Use REED Command for Cover Tamper
FRB feature is for detecting the Tamper violation. When the feature is turned on, if the cover of the bracelet is
opened, the alarm will be triggered immediately and the device will send the DT reports to indicate the strap
violation. The DT state will be shown in the state field of report. The interval of DT report depends on the setting.
There may be a buzzing sound or vibration if the buzzer and vibrator are turned on.
Once the alarm is triggered, it will not stop only if the “alarm off” command is being sent.
Regarding the “alarm off” command, please refer to the step 0 in the quick setting of SMS command.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
Setup Format of short type
:
#<User Name>, <Password>, <Function Mode reed>, <0/1 (On/OFF)>*
Example
:
#username,0000,reed,0*
Setup Format of long type
:
#<User Name>, <Password>, <Function Mode reed>, <0/1 (On/OFF)>, <Interval
15~65000>*
Example
:
#username,0000,reed,1,60*
SMS Text
Description
#
Start sign.
username
Default ID of BRACELET.
If you have changed the Username, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
reed
Function code for reed
0/1
Toggle the function:
0 means the device will not detect the strap violation
1 means the feature is enabled. (default)
60
This parameter is for setting up the interval of DT report. The value range is from
15 to 65000. “60” means 60 seconds. (default)
E.g. Once the reed alarm is triggered , the device will send reports every 60
seconds until the “alarm off” command has been received.
*
End sign.
Table: REED Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] +, setup OK. Device reed detection is switched on/off.
Table: REED Setup Response Description