Sandia 80-6001 Скачать руководство пользователя страница 2

(2) 24-Gallon Sniper Flood Pumper

Dear Valued Client,

Congratulations on the purchase of your 24-Gallon Flood Pumper! The world of 

carpet  and floor cleaning is becoming more high-tech and competitive and we strive 

to provide you with the most innovative products. Our Flood Pumper is yet another 

example of this, bringing a new dimension to flood restoration and cleaning with its 

cutting-edge features, quality and value.
Please review this manual paying careful attention to the Safety Instructions section.  

Keep in mind that any unnecessary damage, neglect or abuse of this machine will void 

your warranty. You can be confident that simple maintenance will ensure that your 

Flood Pumper provides quality performance for many years to come.
If warranty questions arise, please consult your manual or contact your distributor.  

Should you have any questions regarding maintenance, replacing parts or ordering 

parts, please call an authorized distributor.
Before you begin using your flood pumper, thoroughly review the Owner’s Manual.
Again, congratulations on the purchase of your 24-Gallon Flood Pumper!

Questions or Comments?

Phone: 

714-901-8400

Toll Free: 

800-983-5834

Fax: 

714-901-8404

Ultimate Solutions Corporate Offices:

15571 Container Lane, Huntington Beach, CA 92649

Visit our website at:

 www.sandiaplastics.com

Register your machine online at: 

www.sandiaplastics.com/registration.aspx

Mail to:

Ultimate Solutions Corporate Offices

15571 Container Lane

Huntington Beach, CA 92649

See reverse side for Warranty Information.

Make a copy of this card for future reference.

Copyright © 2015 Ultimate Solutions | Sandia Products. All Rights Reserved.

WARRANTY REGISTRATION

Please take a moment to register your machine. Fill out the 

information below and mail back to Sandia Products immediately.

The warranty starts on the purchase date by the original purchaser subject to proof 

of purchase. This Machine Registration Card must be completed and returned 

immediately at the time of purchase. If proof of purchase cannot be identified, 

the warranty start date is ninety (90) days after the inventory stocking date at the 

distributor’s warehouse.

Your machine may also be registered online at:

www.sandiaplastics.com/registration.aspx

Machine Model                                                   Purchase Date                                        

Motor Type                                                            Serial No.                                                   

Place of Purchase                                                                                                                      

Shipped To                                                                                                                                    

Your Name                                                             Phone                                                         

E-mail                                                                       Fax                                                                 

Address Line 1                                                                                                                             

Address Line 2                                                                                                                             

City                                                                            State                      Zip                                    

Comments:

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание 80-6001

Страница 1: ...ump electrical parts one 1 year Parts replaced or repaired under this warranty are warranted for the remainder of the original warranty period Service labor charges are covered for one 1 year from the date of purchase when performed by a manufacturer authorized service provider Labor is only provided by authorized service centers If an authorized service center is not near you it is the purchaser ...

Страница 2: ... or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 15571 Container Lane Huntington Beach CA 92649 Visit our website at www sandiaplastics com Register your machine online at www sandiaplastics com registration aspx Mail to Ultimate Solutions Corporate Offices 15571 Container Lane Huntington Beach CA 92649 See reverse side for Warranty Infor...

Страница 3: ...urer must issue an RMA Sheet containing approved labor time and replacement parts Do not send parts or equipment back to manufacturer without an RMA number and approval No labor will be paid for nor part costs paid for or reimbursed that have not been previously approved by the manufacturer All warranty work must be approved and authorized to qualify and appropriate warranty procedures must be fol...

Страница 4: ...r reimbursement TheoriginalpurchasermustcontactthemanufacturertofollowcorrectRMA warrantyprocedures They must include a copy of the RMA Sheet enclosed in the box with the returned item No returns shall be authorized unless the proper RMA procedures are followed It is the responsibility of the distributor to repair the client s equipment as soon as possible The manufacturer charges a 25 restocking ...

Страница 5: ...lood pumper before connecting disconnecting or working on the machine This equipment must be connected to a properly grounded outlet only see grounding instructions The extension cord provided with this unit is 1 25 foot 12 3 gauge safet power cord and MUST be used with this unit to ensure grounding protection Turn off all controls before unplugging Make sure the on off switch is in the off positi...

Страница 6: ...ug is necessary DO NOT connect the grounded wire to a flat bed terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire NOTE In Canada the use of a temporary adapter is not permitted by the Canadian Electrical Code 8 0 Trouble Shooting Guide CAUTION Always disconnect the power cord before servicing equipment WARNING Never operate ...

Страница 7: ... of the machine s base Push the end of the auto dump hose onto the QD dump port Close the latches on each side of the hose so that it is securly locked to the dump port Note only one side of this hose will properly fit onto the dump port Do not force Place the other end of the hose in a commode or drain connected to a sanitary sewer system 4 2 Connect the Vac Hose The vacuum hose is a 25 foot 1 1 ...

Страница 8: ...al injury or death Regular maintenance is required to keep your flood pumper in proper working condition Failure to properly maintain your machine could VOID warranty Thoroughly clean all equipment and accessories after each use Operation Interval Clean Vacuum Float Assembly Screen Daily After Each Job Clean Auto Dump Pump Out Recovery Tank Daily Clean Dump Valve Daily 6 1 Clean Vacuum Float Assem...