E
&
ALARM FUNCTION
●
The monitor can be connected to various alarms. It has an output port that sends the
alarm signal to another device on+5V TTL level for alarm setting time.
●
When the alarm goes off in QUAD or AUTO mode, the monitor automatically switches
to the screen of the camera where the alarm is generated and displays a blinking “A”.
●
If the alarm breaks out at two or more places, the monitor switches to the QUAD
screen mode and displays a blinking A on the relevant screens.
●
Once the alarm is released, the monitor goes back to the previous mode automatically.
●
While the alarm continues, it cannot be reset. Remove the alarm factors.
In VCR or SETUP mode, the monitor switches to the alarm channel automatically.
●
A.RESET only resets the alarm time after the alarm factor is removed.
●
To disable the alarm completely (the alarm is not detected), set the alarm time to “OFF”
in the Setup Menu.
●
If you make the alarm off in the mode of VCR and SETUP mode, the system doesn’t
go back to VCR or SETUP mode.
●
Alarm in the case of sub power off, the display is on.
*
AUDIO SYSTEM
●
This has One-way audio system. It is possible in quad mode or C1~C4 full screen
mode.
●
You can hear the sound from the selected camera without pressing any button.
(
OTHER FUNCTION
●
Volume doesn’t work in setup mode, and OSD is displayed 1.5 second while volume is
controlled.
●
Please watch out at sub power mode, this is only for display off but electric power on
for system. No buttons or keys are not in active when sub power off.
●
If a camera is disconnected, the channel display is in freeze, and if it is connected
again, freeze will be off.
●
Power on set QUAD mode
31
MODE
C1~C4
C5~C8
PAGE A
one or more
none
PAGE B
none
one or more
PAGE A
none
none
PAGE A,B SWITCHING
one or more
one or more