38_

 

I/O Time Setup

I/O time setup

AUXILIARY INPUT #1 SETUP

Press the 

F

5

 SETUP MENU button.

Use the buttons 

4

 and 

6

 to move to the 

AUX INPUT #1

 item and 

press 

ENT

.

You can make input when the prompt blinks.

Use the keypad to enter the time for each output operation and press 

ENT

.

DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output

The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can 
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 50)
If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time 
unit.

AUXILIARY INPUT #2 SETUP

Press the 

F

5

 SETUP MENU button.

Use the buttons 

4

 and 

6

 to move to the 

AUX INPUT #2

 item and 

press 

ENT

.

You can make input when the prompt blinks.

Use the keypad to enter the time for each output operation and press 

ENT

.

DR : Door relay output
AR : Alarm relay output
T1 : TTL #1 output
T2 : TTL #2 output
BZ : Buzzer output

The output time differs, depending on the time unit.
If the time unit is 0.1 (second), you can specify the value between 0.0 and 9.8 second; if set to 1 (second), you can 
specify between 0 and 98 seconds.
For the time unit, refer to the ‘Time Unit Setup’ under the advanced setup. (see page 50)

If you enter 99 for the value, the product stays in output mode until you change the setting regardless of the time 
unit. 

1.

2.

3.

M

1.

2.

3.

M

3.AUX INPUT#1

D R   A R   T 1   T 2   B Z
0 0   0 0   0 0   0 0   0 0

3.AUX INPUT#1

D R   A R   T 1   T 2   B Z

_ 0   0 0   0 0   0 0   0 0

4.AUX INPUT#2

D R   A R   T 1   T 2   B Z
0 0   0 0   0 0   0 0   0 0

4.AUX INPUT#2

D R   A R   T 1   T 2   B Z

_ 0   0 0   0 0   0 0   0 0

Содержание SSA-S2101

Страница 1: ...dalone RFID Access Controller user manual SSA S2101 imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com ...

Страница 2: ...h water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case immediately disconnect the power source and contact the service center Continued use in such a conditi...

Страница 3: ...e equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 8 9 1 2 Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Insta...

Страница 4: ... Diode Connection 16 I O Connection 18 External Reader Connection INITIALIZATION 20 20 Initializing the system 21 To access the master mode 21 Registering a master ID 22 Name Display 23 User Count Setup 23 Language Setup 24 Date Time Setup 24 Communication Address Setup 25 Baud Rate Setup 25 Factory Defaults READER MODE SETUP 26 26 Reader 1 Mode 26 READER 2 Mode 27 READER 1 Key Input 27 READER 2 K...

Страница 5: ...ct Sensor Setup 38 Auxiliary Input 1 Setup 38 Auxiliary Input 2 Setup 39 Tamper Alarm Output Setup 39 Cut Off Output Setup 40 Duress Mode Output Setup 40 ARM DISARM Output Setup 41 Door Open Timeout Setup 41 Output Setup for Level IDs Accessing READER 1 43 READER 1 Error Output Setup 44 Output Setup for Level IDs Accessing READER 2 45 READER 2 Error Output Setup ADVANCED SETUP 47 47 Time Unit Setu...

Страница 6: ...NFORMATION 62 62 Menu Structure 68 Default Settings ADDITIONAL FEATURES 54 54 Event Memory Setup 54 ID Display 55 WIEGAND Output Setup 55 Voice Volume Setup 56 One Time Read 56 Version Check 57 Input Test 57 Output Test 58 LCD Test 58 Keypad Test 59 READER Test 59 Memory Test 60 Communication Test 61 Input Type Setup ...

Страница 7: ...xternal card reader which is used to control one entrance It determines to allow access by reading data from the internal or external card reader and controls the open close of the door relay and other output settings On an external signal from a sensor or Exit button reception the device relay corresponding to the signal starts operating This product has an independent control system assuring a n...

Страница 8: ...error APB error occurs which will be saved into the internal memory And you can configure to output a signal through a specific pin when such an error occurs Refer to Antipassback Error Output Setup at pages 46 and 49 Arm Disarm As long as the device is in Arm mode the reader ports are all frozen so that no one can get access to the door and any input from the corresponding external pin will not be ...

Страница 9: ...he following items are included in the product package Main Unit Wall Mount Cable X 6 Diode X 2 UF4004 1N4001 4007 Resistor X 4 2 2kΩ 1 4W 3 5 X 40mm screws X 4 3 5 X 12mm screws X 4 3 X 8mm screws X 1 6 X 30mm Plastic Anchor X 4 x Gn Quick Guide Quick Guide ...

Страница 10: ...on when relay 1 becomes active The yellow indicator turns on when relay 2 becomes active Menu Buttons 12 menu buttons F1 F12 are available for use Press a menu button to enter the corresponding menu For the complete list of menus refer to Menu Structure on pages 65 through 70 Input Keys Use these to enter numbers or navigate through the menu 4 6 Left right direction buttons 2 8 Up down direction b...

Страница 11: ...ew 4 2 pin Connector Can be connected to the power cable 5 3 pin Connector Preliminary connector for extension 6 6 pin Connector Can be connected to the I O cable 7 8 pin Connector Can be connected to the relay wiring cable 8 Initialize switch System Initialize switch 9 LED Communication status indicator 10 4 pin Connector Preliminary connector for extension 2 3 4 5 6 7 8 9 10 6 7 11 ...

Страница 12: ...xiliary Input 2 AUX_IN 2 Green with White Stripes Wiegand Data Input 0 WIK_D_IN0 Pink Wiegand Data Input 1 WIK_D_IN1 Sky Blue 8 PIN Connector I O Pins Signal Cable Color Door RELAY NC NC 1 Blue with White Stripes Door RELAY COM COM 1 Gray with Red Stripes Door RELAY NO NO 1 White with Red Stripes Alarm RELAY NC NC 2 Purple with White Stripes Alarm RELAY COM COM 2 White Alarm RELAY NO NO 2 Purple E...

Страница 13: ... Distance Within 3m Belden 9409 18 AWG 2 Conductor Unshielded Maximum Allowable Distance Within 3m 2 Reader power and data External reader This product Belden 9512 22 AWG 4 Conductor Shielded Belden 9514 22 AWG 8 Conductor Shielded 3 Door Contact Sensor Exit Button Sensor Input Input This product Belden 9512 22 AWG 4 Conductor Shielded Belden 9514 22 AWG 8 Conductor Shielded ...

Страница 14: ...or the screws Drill at least 4 of 6 32 holes Drill a 1 2 hole on the center of the wall mount Use 4 screws to fix the template to an appropriate point Arrange the cables through the center hole Connect the cable and use one screw on the bottom of the wall mount to fix it to the product Do not install the product on a metal wall Otherwise this will cause malfunction due to radio frequency interferenc...

Страница 15: ...ctor was turning on and off If you do not connect a bypass diode to the relay the surge voltage will cause damage to the electric circuit of the controller To reduce this surge it is recommended to connect a bypass diode between the devices Lock Alarm GND DC12V Cathode Anode 1N4004 1N4007 or equiv 1 3 2 6 5 4 7 9 8 ESC 0 ENT F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Mon 12 12 2009 10 30 20 183 003 ...

Страница 16: ...ellow with red stripes Connect the other end of the door contact sensor to GND Auxiliary Input Device Connection auxiliary input 1 green auxiliary input 2 green with white stripes Connect one end of the auxiliary input device to auxiliary input 1 or auxiliary input 2 Connect the other end of the auxiliary input device to GND 1 2 1 2 1 2 1 2 1 3 2 6 5 4 7 9 8 ESC 0 ENT F1 F2 F3 F4 F5 F6 F7 F8 F9 F1...

Страница 17: ...2V Connect the relay NO line white with red stripes for locking the door to the plus line of the door lock Connect the minus line of the door lock to GND Alarm Connection Alarm Relay Connect the relay COM white for the alarm device to DC 12V Connect the relay NO line purple for the alarm device to the plus line of the alarm device Connect the minus line of the alarm device to GND 1 2 3 1 2 3 1 2 3...

Страница 18: ... pink line Connect the Wiegand data input line 1 of the proximity reader to the sky blue line For a list of compliant readers external readers see the followings SSA S2100 Standard 26bit Wiegand format proximity reader Standard 26bit Wiegand 8bit Burst format proximity keypad reader SSA S2101 Standard 34bit Wiegand format proximity reader Standard 34bit Wiegand 8bit Burst format proximity keypad r...

Страница 19: ...work system Set a unique communication address COMM ADDR for each unit Install and launch the application SAMS 1 2 3 1 3 2 6 5 4 7 9 8 ESC 0 ENT F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Mon 12 12 2009 10 30 20 183 003 1 3 2 6 5 4 7 9 8 ESC 0 ENT F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Mon 12 12 2009 10 30 20 183 003 1 3 2 6 5 4 7 9 8 ESC 0 ENT F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Mon 12 12 2009 10 ...

Страница 20: ...press 0 When the Initializing is done you will move to the standby screen Note that the initialization process will restore all previous settings to the factory default System Initialization in Master Mode You can Initialize the system through authentication of the master card For entering the master mode see page 24 Press the F8 SETUP MENU button Use the buttons 4 and 6 to move to the SYSTEM INIT...

Страница 21: ...ster ID you can not get access using 00000000 The master number for SSA S2101 is 0000000000 10 digits REGISTERING A MASTER ID To register a master card Press the F7 SETUP MENU button Use the buttons 4 and 6 to move to the MASTER ID REG item and press ENT Select a master ID index to register and press ENT To select a card press 1 Place the master card to register on the product Enter the password f...

Страница 22: ...ftware only and accepts only alphabetic letters up to 8 characters By using the unit you can register a new user but cannot enter the user s name In case of such a user s accessing no name will be displayed Press the F3 SETUP MENU button Use the buttons 4 and 6 to move to the NAME DISPLAY item and press ENT Use the buttons 4 and 6 to select USE or NOT USE and press ENT USE Name Display is enabled ...

Страница 23: ...user count 10 000 The max user count will be set to 10 000 20 000 The max user count will be set to 20 000 Before setting the user count you must initialize the system LANGUAGE SETUP Press the F1 SETUP MENU button Use the buttons 4 and 6 to move to the LANGUAGE item and press ENT Use the buttons 4 and 6 to select a max user count ENGLISH ESPANOL PORTUGUESE 한국어 The default language is ENGLISH By de...

Страница 24: ...ttings Enter each value for Date Time to fit the respective digits COMMUNICATION ADDRESS SETUP Press the F1 SETUP MENU button Use the buttons 4 and 6 to move to the COMM ADDR SET item and press ENT Enter the 3 digit communication address number Ex if you set the COMM ADDR to 12 press 012 for that When done press ENT to save your settings The default address is set to 000 Select a number between 000...

Страница 25: ... a problem with the communication check the followings first Check the communication addresses for this product and the host PC software Check the baud rate settings of each of the host PC and this product Check the communication port and cable Check the host PC for the port settings FACTORY DEFAULTS All menu settings will return to the factory default The memory is not deleted Press the F8 SETUP M...

Страница 26: ...he ID number When done press ENT to save your settings READER 2 MODE READER 2 is an external reader for exit Press the F1 SETUP MENU button Use the buttons 4 and 6 to move to the READER 2 MODE item and press ENT Use the buttons 4 and 6 to select a reader mode 2 modes are available for your choice ID ONLY In this mode you can get access only with the proximity card or ID number ID P W In this mode ...

Страница 27: ... ENT to save your settings READER 2 KEY INPUT This enables you to use the keypad of READER 2 numeric keypad of the external device to enter the ID If you want to use the registered ID card number or PIN to get access set this mode to USE Press the F1 SETUP MENU button Use the buttons 4 and 6 to move to the RD 2 KEY INPUT item and press ENT Use the buttons 4 and 6 to select the use of the keypad of...

Страница 28: ...s to enter an ID Place the card on the main unit to display the card ID on the screen Use the keypad to enter the number and press ENT Enter the password and press ENT ID registration is completed Registering in Quick mode will set TA and TB to 00 and RD MA MB LV to 0 Refer to page 31 1 2 3 4 5 QUICK MODE 1 REGISTRATION 1 REGISTRATION ID _ ENTER PIN PUT ID CARD 1 REGISTRATION ID 12345678 PASS WORD...

Страница 29: ...0 Normal card 1 2 person authentication administrator 2 2 person authentication visitor 3 Set ARM DISARM 4 Missing card RD Reader assignment to the card user NO Description 0 READER 1 READER 2 assigned 1 READER 1 assigned 2 READER 2 assigned 3 READER 1 READER 2 assigned Item Description MA READER 1 operation mode for the registered user NO Description 0 System Operation Mode 1 ID mode 2 ID P W MB ...

Страница 30: ... press ENT Set each of PW TA TB C RD MA MB LV For more information about each item refer to ID Registration Items on page 32 ID registration is completed You can use the keypad to enter the ID in the following digits depending on the model PIN Range SSA S2100 Numeric letters in 4 8 digits Ranges from 00000001 to 99999999 SSA S2101 Numeric letters in 4 8 or 10 digits Ranges from 0001 to 99999999 00...

Страница 31: ...WING THE ID LIST You can check the list of IDs registered with the product Press the F7 SETUP MENU button Use the buttons 4 and 6 to move to the ID LIST item and press ENT The list of registered IDs appears on the screen The list of registered IDs appears on the screen ID INDEX Number of registered items ID ID number C ID permission code PW password TA Time schedule of READER 1 TB Time schedule of...

Страница 32: ... The number of registered IDs will be displayed in 5 digits TO REMOVE ALL REGISTERED IDs You can remove all of the registered user IDs Press the F8 SETUP MENU button Use the buttons 4 and 6 to move to the ALL ID CLEAR item and press ENT Press the button 1 to delete all registered IDs To cancel the work press the button 0 Please upload the ID data to the host PC before deletion just for backup purp...

Страница 33: ...umbers for the Duress mode password whose default is 00 If it is set to USE enter the two digit Duress password and press ENT this will open the door normally but the Duress alarm signal is transmitted to the host PC Press the F2 SETUP MENU button Use the buttons 4 and 6 to move to the DURESS MODE item and press ENT Use the buttons 4 and 6 to select USE NOT USE Duress Mode is disabled USE If set t...

Страница 34: ...stalled on the entrance door ARM DISARM With the ARM DISARM code active you can set the ARM mode by entering the ARM code and presenting the card assigned Code 3 in registration of a person who has the ARM DISARM permissions In this mode all connected readers will not take the card input any further To release the ARM mode enter the DISARM code and present the ARM DISARM card Press the F3 SETUP ME...

Страница 35: ...or Registering the ID TO CHECK THE NUMBER OF EVENTS You can check the total number of events stored in the memory When an event is stored in the memory the count will increase accordingly The total number of events is 20 000 Once a specific event is uploaded successfully to the host PC it will be removed from the internal memory Press the F7 SETUP MENU button Use the buttons 4 and 6 to move to the ...

Страница 36: ...time schedules 01 10 all holiday schedules 01 10 holiday codes and time schedules for reader 1 and reader 2 modes can be deleted With the ENT button pressed press the 1 button to remove all time schedules or press the 0 button to cancel the work Press the F8 SETUP MENU button Use the buttons 4 and 6 to move to the T S CLEAR item and press ENT Press the button 1 to remove all time schedules To canc...

Страница 37: ...opened without through the normal authentication process The Door Contact sensor should have been installed Press the F5 SETUP MENU button Use the buttons 4 and 6 to move to the DOOR CONTACT item and press ENT You can make input when the prompt blinks Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 output T2 TTL 2 output ...

Страница 38: ...t AUXILIARY INPUT 2 SETUP Press the F5 SETUP MENU button Use the buttons 4 and 6 to move to the AUX INPUT 2 item and press ENT You can make input when the prompt blinks Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 output T2 TTL 2 output BZ Buzzer output The output time differs depending on the time unit If the time uni...

Страница 39: ...n set the output options when any of the input line is cut off The input cutoff check should have been activated see page 56 Press the F5 SETUP MENU button Use the buttons 4 and 6 to move to the CUT OFF ALARM item and press ENT You can make input when the prompt blinks Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 outpu...

Страница 40: ... DISARM OUTPUT SETUP You can specify the output time for ARM DISARM mode Press the F5 SETUP MENU button Use the buttons 4 and 6 to move to the ARM DISARM SET item and press ENT You can make input when the prompt blinks Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 output T2 TTL 2 output BZ Buzzer output ARM DISARM must ...

Страница 41: ...OUTPUT SETUP FOR LEVEL IDs ACCESSING READER 1 Output Setup for the event of Level 1 IDs accessing the READER 1 Press the F6 SETUP MENU button Use the buttons 4 and 6 to move to the RD1 ID OK LV1 item and press ENT You can make input when the prompt blinks Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 output T2 TTL 2 out...

Страница 42: ...ove to the RD1 ID OK LV3 item and press ENT The operation time for each output is the same as in Output Setup for Level 1 IDs Accessing READER 1 above see page 44 Output Setup for Level 3 IDs Accessing READER 1 Press the F6 SETUP MENU button Use the buttons 4 and 6 to move to the RD1 ID OK LV4 item and press ENT The operation time for each output is the same as in Output Setup for Level 1 IDs Acce...

Страница 43: ...alue the product stays in output mode until you change the setting regardless of the time unit READER 1 Time Schedule Error Output Setup Press the F6 SETUP MENU button Use the buttons 4 and 6 to move to the RD1 T S ERROR item and press ENT The operation time for each output is the same as in READER 1 ID Error Output Setup above Time schedule must be configured before See Page 51 for Time Schedule ...

Страница 44: ...under the advanced setup see page 50 If you enter 99 for the value the product stays in output mode until you change the setting regardless of the time unit Output Setup for the event of Level 2 IDs accessing the READER 2 Press the F6 SETUP MENU button Use the buttons 4 and 6 to move to the RD2 ID OK LV2 item and press ENT The operation time for each output is the same as in Output Setup for Level...

Страница 45: ...d Use the keypad to enter the time for each output operation and press ENT DR Door relay output AR Alarm relay output T1 TTL 1 output T2 TTL 2 output BZ Buzzer output The output time differs depending on the time unit If the time unit is 0 1 second you can specify the value between 0 0 and 9 8 second if set to 1 second you can specify between 0 and 98 seconds For the time unit refer to the Time Un...

Страница 46: ...ust be configured before See Page 51 for Time Schedule Setup READER 2 Antipassback Error Output Setup Press the F6 SETUP MENU button Use the buttons 4 and 6 to move to the RD2 APB ERROR item and press ENT The operation time for each output is the same as in READER 2 ID Error Output Setup above see page 48 APB mode must be enabled before See Page 51 for AntiPassBack Mode 1 2 M 1 2 M 13 RD2 T S ERRO...

Страница 47: ...will affect all I O time settings OUTPUT TIME SCHEDULE ID The Output T S ID feature is used in particular in opening the door for a specified time period in a specific time schedule However you can set it not to open the door after the specified time unless a user entry i e entering the ID is attempted The closing time is of course the end point of the specified time period Press the F2 SETUP MENU but...

Страница 48: ...utput Setup at pages 46 and 49 TIME SCHEDULE SETUP You can set a total of 10 Time Schedule codes The default code is 00 which is used to allow unlimited access Each Time Schedule code has 8 programmable days Sunday through Saturday and a holiday each of which has 5 time intervals You can check information such as Time Schedule code day of the week time interval and current Time Schedule setting A ...

Страница 49: ...n Use the buttons 4 and 6 to move to HOLIDAY SET and press ENT Use the 4 6 2 and 8 buttons to select HOLIDAY CODE and DAY NO and press ENT HOLIDAY CODE 01 10 DAY NO 001 100 Use the numeric buttons to enter 4 digit month day and press ENT If the entry is incorrect the INVALID NUMBER message will appear Repeat steps 3 through 4 to set other holiday schedule codes Upon completion of all holiday sched...

Страница 50: ...NT to store the Holiday Index to the memory Press the F4 SETUP MENU button Use the buttons 4 and 6 to move to HOLIDAY CODE and press ENT Use the buttons 4 and 6 to select Time Schedule and press ENT T S Time Schedule CODE 01 10 Use the numeric buttons to enter 2 digit holiday code HOLIDAY CODE 01 10 If the entry is invalid the INVALID NUMBER message will appear Repeat steps 3 through 4 above to se...

Страница 51: ...e and press ENT T S Time Schedule CODE 00 10 If the entry is incorrect the INVALID NUMBER message will appear The T S Code 00 indicates no Time Schedule is to be applied READER 2 Mode Time Schedule There are 2 reader modes in READER 2 including ID Mode and ID P W Mode Unless otherwise specified all registered users should be authenticated to the reader mode in use However you may allow entry with c...

Страница 52: ... INVALID NUMBER message will appear The T S Code 00 indicates no Time Schedule is to be applied OUTPUT TIME SCHEDULE SETUP You can link a Time Schedule Code to each output The default Time Schedule Code for every output is 00 which means no Time Schedule is applied to them Changing these settings can be very useful when you want to leave the door open during a certain time period Press the F5 SETU...

Страница 53: ...setting is 00 To enable the cut off check function change the setting to 01 In case of cut off detected at the input while the cut off check enabled the corresponding output signal is given as per Cut Off Output Setup See Page 42 Press the F5 SETUP MENU button Use the buttons 4 and 6 to move to CUT OFF SET and press ENT Use the numeric buttons to enter 00 or 01 for each input 00 The Input Cut Off ...

Страница 54: ...g is USE ID DISPLAY Press the F2 SETUP MENU button Use the buttons 4 and 6 to move to the ID DISPLAY item and press ENT Use the buttons 4 and 6 to select MESSAGE or ID MESSAGE and press ENT MESSAGE Instead of a text message and the user ID the text message of will appear on the screen ID MESSAGE The User ID along with a text message will appear on the screen ÂÂÂÂÂÂÂÂ ACCESS GRANTED MYID 12 12 16 2...

Страница 55: ... When it is set to USE the TTL 1 and TTL 2 outputs are disabled except for WIEGAND Outputs VOICE VOLUME SETUP Press the F3 SETUP MENU button Use the buttons 4 and 6 to move to VOICE VOLUME and press ENT When done press ENT to save your settings You can adjust the volume of the voice in 5 levels from 0 mute to 4 maximum Adjust the volume level to 0 to disable voice output If you enter a value highe...

Страница 56: ... card For unregistered cards the authentication process will be attempted repeatedly When another registered card is successfully authenticated within 30 seconds from the first normal authentication by a registered card it is possible to authenticate the first card again not requiring the time lag of 30 seconds NOT USE Continuous re authentication of a registered card is enabled The default settin...

Страница 57: ... for each output Press the F9 SETUP MENU button Use the buttons 4 and 6 to move to OUTPUT TEST and press ENT Press ENT to turn ON OFF the DOOR REALY ALARM RELAY TTL 1 TTL 2 BUZZER in sequence DOOR REALY ON OFF ALARM RELAY ON OFF TTL 1 ON OFF TTL 2 ON OFF BUZZER ON OFF Press any key to move to the parent menu The first two tests verify if the output relays Door Relay and Alarm Relay are working prop...

Страница 58: ...NT Check the SAMSUNG logo The last date the firmware is amended and the version information is displayed KEYPAD TEST Press the F9 SETUP MENU button Use the buttons 4 and 6 to move to the KEYPAD TEST item and press ENT When the Keypad Test screen appears try to press each key one by one The depressed key will disappear from the screen ESC on the keypad ENT on the keypad 1 2 3 1 2 3 4 LCD TEST LAST U...

Страница 59: ...the F9 SETUP MENU button Use the buttons 4 and 6 to move to the MEMORY TEST item and press ENT Press ENT to start the test Please see the pictures below for the screens when the test has succeeded and failed TEST PASSED PRESS ANY KEY If the test has succeeded If the test has failed TEST FAILED PRESS ANY KEY Press any key to move to the parent menu If the Data Memory has a problem the TEST FAILED m...

Страница 60: ... and 6 to move to the COMM TEST item and press ENT TX DATA Transmit Data RX DATA Receive Data Press ENT to start the test Please see the pictures below for the screens when the test has succeeded and failed TEST PASSED PRESS ANY KEY If the test has succeeded If the test has failed TEST FAILED PRESS ANY KEY Press any key to move to the parent menu If the communication is malfunctioning the TEST FAI...

Страница 61: ...O Normal Open open is normal NC Normal Close close is normal EX Exit Button DC Door Open Sensor I 1 Aux Input 1 I 2 Aux Input 2 TP Tamper Input If values other than 00 or 01 are entered the error message of INVALID NUMBER will appear and the values you entered will not be saved Check the operation type of the input device that is connected to the input port If the operation type is set incorrectly...

Страница 62: ...0 99 NOT USE USE NOT USE USE NOT USE USE ALL CLEAR UNIT 1 SEC UNIT 0 1 SEC MESSAGE ID MESSAGE USE NOT USE NOT USE USE F2 button EVENT MEMORY ID DISPLAY TIME UNIT OUTPUT T S ID APB MODE DURESS MODE WIEGAND OUTPUT OPEN ALR TIME Menu Structure of the F1 button You can set Language Date Time and READER modes Menu Structure of the F2 button You can set Event Memory ID Display Time Unit Setup Output Tim...

Страница 63: ...eekly INTERVAL 1 5 T S CODE 01 10 HOLIDAY CODE 01 10 HOLIDAY CODE 01 10 DAY NO 001 100 F4 button TIME SCHEDULE HOLIDAY SET HOLIDAY CODE RD1 MODE T S RD2 MODE T S VOICE T S Menu Structure of the F3 button You can set Voice Volume Arm Disarm Two Men Operation One Time Read Number of Users and Name Display Menu Structure of the F4 button You can set Time Schedule Holiday Holiday Code READER 1 and 2 M...

Страница 64: ...LARM ARM DISARM OUT DOOR TIME OUT OUTPUT T S INPUT T S CUT OFF SET INPUT TYPE Menu Structure of the F5 button You can set Exit Key Output Door Contact Sensor Aux Input 1 and 2 Tamper Alarm Output Cut Off Output Duress Alarm Output Arm Disarm Output Door Open timeout Output Input Output Time Schedule Input Cut Off Check and Input Type ...

Страница 65: ...OR RD2 ID OK LV1 RD2 ID OK LV2 RD2 ID OK LV3 RD2 ID OK LV4 RD2 ID ERROR RD2 T S ERROR RD2 APB ERROR RD1 APB ERROR Menu Structure of the F6 button You can set Output for Accessible levels for READER 1 and 2 ID READER 1 and 2 ID Error Output READER 1 and 2 Time Schedule Error Output READER 1 and 2 Antipassback Error Output ...

Страница 66: ...T CARD KEY F7 button REGISTRATION ID DELETE ID LIST MASTER ID REG REG ID COUNT EVENT COUNT Menu Structure of the F7 button You can register or delete IDs and register the master ID You can also view the ID list ID count and event count Menu Structure of the F8 button You can initialize the master mode and delete the entire events IDs Master ID and Time Schedules ...

Страница 67: ...EST Menu Structure of the F9 button You can check the system version You can also test the input output LCD keypad reader memory and communication status Menu Structure of the F12 button You can easily register or delete IDs without going through a complex setup procedure F12 button QUICK MODE REGISTRATION QUICK MODE ID DELETE ...

Страница 68: ...00 00 11 Input Time Schedule 00 00 00 00 00 12 Cut Off Check 00 00 00 00 00 13 Input Type 00 00 00 00 00 Index No 1 9 The values indicate the operating time of each output for the input signal Index No 10 The values indicate the time schedule code index applied to each output Index No 11 The values indicate the input port 1 Exit Button 5 Tamper S W Each value indicates the code of Time Schedule to...

Страница 69: ... 00 00 00 00 5 Reader 1 ID Error 00 03 00 00 00 6 Reader 1 T S Error 00 03 00 00 00 7 Reader 1 APB Error 00 03 00 00 00 8 Reader 2 ID OK LV1 03 00 00 00 00 9 Reader 2 ID OK LV2 05 00 00 00 00 10 Reader 2 ID OK LV3 05 00 00 00 00 11 Reader 2 ID OK LV4 05 00 00 00 00 12 Reader 2 ID Error 00 03 00 00 00 13 Reader 2 T S Error 00 03 00 00 00 14 Reader 2 APB Error 00 03 00 00 00 Index No 1 14 The values...

Страница 70: ...lization process is completed the system will be operating on the normal mode and the screen will display the SAMSUNG logo Date and Time information 3 If the trouble persists after following the procedures above contact a designated service center No problem with accessing by card but cannot access via a manual PIN input 1 Check whether a beep sounds when you press a key If a beep sounds the probl...

Страница 71: ...r if the time schedule code is set to value between 01 and 10 and the present time is within the time zone of the selected schedule If the wrong time schedule is selected change it to 00 this can be set by PC software 4 Check the Tamper switch of the unit 5 If the trouble persists after following the procedures above contact a designated service center The communication between the controller and ...

Страница 72: ... DC5V Rating MAX 20mA 1ea 26bit Wiegand Output Supported by TTL Output 1ea 34bit Wiegand Output Supported by TTL Output LED Indicator 3 LED Indicators Red Green and Yellow Beeper Piezo Buzzer LCD Graphic LCD 128 x 64 dots 72 5mm x 39 5mm 2 85 x 1 56 View area Keypad 24 key Numeric Keypad with Back Lighting 12 Function Key included LCD Display Language English Spanish Portugal Korean Selectable Voi...

Страница 73: ...Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environ...

Отзывы: