background image

6_

 

product introduction

product introduction

Input Port Format Setup

15 input ports are provided by default. For these ports, you can specify if the format of the incoming signal is 
blocked (NO) or connected (NC) in normal operation. This setting will make all ports operate same regardless of the 
output status of the input device.

Time Scheduling

You can specify a time range during which a specifi c operation is performed. You can specify a specifi c time range 
for a schedule code, which will be transferred to the applicable device. You can specify up to 5 different time 
intervals for a day, ranging from Monday to Sunday including holidays. Each time schedule code can produce a 
single different (or same) holiday code.

Door Open Alarm and Forced Door Open Alarm

The Door Open Alarm function notifi es the administrator that the door is still open if a door stays open after the 
normal door open time and the standby time. (The output signal can be transferred via the output port, data on any 
abnormal state will be stored in memory, which will be transferred upon request from the PC software. The Forced 
Door Open Alarm function produces an alert when the door is forced to open and makes an alert again if the door 
is still open after the timeout.

I/O Settings

This product is equipped with 15 input ports, 12 relay output ports, and 3 TTL output ports. You can use the 
input ports to receive signals from the Exit button and the fi re sensor, and utilize this product to meet various 
situations such as attaching the door lock to any of the 12 relays. You can also set the output time for these 
output ports.

Holiday Setup

You can specify a holiday (legal holiday or bi-weekly holiday) excluding Sunday. You can specify up to 100 holidays 
for a single holiday code. (Access can be permitted only for an allowable time range according to your time 
schedule setting) A holiday code can be assigned to the time schedule code.

ARM/DISARM

In the condition where the ARM/DISARM code is specifi ed, if you enter the ARM/DISARM code and present the 
card of the administrator (with master permissions) to the reader, the device triggers the alarm mode where you 
can control the output signal in sync with the security system. In this mode, all connected readers will not take the 
card input any further.

Duress Mode

This is used in a situation where you should open the door inevitably by a robber insisting to do so. Open the door 
by entering the two-digit duress alarm password and pressing the 

 button before presenting the registered card 

(or recognizing the card number), in the meantime this forcibly duress situation will be notifi ed to the PC application.

Two Men Operation Mode

This will allow access by visitors only under the control of the visitor guide.
Access will be permitted only if two cards are presented within a specifi ed time (10 seconds).

Dual Door Time Control

This allows you to specify two different settings for the entrance door control time according to the passers-by.
However, this can not be enabled with the ARM/DISARM function at the same time.

Data Maintenance

In the event of power failure, the controller retains all card information and the access/alert history (event data) until 
it is damaged on the memory.

You can use the application program (SAMS Basic) to confi gure all theses settings to your preference.

J

Содержание SSA-P400

Страница 1: ...ol Panel user manual SSA P400 SSA P400T SSA P401 SSA P401T imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsung...

Страница 2: ...injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers lled with water on top of the controller Doing so may cause personal injury due to re electric shock or fal...

Страница 3: ...vided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacle...

Страница 4: ...ECTION 13 13 Connecting the termination resistor and diode 14 Earth grounding the communication cables 15 Power Reader and I O Connection 18 Communication Line Connection INITIALIZATION 22 22 System I...

Страница 5: ...ow access by reading data from the card reader and controls the open close of the door relay and enables you to change other output settings Upon receipt of an incoming external input signal sensor or...

Страница 6: ...o set the output time for these output ports Holiday Setup You can specify a holiday legal holiday or bi weekly holiday excluding Sunday You can specify up to 100 holidays for a single holiday code Ac...

Страница 7: ...English7 PRODUCT INTRODUCTION WHAT S INCLUDED Check if the following items are included in the product package x Gn Main Unit Quick Guide CD Manual Diode x12 UF4004 1N4001 4007...

Страница 8: ...stem Initialization Switch Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both switches will stop the beep and restarts the system af...

Страница 9: ...onnection Port Optional item 16 TCP IP Module Connection Port The TCP IP module is optional so it is not provided by default Communication can be established using the built in TCP IP module Communica...

Страница 10: ...red indicator turns on in the normal power supply condition 3 Main Board Connection Port Connector used to connect to the main board 4 Output Relay 5 Port Output port 5 5 Output Relay 6 Port Output po...

Страница 11: ...13 14 INPUT 14 Input port 14 15 INPUT 15 Input port 15 16 Output Relay 9 Port Output port 9 FORM C 17 Output Relay 10 Port Output port 10 FORM C 18 Output Relay 11 Port Output port 11 FORM C 19 Outpu...

Страница 12: ...Door Lock Alarm Device Lock Alarm Device Belden 9409 18AWG 2 Conductor Unshielded 5 RS 232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair Shielded 6 RS 485 Cable Device Device Device Conv...

Страница 13: ...you connected an inductor door lock or alarm device to the output relay there should occur a voltage surge while the inductor was between turning on and turning off If you do not connect a bypass dio...

Страница 14: ...s current ow will introduce some noise and interference to communications It is recommended to connect ONLY one end of the shield wire of the communication cable to the grounding system If you can loc...

Страница 15: ...a 1 line of the reader to its port data 1 D1 Door Number External Reader Internal Reader Exit Button Two Door Control 1 Reader 1 Reader 2 None 2 Reader 3 Reader 4 None Three Door Control 1 Reader 1 Re...

Страница 16: ...e input port Door 1 Input 2 Door 2 Input 4 of the door sensor Connect the other line NC of the door sensor to GND Door Number Exit Button Door Open Sensor Note Two Door Control 1 Input 1 Input 2 2 Inp...

Страница 17: ...Alarm Device Connection Door 1 Alarm Relay 2 Door 2 Alarm Relay 4 Connect the COM line of the alarm device relay to DC 12V Connect the plus line of the alarm device to the NO line of the alarm device...

Страница 18: ...he 9 pin connector for RS 232 communications as follows Connect RS 232 TX to pin 2 of the 9 pin connector Connect RS 232 RX to pin 3 of the 9 pin connector Connect RS 232 GND to pin 5 of the 9 pin con...

Страница 19: ...he RX port of the converter Connect RS 422 TX to the RX port of the converter Connect RS 422 RX to the TX port of the converter Connect RS 422 RX to the TX port of the converter Connect the 9 pin conn...

Страница 20: ...to RX of other one Set a unique board ID for each product Follow the guidelines below to make connection between the terminal device and the RS 422 9 pin connector of the RS 422 RS 232 converter Conne...

Страница 21: ...CP IP Connection Connect the LAN cable to the TCP IP RJ 45 jack as shown applicable only to SSA P400T SSA P401T Connect the RJ45 jack of the unit to the RJ45 plug the LAN cable of the network system S...

Страница 22: ...ialize switch on the upper right corner and press both switches simultaneously Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both sw...

Страница 23: ...itches are defaulted to OFF Each switch has a unique value and the board ID is the sum of the values of the switches You can specify between 0 and 255 for the board ID Refer to the example below for t...

Страница 24: ...ve of an internal circuit Contact the nearest customer service for technical assistance The RF card works normally but the key input for the card number using the keypad does not work properly Use the...

Страница 25: ...able of the converter RX Port TX RX TX GND GND TX RX TX RX Rs 422 Multi Unit Communication SSA P400 SSA P400 RS 232 RS 422 PC RX RX TX Connected to the RS 232 cable of the converter RX RX TX TX TX RX...

Страница 26: ...t Burst for PIN Door Open Time 00 99 Sec Default 3Sec Communication RS232 RS422 RS485 RS232 RS422 RS485 TCP IP RS232 RS422 RS485 RS232 RS422 RS485 TCP IP Baud Rate bps 9 600bps Input Port 15ea Output...

Страница 27: ...aste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that...

Отзывы: