background image

RY9 Washer Heater Relay

 

1 Heater (Red)

 

2 (N) (Wht)

 

CN9

 

1 Motor Pwr U Phase (Blu)

 

2 Motor Pwr V Phase (Wht)

 

3 Motor Pwr  W Phase (Red)

 

CN10

 

1 Main Valve (Blu)

 

2 Hot Valve (Red)

 

3 Pre Valve (Yel)

 

4 Bleach Valve (Pnk)

 

6 Drain Pump (Blk)

 

7 Door Lock Close (Sky)

 

8 Door Lock Open (Wht)

 

CN8 (Hull Sensor)

 

1  +5 vdc (Pnk)

 

2 Sensor Signal (Red)

 

3 Sensor Signal (Blu)

 

4 Ground (Org)

 

CN7

 

1 to AG pcb (Wht)

 

3 Door Lock & Valve common (to L)(Blk)

 

CN5

 

1 AC Pwr (N) (Wht)

 

3 AC Pwr (L) (Blu)

 

CN3

 

3 Water Temp Thermistor(Wht)

 

4 Door Sw (Brn)

 

6 Water Temp Thermistor Gnd. (Org)

 

7 Water Level Sensor (Vio)

 

8 Water Level Sensor (Pnk)

 

CN1 & CN2

 

PCB Sub (Display)

 

CN4 AG PCB

 

1 (Red)

 

2 (Blu)

 

3 (Wht)

 

4 (Grn)

 

5 (Pnk) Ground

 

Water Temperature Thermistor Check

 

Test 1

 

Test 2

 

Connector CN 3 Pin 3 (White) and CN3 Pin 6 
(Orange)

 

Operating voltage at Room temperature 
-

 

Operating Resistance at Room 
Temperature (Power off) discon-
nect CN3

 

4.2VDC (5VDC May indicate a connector 
issue)

 

50-57k

 

Door Switch Check

 

Test 1

 

Test 2

 

Connector CN3 pins #6(Org) & # 4(Brn)

 

25VDC Door Open, 0VDC Door Closed

 

Operating Resistance with 
power off

 

 

open with door open, short with 
door closed.

 

Water Level Sensor Check

 

Test 1

 

Test 2

 

Voltage: Connector CN 3 pins #6(Org) & # 7(Vio)  
And Connector CN 3 Pins #6(Org) & #8(Pnk)

       

Resistance: Connector CN 3 Pin 8 (Pink) and CN7 
Pin 7 (Violet)

 

Operating voltage at no water in the 
drum-

 

Operating Resistance  (Power 
off)

 

2.5VDC

 

CN3 Pin 8 (Pink) and Pin 7 
(Violet) 22- 24

  

Hall Sensor Check

 

Test 1

 

Test 2

 

Connector CN8 pins #4(Org) & # 2(Red) additionally  
4(Org) & # 3(Blu)

  

Manually spin the drum to see the volt-
age change, Power On

 

N/A

 

0Vdc or 3.75Vdc

 

Motor Check

 

Test 1

 

Test 2

 

Connector CN9 Pin 1  (Blue), Pin 2 (White) and Pin 
3 (Red)

 

Power Off 11.5

 across Pins 1-2, Pins 1

-3, & Pins 2-3

 

N/A

 

A/C Power Check

 

Test 1

 

Test 2

 

Connector CN 5 Pins 1 (White) and 3 (Blue)

 

Power On 120VAC

 

N/A

 

 

3

Содержание WF337AAR/XAA

Страница 1: ...d fault codes then turn Dial to view error codes Push Start Pause while the code is displayed to view the number of cycles since the error occurred Peripheral Main PCB input Tests 1 Extra Wash Then turn the Dial so that the Normal LED is turned on Next press the Start Pause Key The Water Tem perature will be displayed in Fahrenheit 2 Extra Wash Then turn the Dial so that the Whites LED is turned o...

Страница 2: ...WF337 2 ...

Страница 3: ...ng Resistance at Room Temperature Power off discon nect CN3 4 2VDC 5VDC May indicate a connector issue 50 57kΩ Door Switch Check Test 1 Test 2 Connector CN3 pins 6 Org 4 Brn 25VDC Door Open 0VDC Door Closed Operating Resistance with power off open with door open short with door closed Water Level Sensor Check Test 1 Test 2 Voltage Connector CN 3 pins 6 Org 7 Vio And Connector CN 3 Pins 6 Org 8 Pnk...

Страница 4: ...120VAC with the Heater On and 0VAC with the Heater off Power Off heater resistance is 16 6 Ω Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the motor drive con...

Страница 5: ...e If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error has occurred replace the main PBA The E2 error occurs if the main relay connections are i...

Страница 6: ...y the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause reposition the l...

Страница 7: ... non HE detergents or using too much detergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there will be leaks out of the detergent drawer and door Please advise con sumer of proper de tergent usage Valve 1 Valve 2 Valve 3 Valve 4 MAIN C BLEACH PRE WASH MAIN H It is normal for a small amount of water remaining in Detergent Drawer after it comple...