30 _ Troubleshooting
No.
Information Type Information
Code
Causes
Corrective Actions
14
Power
UC
(9C)
- Power condition fault.
- This occurs when under or over voltage is supplied.
- Extension lead or plug adapter is being used.
- Main PBA fault (sometimes)
• Check the power supply, polarity
and voltage.
• Select a hot wash or dry cycle
(wd only), measure the voltage
supplied during heating. (A error
occurs when under voltage is
detected.)
* Safety ensure safe working
practices observed when testing
live appliance.
• Check if a socket outlet adaptor is
being used.
• Main PCB fault (sometimes)
15
Mems PBA
8C
- Error detected in the Mems PBA or data error
detected.
• Check the wire connections.
Replace if necessary.
1. Check the wire connections.
2. Replace the Mems PBA.
3. Main PBA wire connection
error or PBA’s silver nano part
malfunction.
Replace if necessary.
16
Add Door
DDC
- A switch contact error because of damage to the Add
Door switch.
- When the add door is pulled by force.
- This occurs in the hot wash because the add door is
pushed due to a pressure difference from internal
temperature changes.
- S/W contact fault because of LID TC “L” transformation.
• Add door open/close switch fault.
• Main PCB fault.
DC3
- The Add Door lock switch terminal is connected
incorrectly.
- The Add Door lock switch terminal is broken.
- This occurs due to Low insualtion of the wiring assy.
- Main PCB fault.
• Add door lock switch fault.
• Main PCB fault.
17
Detergent
Drawer Motor
6C
- Auto detergent dispense motor constrain
- Auto detergent dispense motor wiring
- Auto detergent dispense motor not operate
• Check motor operation by
pressing the laundry when you
enter auto detergent dispenser.
• If not operation change ASSY
PUMP DRAIN.
18
Auto Dispense
6C1
- The input arrest of the detergent motor is sensed.
Check the wire and if necessary
replace it.
1. Check Wire connection
2. Replace Assy Pump
6C2
- The non-operation of the detergent motor is sensed.
6C3
- The in put arrest of the fabric softener motor is sensed.
6C4
- The non-operation of the fabric softener motor is
sensed.
6C5
- The motor motion perception sensor fault
6C6
- The detergent level perception sensor fault
6C7
- The fabric softener level perception sensor fault