Fault Photo
Symptoms and Corrective Actions
Remarks
Symptoms: DVI signals are not recognized.
Causes: This fault occurs when the PC does not
recognize the mode information because
the DVI DDC has not been input to the
monitor.
Corrective Actions: Input the DVI DDC to the monitor.
* Refer to the Training Manual for
information on inputting the DVI DDC.
Symptoms: When the monitor is turned on,
only a full white pattern is displayed
continually regardless of the signals.
Causes: This fault occurs when only the lamp
power is supplied and no video signals are
input to the panel due to a fault or incorrect
connections of the LVDS cable.
Corrective Actions: Replace or reconnect the LVDS
cable correctly so that video
signals can be supplied to the
panel.
* A full white pattern is a feature of the
TN panel and is displayed when no
video signals are supplied.
Содержание SyncMaster 320TSn-2
Страница 11: ...3 8 3 Disassembly and Reassemble Memo...
Страница 34: ...1 4 1 Precautions Memo...
Страница 40: ...2 6 2 Product specifications Memo...
Страница 43: ...4 3 4 Troubleshooting 4 2 1 Waveform...
Страница 45: ...4 5 4 Troubleshooting 4 3 1 Waveform...
Страница 47: ...4 7 4 Troubleshooting 4 4 1 Waveform...
Страница 49: ...4 9 4 Troubleshooting 4 5 1 Waveform...
Страница 51: ...4 11 4 Troubleshooting 4 6 1 Waveform...
Страница 53: ...4 13 4 Troubleshooting 4 7 1 Screens to Check 16...
Страница 65: ...6 1 6 Wiring Diagram 6 Wiring Diagram 6 1 Wiring Diagram Main...
Страница 66: ...6 2 6 Wiring Diagram 6 2 Wiring Diagram Network...
Страница 72: ...6 8 6 Wiring Diagram 6 8 Wiring Diagram...
Страница 73: ...6 9 6 Wiring Diagram...