The  supply  voltage  should  be  within  the  specified 

voltage range.

*

Water temperature for operation of the pump should not 

exceed 33°C.

*

Failure to observe precautions given above could cause 

pump to malfunction and may lead to current leakage or 
electrical shock.

*

If you find any abnormalities like vibration, noise, smell, 

etc., from the pump during trial operation, switch OFF the 
pump and contact the dealer from whom this pump was 
purchased.

CAUTION

6

OPERATION PRECAUTIONS

8. INSTALLATION PROCEDURE

Please follow the below procedure to install the OWS.

*

Switch OFF power before working on electrical lines.

*

Do  not  use  this  pump  for  pumping  liquid  exceeding 

33°C as this may lead to product failure.

*

Do not switch ON pump if there is any human contact 

with pumped medium. If any electrical leakage occurs, 
this could prove fatal.

*

The  OWS  has  water  lubricated  journal  and  thrust 

bearings and therefore must not be run dry. Starting of 
OWS without water must be strictly avoided as it will 
cause damage to the bearings. Fill with pure drinking 
water.

*

During  monsoons,  the  pump  will  run  with  higher 

flooded  suction  resulting  in  the  pump  running  with 
higher discharge. This results in increase in the current 
drawn being higher than that specified on the name 
plate. Fit a gate valve in the delivery line to throttle the 
discharge till the current is lower than that specified on 
the name plate.

*

Ensure  proper  direction  of  rotation  of  the  pump  on 

powering up.

CAUTION

INSTALLATION

The following steps are to be executed prior to installation

l

Open the filling plugs and top up if necessary, with pure drinking water.

l

Measure Insulation Resistance using a Megger of 500 VDC.

l

Ensure contact points are clean.

l

Check direction of rotation.

l

Connect measuring cable to ground conductor.

l

Connect  the  other  measuring  cable  to  every  core  of  the  motor  cable  in 

succession.

l

Ensure  that  insulation  resistance  as  shown  on  the  Megger  is  a  minimum  of 

20MÙ.

l

Use prescribed pipe sizes as mentioned on the product name plate.

l

Refer  Fig.2,  shown  below  for  locating  the  OWS  for  operation  with  flooded 

suction.

Fig.2 OWS With Flooded Suction

7

Содержание SSM-N Series

Страница 1: ......

Страница 2: ...ontents in the Packing Box 1 4 Introduction about Product and Briefing 1 5 Schematic Drawings Indication of Parts 2 6 Key Product Specifications and Features 3 7 Pre Installation Requirements 4 8 Inst...

Страница 3: ...et submerged resulting in the motor getting damaged To overcome the issue of varying static suction lifts Open Well Submersible Monobloc OWS has been introduced Such a pump operates submerged Samudra...

Страница 4: ...NG SAND GUARD OIL SEAL FRONT COVER BASE PLATE BUSH THRUST PAD BALANCING COLLAR HEX HEADED BOLT WASHER EARTH INDICATION PLATE ROTOR WITH SHAFT STATOR STACK HEX HEADED BOLT HEX SOCKET SET SCREW COUNTER...

Страница 5: ...e thrust load generated by rotating impeller l A water lubricated counter thrust bearing is provided to limit movement of the shaft when the OWS is switched OFF l The rotors are dynamically balanced l...

Страница 6: ...ation l Ensure that the bottom of the well water source is fairly level before erection of the OWS GENERAL INSTALLATION PRECAUTIONS l Open packaging and note down Serial number and Model for future re...

Страница 7: ...oil or toxic acetic corrosive and flammable liquids Pumping flammable liquids could cause explosion Use eye bolts for lifting lowering the OWS Ensure suitable precautions are taken while lifting and...

Страница 8: ...pumping liquid exceeding 33 C as this may lead to product failure Do not switch ON pump if there is any human contact with pumped medium If any electrical leakage occurs this could prove fatal The OW...

Страница 9: ...are clean l Check direction of rotation l Connect measuring cable to ground conductor l Connect the other measuring cable to every core of the motor cable in succession l Ensure that insulation resist...

Страница 10: ...the Motor of OWS With Pure Drinking Water The Brass Plug 3 mounted on the bottom of the motor is used for draining the water from within the motor Ensure all three Brass Plugs are tightened to prevent...

Страница 11: ...rproof Refer to sequence shown in Fig 4 below for insulating the cable joint for under water application PROCEDURE FOR JOINING AND INSULATING THE 3 CORE CONDUCTORS PROCEDURE FOR INSULATING THE CABLE J...

Страница 12: ...onnect the OWS to Control Panel power up the OWS and observe the discharge from the pump l Next interchange any two phase wires power up the OWS and observe the discharge from the pump l In case the d...

Страница 13: ...ration while selecting cable size ELECTRICAL WIRING WORK CAUTION Be sure to install the ground wire securely Failure to observe this precaution could damage the pump and cause current leakage which ma...

Страница 14: ...proper packing in which they should remain until they are ready to be installed l The product should be stored in a closed dry and well ventilated room l Do not store the product under direct sunligh...

Страница 15: ...0 The Working Capitol Singapore 089109 Tel 65 6813 2111 Email info samudra net India Operations Office Block 1 Ground Floor Senthil Towers 1078 Avinashi Road Coimbatore 641 018 Tamilnadu India Tel 91...

Отзывы: