- 30 -
FP120D,FP145D
5.1. Electrical scheme
Main
disconnector
(switch type)
with
undervoltage
release trip
Moeller
P1-32EASVB 250Vac, 30A
EN60947-1
EN60947-2
Motor breaker
Moeller
PKZM0-32
Telemecanique GV2
250Vac, 30A
EN60947-1
EN60947-2
5. Technical Manual
Electrical components list
FP120D, FP145D
ltem
Q1
F1
F2
KM1
TC1
M1
SB1
U1
SB2+
HL1
SB3
Description
Manufacture
Type
Technical data
Standards
Marking
CE Instruction Manual
Circuit breaker
Moeller
FAZ-2-S1
Telemecanique C60N C1A
240/415V~
1Ax1P
EN60947-2
Magnetic
contactor
Telemecanique LC1D
TECO
CN-18
Ui=660V
1th=32A
EN60947-2
EN60947-4-1
Transformer
control circuit
supply
San Li
SL-9640
Suenn Liang
SP-TBSW
0.082kVA
1~, 380V/18V,
24V
IEC61558-1
lEC61558-2-4
Pump motor
TATUNG
BEFC-D
5.6kW (7.5HP)
3~, 380V,50Hz,
14.5A, IP54, S1
INS. B
EN60034-1
Moeller
DILM 32D
Emergency
Stop
Moeller
RMQ
(M22-k01)
Ui=500V
1th=4A,Uimp=6kV
EN60947-5-1
Push button
(ON)
with indicator
Moeller
RMQ
(M22-k10+
M22-LED230)
Ui=500V
1th=4A,Uimp=6kV
EN/IEC60947
Push button
(OFF)
Moeller
RMQ
(M22-k01+
M22-LED230)
Ui=500V
1th=4A,Uimp=6kV
EN/IEC60947
Power PCB+
Control PCB
24Vac, 18Vac,
15Vac, 10Vac
-
-
www.samway.com