PUMP

l

content of 50 grams in 1000 ml of water. For higher sand content, the pump 
hydraulics will wear out at a faster rate.

l

The impeller is dynamically balanced.

l

Both suction and delivery flanges with rubber gaskets are assembled on the 
volute casing.

l

Strainer  assembly,  fitted  on  the  pump  suction  flange,  prevents  entrance  of 
large-sized debris into the pump.

ELECTRICAL CONNECTION

l

OWS to be connected to a DOL starter are provided with a single 3-core PVC flat 
cable. 

l

OWS to be connected to a Star-Delta starter are provided with two separate 3-
core PVC flat cables.

7. PRE-INSTALLATION REQUIREMENTS

ARRANGEMENT FOR INSTALLATION

l

Use services of a professional and trained mechanic with experience in erecting 
OWS.

l

Ensure proper safety during installation.

l

Ensure that the bottom of the well/water source is fairly level before erection of 
the OWS.

GENERAL INSTALLATION PRECAUTIONS

l

Open packaging and note down Serial number and Model for future reference.

l

Ensure all fasteners are tightened properly.

l

Use prescribed pipe sizes as mentioned on the product name plate.

l

To  prevent  motor  from  getting  exposed  during  pumping,  ensure  suction 
strainer is fitted above the level of the motor. This is done by fitting one end of 
the bend to the pump suction flange and the strainer to the other end of the 
bend, thereby ensuring that the level does not fall below the strainer.

l

Use an NRV fitted on the delivery line when the OWS has high static delivery 
heads.

l

Use  a  power  cable  without  joints  from  OWS  to  Control  Panel.  It  is  not 
recommended to use a power cable with large number of joints as this can result 
in a significant voltage drop.

The  pump  is  designed  for  pumping  clear,  cold  water  with  a  maximum  sand 

5

l

l

Check availability of three-phase power.

l

Ensure availability of Control Panel with inbuilt single-phase preventer, overload 
protection, and High-Voltage and Low-Voltage protection.

l

Fill motor with pure drinking water before installation.

l

In case of rapid rise of water levels during rainy season, provide a throttle valve in 
the delivery pipeline.

l

While installing the OWS, ensure that it is not subject to shock loads which can 
damage OWS parts.

Check for level of silt at the bottom of well. De-silt if necessary.

*

If  you  detect  damage  or  discrepancy  in  the  product, 

contact the dealer from whom the pump was purchased.

*

Do not use this pump for oil or toxic, acetic, corrosive and 

flammable  liquids.  Pumping  flammable  liquids  could 
cause explosion.

*

Use  eye  bolts  for  lifting  /  lowering  the  OWS.  Ensure 

suitable precautions are taken while lifting and lowering 
the product.

*

Use trained professionals to install the OWS

*

Use a power supply cable that has sufficient rating. Factor 

in low-voltage operation.

*

Provide  proper  Earthing.  Improper  Earthing  can  cause 

electrical shock

*

Use a Megger to verify insulation of the motor. Insulation 

resistance should be 20 MÙ minimum.

*

Do  not  run  OWS  dry  as  it  contains  water  lubricated 

bearings and oilseals.

*

Mount the pump with its axis horizontal.

*

It is recommended to use a starter.

*

Check  the  bottom  of  the  well.  In  case  there  is  mud 

accumulated at the bottom, de-silt the well.

*

Periodically  de-silt  the  bottom  of  the  well  so  that  the 

OWS rests on the rocky bottom.

CAUTION

Содержание SSM-N Series

Страница 1: ......

Страница 2: ...ontents in the Packing Box 1 4 Introduction about Product and Briefing 1 5 Schematic Drawings Indication of Parts 2 6 Key Product Specifications and Features 3 7 Pre Installation Requirements 4 8 Inst...

Страница 3: ...et submerged resulting in the motor getting damaged To overcome the issue of varying static suction lifts Open Well Submersible Monobloc OWS has been introduced Such a pump operates submerged Samudra...

Страница 4: ...NG SAND GUARD OIL SEAL FRONT COVER BASE PLATE BUSH THRUST PAD BALANCING COLLAR HEX HEADED BOLT WASHER EARTH INDICATION PLATE ROTOR WITH SHAFT STATOR STACK HEX HEADED BOLT HEX SOCKET SET SCREW COUNTER...

Страница 5: ...e thrust load generated by rotating impeller l A water lubricated counter thrust bearing is provided to limit movement of the shaft when the OWS is switched OFF l The rotors are dynamically balanced l...

Страница 6: ...ation l Ensure that the bottom of the well water source is fairly level before erection of the OWS GENERAL INSTALLATION PRECAUTIONS l Open packaging and note down Serial number and Model for future re...

Страница 7: ...oil or toxic acetic corrosive and flammable liquids Pumping flammable liquids could cause explosion Use eye bolts for lifting lowering the OWS Ensure suitable precautions are taken while lifting and...

Страница 8: ...pumping liquid exceeding 33 C as this may lead to product failure Do not switch ON pump if there is any human contact with pumped medium If any electrical leakage occurs this could prove fatal The OW...

Страница 9: ...are clean l Check direction of rotation l Connect measuring cable to ground conductor l Connect the other measuring cable to every core of the motor cable in succession l Ensure that insulation resist...

Страница 10: ...the Motor of OWS With Pure Drinking Water The Brass Plug 3 mounted on the bottom of the motor is used for draining the water from within the motor Ensure all three Brass Plugs are tightened to prevent...

Страница 11: ...rproof Refer to sequence shown in Fig 4 below for insulating the cable joint for under water application PROCEDURE FOR JOINING AND INSULATING THE 3 CORE CONDUCTORS PROCEDURE FOR INSULATING THE CABLE J...

Страница 12: ...onnect the OWS to Control Panel power up the OWS and observe the discharge from the pump l Next interchange any two phase wires power up the OWS and observe the discharge from the pump l In case the d...

Страница 13: ...ration while selecting cable size ELECTRICAL WIRING WORK CAUTION Be sure to install the ground wire securely Failure to observe this precaution could damage the pump and cause current leakage which ma...

Страница 14: ...proper packing in which they should remain until they are ready to be installed l The product should be stored in a closed dry and well ventilated room l Do not store the product under direct sunligh...

Страница 15: ...0 The Working Capitol Singapore 089109 Tel 65 6813 2111 Email info samudra net India Operations Office Block 1 Ground Floor Senthil Towers 1078 Avinashi Road Coimbatore 641 018 Tamilnadu India Tel 91...

Отзывы: