Installation

Wall mount

There are two fastening clips on the reverse 
side of the ozonizer. These may be used 
for wall mount. It is recommended that the 
ozonizer be mounted above the water level. 
This will prevent water from flowing back into 
the ozonizer, eg. in the event of a power failure.

Cabinet installation

The ozonizer may be installed in an equipment 
cabinet. If the ozonizer is operated in a 
small enclosed space such as a cabinet, it is 
essential to provide sufficient ventilation to 
avoid overheating. If the ozonizer is installed 
below the water level, provide a loop of tubing 
extending above the water level to avoid water 
flowing back into the ozonizer.

Connecting the ozonizer for skimmer 
operation with airstones

Connect the air inlet 

(9)

 to an air pump using 

6/8 mm tubing. Connect the ozone outlet 

(6)

 

to the airstone in the skimmer using ozone-
resistant tubing. 

If ozone production is turned off while the 
ozonizer is still connected to the skimmer, the 
air supply must remain on. This will prevent 
water from entering the ozone generator.

Connecting the ozonizer for skimmer 
operation with an injector

Connect the injector with the ozone outlet 

(6)

In this setup, airflow through the ozonizer is 
provided automatically. To keep the inlet air 
free of contaminants (including dust), it is 
recommended to use a filter at the air inlet 

(9)

.

Setup

1

  Mount the ozonizer and power supply in a 

dry environment.

2

  Connect the tubing for inlet air and ozone.

3

  Connect the power suppy: first, insert the 

24 volts plug from the power supply into the 
socket 

(7)

 on the ozonizer, then connect the 

power cable with the power supply. Finally, 
insert the wall plug on the power cable into 
the mains socket.

Ozone

Air

Ozone

Tubing loop

Air

Содержание XT2000

Страница 1: ...Ozonizer XT2000 User Guide EN...

Страница 2: ...y cause damage creating a faulty voltage potential inside the ozonizer In this event please disconnect the ozonizer from the power supply immediately removing the wall plug from the mains socket Blowi...

Страница 3: ...nnector 7 Disconnect the tubing for inlet air and ozone Remove the screws 4 holding the ozone generator cover 5 in place using the supplied hex tip tool Remove the ozone generator cover 5 Wipe the ozo...

Страница 4: ...nsist of two parts a thick center bar with two thin bars above and below The thin bars indicate the set value while the thick bar indicates the actual current measured value Using a redox controller W...

Страница 5: ...in combination with a redox controller Sander redox potential detector and controller part number 7 1C This device automatically turns the ozonizer on or off depending on a set value for the redox po...

Страница 6: ...rews for the ozone generator cover 5 Ozone generator cover 6 Ozone outlet connector for 6 8 mm tubing 7 3 pin connector for power supply 24 volts 8 4 pin connector for Sander Redox Controller with dum...

Страница 7: ...x Controller Hex tip Allen tool Mounting hooks 2 Mounting dowels 2 User guide Intended use for aquariums and ponds The ozonizer is a device for generating ozone from air It was developed speci cally f...

Страница 8: ...nce and cleansing tasks may be performed by children only under supervision Do not open the ozonizer s casing Improper repair work or other modi cations may create considerable hazards In the event th...

Страница 9: ...9 to an air pump using 6 8 mm tubing Connect the ozone outlet 6 to the airstone in the skimmer using ozone resistant tubing If ozone production is turned off while the ozonizer is still connected to t...

Страница 10: ...e Eltze Germany Phone 49 51 73 9 71 0 Fax 49 51 73 9 71 197 E mail info aqua sander de Web www aqua sander de 2 2018 Erwin Sander Elektroapparatebau GmbH Design ngin de For more information expert adv...

Отзывы: