Samsung SSA-P400 Скачать руководство пользователя страница 5

English

5

PRODUCT INTRODUCTION

FEATURES

State-of-the-art Access Controller

SSA-P400(T)/SSA-P401(T) is a state-of-the-art door access controller device that provides a high level security 
system in an affordable price, meeting the needs in the security industry.
SSA-P400(T)/SSA-P401(T) can control access of 2-4 doors with simple manipulation and high level stability as well 
as its affordable cost. 
You can specify up to 1000 ~ 20,000(30,000/ 40,000/50,000) instances of card registration to your preference, 
which you can delete or change as necessary. The built-in event memory can save up to 20,000 ~ 29,500(14,000/
8,000/3,000) instances of entires and alerts according to the number of registered cards.
You can connect a wide range of readers via the 4 reader ports, and operate the reader in either RF Card or RF 
Card + PW mode.
15 independent input ports can be used to connect to various devices such as Exit Button, Door Contact Sensors, 
PIR Sensors, and Window Breakage Sensors to reinforce security.
You can use the keypad (optional) to confi gure your settings with easy.
You can establish the independent or network connection via RS-232 or RS-422 communications. SSA-P400(T)/
SSA-P401(T) is equipped with a built-in TCP/IP module, which enables you to establish LAN communications. All 
settings including card registration information, I/O settings, Real Time Clock, Time Schedules and all Event 
Transaction Reports can be downloaded /uploaded from/to the host computer with software supporting a variety 
of reporting formats.
Installed and managed inside the security zone for preventing the risk of damage, SSA-P400 (P401) can implement 
a high level security access control system with multiple control options, best fi t for access control and time & 
attendance management.

Standalone Operation

By connecting to 4 card readers, you can use this product to control the access of the maximum of 4 doors. This 
controller determines to allow access by reading data from the card reader, and controls the open/close of the 
door relay and enables you to change other output settings. Upon receipt of an incoming external input signal 
(sensor or Exit button), it launches an output device such as the relay. This controller has an independent control 
system, assuring a normal operation regardless of problems on any other systems and, not affecting them in the 
reverse situation.

Anti-Pass Back

A door has two card readers installed: one for the entrance, and the other for the exit, so anyone who enters 
should recognize his/her card on the reader at the entrance time before he can exit normally. If a person does not 
go under the card recognition process and just follows another person’s way inside the door, the person is not 
allowed to exit when he/she recognizes the access card on exit card reader, and the anti-pass-back error (APB 
error) occurs which will be saved into the internal memory. And you can confi gure to output a certain signal through 
a specifi c port if such an error occurs. (Make your setting using the Application program (controlled access, time 
and attendance management, etc) – I/O Setup – APB Error) You can use Anti-Pass Back for controlling two doors 
independently or in synchronization with each other. 

Computer-based Management

All records of authorized or unauthorized accesses and any external signal will be saved in the internal memory. 
You can download such data onto your computer according to the specifi ed communications protocol. With the 
downloaded data, you can store, process, and create a report based on your query (access and alert details, etc) 
on the central computer.

Door Count Setup (2/3/4 doors)

As it is equipped with 4 card readers, you can use this product to control the access on a maximum of 4 doors. 
For controlling 2 doors, install reader 1 and reader 2 on door 1 while installing reader 3 and reader 4 on door 2. For 
controlling 3 doors, install reader 1 and reader 2 on door 1 while installing reader 3 on door 2, and reader 4 on 
door 3. For controlling 4 doors, install one reader on each door, totalling 4.

product introduction

Содержание SSA-P400

Страница 1: ...ol Panel user manual SSA P400 SSA P400T SSA P401 SSA P401T imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsung...

Страница 2: ...injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers lled with water on top of the controller Doing so may cause personal injury due to re electric shock or fal...

Страница 3: ...vided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacle...

Страница 4: ...ECTION 13 13 Connecting the termination resistor and diode 14 Earth grounding the communication cables 15 Power Reader and I O Connection 18 Communication Line Connection INITIALIZATION 22 22 System I...

Страница 5: ...ow access by reading data from the card reader and controls the open close of the door relay and enables you to change other output settings Upon receipt of an incoming external input signal sensor or...

Страница 6: ...o set the output time for these output ports Holiday Setup You can specify a holiday legal holiday or bi weekly holiday excluding Sunday You can specify up to 100 holidays for a single holiday code Ac...

Страница 7: ...English7 PRODUCT INTRODUCTION WHAT S INCLUDED Check if the following items are included in the product package x Gn Main Unit Quick Guide CD Manual Diode x12 UF4004 1N4001 4007...

Страница 8: ...stem Initialization Switch Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both switches will stop the beep and restarts the system af...

Страница 9: ...onnection Port Optional item 16 TCP IP Module Connection Port The TCP IP module is optional so it is not provided by default Communication can be established using the built in TCP IP module Communica...

Страница 10: ...red indicator turns on in the normal power supply condition 3 Main Board Connection Port Connector used to connect to the main board 4 Output Relay 5 Port Output port 5 5 Output Relay 6 Port Output po...

Страница 11: ...13 14 INPUT 14 Input port 14 15 INPUT 15 Input port 15 16 Output Relay 9 Port Output port 9 FORM C 17 Output Relay 10 Port Output port 10 FORM C 18 Output Relay 11 Port Output port 11 FORM C 19 Outpu...

Страница 12: ...Door Lock Alarm Device Lock Alarm Device Belden 9409 18AWG 2 Conductor Unshielded 5 RS 232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair Shielded 6 RS 485 Cable Device Device Device Conv...

Страница 13: ...you connected an inductor door lock or alarm device to the output relay there should occur a voltage surge while the inductor was between turning on and turning off If you do not connect a bypass dio...

Страница 14: ...s current ow will introduce some noise and interference to communications It is recommended to connect ONLY one end of the shield wire of the communication cable to the grounding system If you can loc...

Страница 15: ...a 1 line of the reader to its port data 1 D1 Door Number External Reader Internal Reader Exit Button Two Door Control 1 Reader 1 Reader 2 None 2 Reader 3 Reader 4 None Three Door Control 1 Reader 1 Re...

Страница 16: ...e input port Door 1 Input 2 Door 2 Input 4 of the door sensor Connect the other line NC of the door sensor to GND Door Number Exit Button Door Open Sensor Note Two Door Control 1 Input 1 Input 2 2 Inp...

Страница 17: ...Alarm Device Connection Door 1 Alarm Relay 2 Door 2 Alarm Relay 4 Connect the COM line of the alarm device relay to DC 12V Connect the plus line of the alarm device to the NO line of the alarm device...

Страница 18: ...he 9 pin connector for RS 232 communications as follows Connect RS 232 TX to pin 2 of the 9 pin connector Connect RS 232 RX to pin 3 of the 9 pin connector Connect RS 232 GND to pin 5 of the 9 pin con...

Страница 19: ...he RX port of the converter Connect RS 422 TX to the RX port of the converter Connect RS 422 RX to the TX port of the converter Connect RS 422 RX to the TX port of the converter Connect the 9 pin conn...

Страница 20: ...to RX of other one Set a unique board ID for each product Follow the guidelines below to make connection between the terminal device and the RS 422 9 pin connector of the RS 422 RS 232 converter Conne...

Страница 21: ...CP IP Connection Connect the LAN cable to the TCP IP RJ 45 jack as shown applicable only to SSA P400T SSA P401T Connect the RJ45 jack of the unit to the RJ45 plug the LAN cable of the network system S...

Страница 22: ...ialize switch on the upper right corner and press both switches simultaneously Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both sw...

Страница 23: ...itches are defaulted to OFF Each switch has a unique value and the board ID is the sum of the values of the switches You can specify between 0 and 255 for the board ID Refer to the example below for t...

Страница 24: ...ve of an internal circuit Contact the nearest customer service for technical assistance The RF card works normally but the key input for the card number using the keypad does not work properly Use the...

Страница 25: ...able of the converter RX Port TX RX TX GND GND TX RX TX RX Rs 422 Multi Unit Communication SSA P400 SSA P400 RS 232 RS 422 PC RX RX TX Connected to the RS 232 cable of the converter RX RX TX TX TX RX...

Страница 26: ...t Burst for PIN Door Open Time 00 99 Sec Default 3Sec Communication RS232 RS422 RS485 RS232 RS422 RS485 TCP IP RS232 RS422 RS485 RS232 RS422 RS485 TCP IP Baud Rate bps 9 600bps Input Port 15ea Output...

Страница 27: ...aste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that...

Отзывы: