPLAY
Turn to the second page of the function
key bar, and press SetStn.
【
Measure
】
1/4
PtID
:
A1
R.HT
:
1.000m
HZ
:
34°40’09”
V
:
55°06’54”
Ⅰ
:
20.546 m Mem.
:
1.254 m
SetStn
EDM
↓
Input
the
PtID,
instrument
height,
description, coordinates, and press SET.
【
Setting Station
】
PtID
:
OCC1
INS.Ht
:
1.000m
Desc
:
34°40
′
09
″
Y0/E0
:
55°06
′
54
″
Ⅰ
X0/N0
:
20.546 m
Mem.
H0
:
1.254 m
SET