background image

 

 

11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)   

Tel: 886-2-22694456

Fax: 886-2-22694451

[email protected]     

32 

www.etek.com.tw 

©

 U

n

ic

tr

on

 T

ec

h

n

olo

gie
s C

or

p

 A

ll 

spe
cif

ic

at

io

n

su

bje
ct 

to

 c

h

an
g

w

ith

ou

t n

oti

ce

www.sanav.com 

www.unictron.com 

Note: 

(1) Any event marks with letter “

B

” (Bauto…..) represents data which was not able to send to assigned route 

immediately        due to priority or mobile network service is not available. The data will be sent after the issues 

are cleared. 

(2) The event marks with letter

L

(LAUTO) represents power saving mode for data transmission. 

"LAUTO" represents a specific number of AUTO reports. The equipment will send reports at once as a group 

when it has logged a fixed number of reports in the memory. 

 

SMS Command Introduction 

 

SMS Command setting

 

 

10.

 

Any setup command must be started with a “#” sign and ended up with a “*” sign. Please note that all the 

characters which include “#”, “*” and comma (,) should be HALFWIDTH form. 

11.

 

Please be aware of the upper (capital)/lower cases when entering the SMS command. 

12.

 

While entering any SMS command, note that NO SPACE is allowed between the characters, comma and 

signs in the 

SMS. 

13.

 

The comma (,) can be abbreviated if no further setup required for the command besides Set up APN for 

GPRS Service. Please refer to the examples of Set up Auto Report. 

14.

 

The device will update setting only when the password, username and setup command are all correct. 

If the command is not valid, a failure report is going to be sent to the user’s cell phone.   

15.

 

If the device set up the authorized number, SMS commands should be sent via authorized number. 

16.

 

If the command is valid, a success report is going to be sent to the user’s cell phone.

 

17.

 

Please make sure that the Call-Forward function of SIM card is turned off and Call-Display function of SIM 

card is turned on.

 

18.

 

Please make sure that the PIN-Code of SIM card if off. If the PIN-Code is necessary, use 0000 as PIN-Code.

 

 

 

 

 

 

 

 

 

 

Содержание NB-5

Страница 1: ...0 San Jose Technology Inc All Rights Reserved This document contains information that is the property of SANAV This document may not be copied reproduced reduced to any electronic medium or machine re...

Страница 2: ...P 6 Set up APN for 3G Service 23 STEP 7 Set up URL and TCP UDP IP Address 24 STEP 8 Set up Route for Data Transmission 26 STEP 9 Set up Auto Report Optional 27 Step 10 Request IMEI Number 28 Appendix...

Страница 3: ...m Cold Cold Warm 26 seconds Hot 1 second Position Accuracy 2 5 meter CEP 50 24 hours static 130dBm SEP 3 5m RF RF Module RIFO TI CC1101 Modulation FSK Frequency 436 8MHz Sensitivity 116dBm 0 6kbaud Sy...

Страница 4: ...ntaining latitude longitude date and time to assigned monitoring center It is specially designed for the intensive tracking applications such as offender tracking or life security Note In the house pl...

Страница 5: ...light will stay on 2 GSM LED Red While the device gets GSM fixed or in normal operation the GSM light will flash every 3 seconds In case of weak GPS signal the GSM LED will flash every second When GSM...

Страница 6: ...hnologies Corp All specifications subject to change without notice www sanav com www unictron com charged the CH LED will stay on Unplug the charger when the device is fully charged In this situation...

Страница 7: ...Dist New Taipei City 236 Taiwan R O C Tel 886 2 22694456 Fax 886 2 22694451 service unictron com 7 Unictron Technologies Corp All specifications subject to change without notice www sanav com www unic...

Страница 8: ...cm from an outer ankle 2 Circle the user s leg with strap and determine the length of the strap that leaves approximately 20 30 mm 2 3 scales of space between the use s leg and the strap for comfortab...

Страница 9: ...and wearing purpose 6 While cutting the strap by using the dedicated strap it should proceed with 3 stages cutting procedures Keep cutter and strap at 90 degree angle to make sure that the cutting ed...

Страница 10: ...hout notice www sanav com www unictron com 7 Cut procedures are completed 8 Put up the Jelly cover at the end of strap Please refer to NB5 Jelly cover assembly SOP 9 Fix the strap clip at the end of s...

Страница 11: ...orp All specifications subject to change without notice www sanav com www unictron com 11 Activated Start tracking 12 While using wall charger aim the charger connector female to NB5 charge socket mal...

Страница 12: ...tron Technologies Corp All specifications subject to change without notice www sanav com www unictron com Cutting Tools 1 Make sure that the front side of the cutting tool faces to you and that the st...

Страница 13: ...ject to change without notice www sanav com www unictron com 3 After making sure the location is right push the top of cutting tool to cut the strap 4 Exchange the blade if needed Release the screw an...

Страница 14: ...n com 14 Unictron Technologies Corp All specifications subject to change without notice www sanav com www unictron com 5 Install the blade Please make sure the edge of the blade is inside the white ar...

Страница 15: ...pdate setting only when the password username and setup command are all correct If the command is not valid a failure report is going to be sent to the user s cell phone 6 If the device set up the aut...

Страница 16: ...0 19 1 1 0 means to disable it The 1st parameter is for toggling the buzz alarm function The 2nd is for toggling the vibration alarm function 2 Once the events are triggered deactivate all alarm by se...

Страница 17: ...username to a new user name abc Only enter new command with new user name after it has been changed Setup format username Password Function Code New username Example username 0000 1 abc SMS Text Desc...

Страница 18: ...password 1111 Only enter command with new password will be valid for setting change after it has been changed Setup format username Password Function Code new Password new Password Example username 0...

Страница 19: ...or something The maximum set of Security Phone Number is 3 We can simply set up one number or two numbers as well Setup format User Name Password Function Mode Security Number1 Security Number2 Securi...

Страница 20: ...3 00 A 2457 80794 N 12125 53854 E 0 012 170720 A 67 AUTO I0200 9999 M14 4182mV 33 1 48 466 1 24A5 13E16E9 30 FFFF 29 10613 26 19 FFFF 195 10613 26 19 NB5 s HA ID is for the purpose that user can quick...

Страница 21: ...types of command the short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode rf433 0 1 Detectio...

Страница 22: ...umber of set of equipments in the same place such as more than 10 sets we can set them in groups and configure each set to different channel and it will reduce the possibility of disturbing each other...

Страница 23: ...re not required just leave the parameters empty no space User can follow the Setup Format below to setup the APN that is provided by your GSM carrier Setup Format username Password Function Mode APN n...

Страница 24: ...nction code 4 to setup the URL as the following command to configure URL for HTTP Setup Format User Name Password Function Mode 4 URL Example username 0000 4 http www sanavtw com uploadM1 php SMS Text...

Страница 25: ...tup Format User Name Password Function Mode TCP IP Address Port Example username 0000 18 202 39 31 127 13337 SMS Text Description Start sign username Default ID of Bracelet If you have changed the Use...

Страница 26: ...PS data by SMS message format to Cellular phone that has been set in Phone Book User can choose the route to transmit the data by HTTP TCP SMS protocol individually or with SMS message as a backup rou...

Страница 27: ...he following example it will send a report every 1 minute 60 seconds and the total number of reports is 10 Setup Format User Name Password Function Mode intervals sec Number of Reports Example usernam...

Страница 28: ...ion a unique number for identifying mobile devices validity in GSM network As above stated each device has a unique IMEI number Entering the SMS command as the following allows user to check the IMEI...

Страница 29: ...a unique number for identifying mobile devices validity in GSM network 2 Main GPRMC Sentence 1 081219 00 time of fix UTC 2 A GPS fix status A GPS fix V GPS no fix 3 2457 80821 N 12125 53897 E Latitud...

Страница 30: ...ts 17 RSCP Level Received Signal Code Power expressed in dBm levels 0 less than 115 dBm 1 90 from 115 dBm to 26 dBm with 1 dBm steps 91 25 dBm 18 Reserved FFFF 19 scrambling_code Scrambling code The r...

Страница 31: ...is greater than AUTO the AUTO report will suspend The AUTO report recovers until the Alarm OFF command has been sent and the Alarm status ends POLL When the device has received the POLL command the P...

Страница 32: ...note that all the characters which include and comma should be HALFWIDTH form 11 Please be aware of the upper capital lower cases when entering the SMS command 12 While entering any SMS command note t...

Страница 33: ...immediately and then you can use this command Please make sure that those reports in flash won t be needed anymore before you use it Setup Format User Name Password Function Mode er Example username 0...

Страница 34: ...sername 0000 rst now Table Restart Format Description Table Restart Response Description SMS Text Description Start sign username Default user name of the device If you have changed the username pleas...

Страница 35: ...0000 rst cfg 6 Table Restart Setting Format Description Table Setting Restart Response Description SMS Text Description Start sign username Default user name of the device If you have changed the use...

Страница 36: ...command the POLL message will be sent to the server depending on the route you ve set The POLL message will be shown in the Event field of the report Setup Format User Name Password Function Mode 10...

Страница 37: ...here are two types of command the short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode fbr 0...

Страница 38: ...short one is for toggling the function quickly and the long one is for setting up all the parameter Setup Format of short type User Name Password Function Mode reed 0 1 On OFF Example username 0000 re...

Страница 39: ...n OFF 1 Interval of beep sound 180 Interval of vibration Example username 0000 19 1 1 1 180 SMS Text Description Start sign username Default ID of BRACELET If you have changed the Username please use...

Страница 40: ...tion Message Reply Buzzer setup succeed username setup OK Device buzzer is turned off on Vibrator setup succeed username vibration motor is disabled enabled Buzzer and Vibrator setup scceed username s...

Страница 41: ...er Saving Mode to 1 to disable it such like this command username 0000 combo 1 Setup Format User Name Password Function Mode Power Saving Mode Command username 0000 combo 3 Table Power Save Mode Setup...

Страница 42: ...ername 0000 aes 1 Table AES128 encryption Setup Format Description Situation Description Success username setup OK Device data for aes128 protection is switched off on fail username command error Tabl...

Страница 43: ...Mode Command username 0000 tcpack 1 Table TCP acknowledge Setup Format Description Situation Description Success username setup OK Device tcp ack mode is updated fail username command error Table TCP...

Страница 44: ...le Low Power Setup Description Table Low Power Setup Response Description SMS COTA Command Description Start sign UserName Default ID of the device If you have changed the user name please use the upd...

Страница 45: ...cellid 1 SMS COTA Command Description Start sign UserName Default ID of the device If you have changed the user name please use the updated one 0000 Default password If you have changed the password...

Страница 46: ...anged the user name please use the updated one 0000 Default password If you have changed the password please use the updated one Function Code Code fota defines the firmware upgrade function URL of fi...

Страница 47: ...e the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio...

Отзывы: