Sandia 80-6001 Скачать руководство пользователя страница 7

2.0   Grounding Instructions Continued

This electric equipment is for use on a normal 120 volt circuit. It has a grounded plug that 

looks like the plug illustrated in (Fig A). A temporary adapter, such as illustrated in (Fig B 

and C), may be used to connect this plug into a two-pole receptacle, as shown in (Fig B), 

if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet (Fig A) can 

be installed by a qualified electrician. The green color rigid ear lug or the like extending 

from the adapter must be connected to a permanent ground such as a properly grounded 

outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw.

3.0   Care of your Flood Pumper

Treat your machine as you would any other high grade, precision made product.  

Dropping, unreasonable bumping across thresholds and other misuses may result in a 

damaged unit which will not be covered under warranty.
After each use, wipe the extractor body, accessories and power cord with a slightly damp 

cloth. When not in use, the remove the power cord and hoses. Stored in a dry area. 
WARNING: DO NOT use the flood pumper as a dry vacuum. It is for wet pick-up 

only. Failure to do so with damage the pump and VOID your warranty.

4.0   Set-Up and Operation

DO NOT USE ON WET SURFACES. DO NOT EXPOSE TO RAIN. STORE 

INDOORS.
This machine comes with (1) 25-foot, 12/3-gauge safety power cord, (1) 25-foot, 

2” blue auto-dump hose and (1) 25-foot 1-1/2” vacuum hose. 

4.1    Connect the Auto-Dump Hose

The auto-dump hose is a 25-foot, 2” blue hose.
•  Locate the QD dump port located on the front of the machine’s base.
•  Push the end of the auto-dump hose onto the QD dump port. Close the latches on each 

side of the hose so that it is securly locked to the dump port. Note: only one side of 

this hose will properly fit onto the dump port. Do not force.

•  Place the other end of the hose in a commode or drain connected to a sanitary sewer 

system.

4.2    Connect the Vac Hose

The vacuum hose is a 25-foot, 1-1/2” vacuum hose.
•  Locate the vacuum hose port located on the front of the machine next to the switch 

panel.

•  Push the vacuum hose onto the end of the vacuum hose port.
•  Next, attached a tool of your choosing to the end of the vacuum hose.

6.0   Maintenance Continued

6.2    Clean Auto-Dump Pump-Out and Recovery Tank 

         Continued

6.3    Clean Dump Valve

The dump valve, located on the back of the machine, has a track inside of it. Open the 

dump valve and check the track for build-up. This build-up could prevent the dump valve 

from closing and cause leaking. Use a toothbrush to clean the track of the dump valve.

6.4    WD-40 Vacuum Motor

Should moisture ever enter the vacuum motor, completely drain the recovery tank, open 

the recovery tank lid, remove the vacuum float assembly, turn on the vacuum motor and 

spray a burst of WD-40 into the standpipe. Continue to run the vacuum motor for at least 

three (3) minutes.
To prevent moisture from damaging the vacuum motor during storage, empty the 

recovery tank and store with the lid open.

7.0   Storing your Flood Pumper

Store your Flood Pumper in temperatures over 40 degrees Fahrenheit. To prevent 

moisture from damaging the vacuum motor during storage, empty the recovery tank and 

store with the lid open. Store in an upright position in a dry area.

24-Gallon Sniper Flood Pumper (7)

(10) 24-Gallon Sniper Flood Pumper

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание 80-6001

Страница 1: ...ump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period Service labor charges are covered for one 1 year from the date of purchase when performed by a manufacturer authorized service provider Labor is only provided by authorized service centers If an authorized service center is not near you it is the purchaser ...

Страница 2: ... or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 15571 Container Lane Huntington Beach CA 92649 Visit our website at www sandiaplastics com Register your machine online at www sandiaplastics com registration aspx Mail to Ultimate Solutions Corporate Offices 15571 Container Lane Huntington Beach CA 92649 See reverse side for Warranty Infor...

Страница 3: ...urer must issue an RMA Sheet containing approved labor time and replacement parts Do not send parts or equipment back to manufacturer without an RMA number and approval No labor will be paid for nor part costs paid for or reimbursed that have not been previously approved by the manufacturer All warranty work must be approved and authorized to qualify and appropriate warranty procedures must be fol...

Страница 4: ...r reimbursement TheoriginalpurchasermustcontactthemanufacturertofollowcorrectRMA warrantyprocedures They must include a copy of the RMA Sheet enclosed in the box with the returned item No returns shall be authorized unless the proper RMA procedures are followed It is the responsibility of the distributor to repair the client s equipment as soon as possible The manufacturer charges a 25 restocking ...

Страница 5: ...lood pumper before connecting disconnecting or working on the machine This equipment must be connected to a properly grounded outlet only see grounding instructions The extension cord provided with this unit is 1 25 foot 12 3 gauge safet power cord and MUST be used with this unit to ensure grounding protection Turn off all controls before unplugging Make sure the on off switch is in the off positi...

Страница 6: ...ug is necessary DO NOT connect the grounded wire to a flat bed terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electrical Code 8 0 Trouble Shooting Guide CAUTION Always disconnect the power cord before servicing equipment WARNING Never operate ...

Страница 7: ... of the machine s base Push the end of the auto dump hose onto the QD dump port Close the latches on each side of the hose so that it is securly locked to the dump port Note only one side of this hose will properly fit onto the dump port Do not force Place the other end of the hose in a commode or drain connected to a sanitary sewer system 4 2 Connect the Vac Hose The vacuum hose is a 25 foot 1 1 ...

Страница 8: ...al injury or death Regular maintenance is required to keep your flood pumper in proper working condition Failure to properly maintain your machine could VOID warranty Thoroughly clean all equipment and accessories after each use Operation Interval Clean Vacuum Float Assembly Screen Daily After Each Job Clean Auto Dump Pump Out Recovery Tank Daily Clean Dump Valve Daily 6 1 Clean Vacuum Float Assem...