23
11. Natural Drain/Water Leak Error
- If more than 4 times of water supply and safe water level of Heater are sensed for each course, this
error will occur.
- Display : "
LE
- This error will be released by turning off Power S/W.
12. Tacho Error
- If Motor Tacho is abnormal, this error will occur.
- If Tacho signals are inputted less than 2 for 2sec after Motor started, this error will occur.
- Display : "
3E"
- This error will be released by turning off Power S/W.
13. Motor TRIAC Short Error
- If Tacho signals are inputted more than 300 every 1sec in the operational interval less than 90RPM,
this error will occur.
Turn off Power S/W at that time.
- Display
: "bE
"
- This error will be released by turning off Power S/W.
14. Thermistor Abnormal Error
- If Thermistor circuit is abnormal, this error will occur.
- If Thermistor is lower than 0.2V or higher than 4.5V, this error will occur.
- Display
:"tE"
- This error will be released by turning off Power S/W.
Содержание WF-F1256
Страница 6: ...45 R0158 I0043 U0355 U0095 U0010 U0015 U0307 U0033 U0016 U0018 D0048 R0030 U0029 U0038 U0355 U0355...
Страница 16: ...6 2 2 OVERVIEW OF THE WASHING MACHINE...
Страница 19: ...9 3 PRODUCT SPECIFICATIONS 3 1 OVERVIEW OF THE CONTROL PANEL...
Страница 42: ...50 9 SCHEMATIC DIAGRAM 9 1 EMZ F1256 F1056...
Страница 43: ...51 9 2 ROLD F856...
Страница 53: ...51 9 SCHEMATIC DIAGRAM 9 1 EMZ F125AC F105AV...
Страница 54: ...52 9 2 ROLD F85A...
Страница 55: ...51 9 SCHEMATIC DIAGRAM 9 1 EMZ F125AC F105AV...
Страница 56: ...52 9 2 ROLD F85A...