Sanden GS3-45HPA-US Скачать руководство пользователя страница 2

Sanden

 

Heat

 

Pump

 

 

Installation

 

Manual

 

Page

 

2

 

of

 

36

 

 

Contents 

 

Page title .............................................................................................................................. 1

 

Contents .............................................................................................................................. 2

 

Introduction .......................................................................................................................... 3

 

How it works ........................................................................................................................ 3

 

Installation details ................................................................................................................ 4

 

Installation location .............................................................................................................. 5

 

Heat pump Unit Installation .................................................................................................. 6

 

Water Piping Installation – Heat Pump Unit & Tank ............................................................. 7

 

Heat Pump Unit Water piping .............................................................................................. 9

 

Mains Power/Electrical Installation .................................................................................... 10

 

Electrical connections ........................................................................................................ 10

 

How to connect Main Power .............................................................................................. 10

 

How to connect Tank thermistor cable to Heat Pump unit ................................................. 12

 

System operation using continuous Power Supply ............................................................ 13

 

System operation if connected to Demand Response Power ............................................ 13

 

Filling the System & Purging Air ........................................................................................ 15

 

Freeze protection ............................................................................................................... 16

 

Time setting ....................................................................................................................... 17 
Controller Operation .......................................................................................................... 19

 

Commissioning Mode ........................................................................................................ 19

 

How to switch to Commissioning Mode ............................................................................. 19

 

Error Codes ....................................................................................................................... 24

 

Water Supply Quality (Supplemental) ................................................................................ 26

 

Change of water supply ..................................................................................................... 27

 

Technical data ................................................................................................................... 28

 

Warranty Policy .................................................................................................................. 32

 

Warranty period ................................................................................................................. 33

 

Check sheet ....................................................................................................................... 34

 

Replace controller assembly .............................................................................................. 35

 

Memo ................................................................................................................................. 36

 

 

 

 

 

 
 
 
 

 
 

 

 

 

 

 

 

PATENTS 

This water heater may be protected by one or more patents or registered designs 

in the name of Sanden International (USA), Inc. 

TRADE MARKS 

® Registered trademark of Sanden International (USA), Inc. 

 

Note:

 

Every care has been taken to ensure accuracy in preparation of this publication. 

No liability can be accepted for any consequences that may arise as a result of its application.

Содержание GS3-45HPA-US

Страница 1: ...l numbers for residence Heat Pump Unit GS3 45HPA US This appliance is not to be installed by unqualified and unlicensed persons please read and understand this manual prior to installing and operating...

Страница 2: ...13 Filling the System Purging Air 15 Freeze protection 16 Time setting 17 Controller Operation 19 Commissioning Mode 19 How to switch to Commissioning Mode 19 Error Codes 24 Water Supply Quality Suppl...

Страница 3: ...e most energy efficient units currently available It is even more efficient when connected to demand response power and the noise level is so low it will operate unobtrusively at any time How it works...

Страница 4: ...table and non potable water and consultation with Sanden The unit is designed to operate when connected to the water supply with a maximum operating pressure of 95PSI 655 kPa To ensure the mains press...

Страница 5: ...d installing it directly below a bedroom window Install the heat pump unit in an area which allows sufficient ventilation Poor ventilation may cause the unit to short cycle and this could increase pow...

Страница 6: ...or pre fabricated pump ups to raise the Heat Pump unit 4 6 from the ground this will allow defrost condensate to drain In areas with significant snowfall ensure unit is mounted above the anticipated...

Страница 7: ...nstallation kit for the heat pump unit Attach a drain hose with 5 8 inch 16mm of inner diameter to the drain elbow to guide the drained water to an appropriate drain Water Piping Installation Heat Pum...

Страница 8: ...erial with a mild detergent before doing any piping work and smooth the edges to remove any scratches and burrs After flowing water through it verify whether any debris has accumulated on the filter o...

Страница 9: ...e tank unit marked Hot Water Outlet Install the PR valve to the fitting on the tank unit marked PR valve pipe from PR valve directly to a Building drain do not install any shut off valve between PR va...

Страница 10: ...this system must be carried out only by a qualified installation technician electrical HVAC or plumbing Electrical connections Breaker size and wiring must be sized per NEC rules for the rating plate...

Страница 11: ...Sanden Heat Pump Installation Manual Page 11 of 36 Figure 7 Main Power Connection...

Страница 12: ...ny further Pull the conduit several times to ensure the connector is fixed properly to the conduit Unscrew and carefully remove the terminal block cover on the tank Do not use unnecessary force to rem...

Страница 13: ...than 40 gallons 150 litres The system will not run if the electrical power supply is cut off However the system will automatically start operation once the electric power supply is restored System op...

Страница 14: ...also affect the duration of the heating cycle operation Figure 9 Outline of electrical system connections The basic system installation is now complete the unit is now ready for initial water filling...

Страница 15: ...to the system Push up the lever on the PR valve to open and fill the tank unit with water Confirm that water comes out of the relief valve and then close the lever Open the hot water faucets to remov...

Страница 16: ...stalling freeze protection Wrap the freeze protection heater around the pipes up to the water connectors of the Heat Pump unit Ensure the freeze protection heaters are connected to a 24 hours continuo...

Страница 17: ...s switched 2 Setting the Clock The time setting can be adjusted by pressing Up and Down keys Fast forward and rewind are available by pressing and holding down either the Up or Down key 3 Confirming T...

Страница 18: ...at Pump Installation Manual Page 18 of 36 Figure 12 How to operate the controller How to remove the operation panel 1 Remove Top Panel 4 screws 2 Pull up Operation Panel Pull up Operation Panel Operat...

Страница 19: ...let Hot water temperature 130 175 F Block out time setting mode Time of use Set the block out time Error history display mode Check the history of any errors that may have occurred Parameter display m...

Страница 20: ...ess Temperature Setting then Press Enter to access Use UP DOWN arrow keys to toggle between the various Temperature Settings Press Enter to confirm choice Settings available 130 140 150 160 165 175 F...

Страница 21: ...ing The end time display NOW starts flashing THIS TIME WILL THE TIME WHEN THE HEAT PUMP IS FIRST PREVENTED FROM OPERATING EVEN IF THE TANK IS COLD Adjust block out end time Set to the desired end time...

Страница 22: ...To bypass the Error History simply press the UP key to access the next parameter in the Commissioning menu Parameter Display Enter into Commissioning Mode First option is the Heat Setting Second optio...

Страница 23: ...mp No 06 Factory Default Value No 07 Ambient temp No 08 Factory Default Value No 09 Factory Default Value No 10 Factory Default Value To bypass the Parameter Display simply press the UP key to return...

Страница 24: ...s are not frozen Ensure mains water supply is available Ensure all shut off valves are open If the water circulation pump is not working replace the pump In areas with hard water ensure Gas Cooler is...

Страница 25: ...015 HP ambient temperature thermistor wire break E016 Tank thermistor wire break E021 HP inlet temperature thermistor wire short circuit E022 HP outlet temperature thermistor wire short circuit E023 H...

Страница 26: ...e water that water can cause corrosion and subsequent failures Where the chloride level exceeds 0 1 ounces per gallons 200 mg litre the warranty is no longer valid on to the heat pump unit and tank un...

Страница 27: ...water heating circulation and the heat exchanger in the system Where there is a changeover from one water supply to another for example a rainwater tank supply desalinated water supply public recircul...

Страница 28: ...aker Size 15A MCA Amps 13 0A Compressor RLA LRA Amps 7 5 9 8A Fan Motor RLA Watts 0 3A 70W Pump RLA Watts 0 2A 30W Noise Level DbA 37 Weight lbs 106lbs Storage Tank GAUS 160QQTA SAN 43SSAQA 43 Gallons...

Страница 29: ...Sanden Heat Pump Installation Manual Page 29 of 36 GS3 45HPA US Dimensions...

Страница 30: ...Sanden Heat Pump Installation Manual Page 30 of 36 Stainless Steel Tank Dimensions...

Страница 31: ...Sanden Heat Pump Installation Manual Page 31 of 36 Wiring Diagram...

Страница 32: ...fuses 5 The Heat Pump Water Heater System must be sized to supply the hot water demand in accordance with the guidelines in the Sanden Heat Pump Water Heater System literature Warranty Exclusions 1 R...

Страница 33: ...ims for damage to furniture carpets walls foundations or any other consequential loss either directly or indirectly due to leakage from the Heat Pump Water Heater System or due to leakage from fitting...

Страница 34: ...rdance with the installation manual Water Piping Action Completed A dedicated water supply shut off valve is installed The piping for the hot water supply has been properly insulated There is no water...

Страница 35: ...t water Temp Setting Mode Block out Time Setting Mode Heat Setting Mode Error History Display Mode UP UP UP UP UP UP Any Key Enter Enter or No Operation for 60sec min No Operation for 60sec min Hold d...

Страница 36: ...Sanden Heat Pump Installation Manual Page 36 of 36 Memo SANDEN Heat Pump 40980 44772 Installation Manual US...

Отзывы: