User Manual
73
6.7.3 Digital I/O
Digital I/O are digital ports available for input and output at the same time., There are 12 digital
inputs and outputs.
Digital I/O Channel & Input/Output
All 12 channels can be set to input/output. When channels are set to input, if an input signal is
received by even one channel, emergency recording will operate. When they are set to output, if
sensor input is received, it will operate.
In Digital I/O Setup, if you set one of the 12 Digital I/O to [Input], set Input Type to [Emergency]
and turn Digital I/O on, the emergency recording will operate. The macro set in the event
recording is used for the recording. The recording will continue based on the value set in
[Recording After Event] under Event Recording and then stop.
※
SVR-480 does not support Digital I/O.