Содержание SMH9207ST/XAA

Страница 1: ...14 for 30 seconds while a weight sensor in operation E 34 The initial value of K calculated by a weight sensor is above and under 28 as value of HEX E 35 The value of A is as a weight sensor calculates E 36 In case the door opens during sensor cooking Error Code Gas Sensor Error Case E 1X E 41 Open E 42 Short E 43 T1 Max Time Error E 44 Dry Up E 45 Cooling Error 3minutes E 46 Primary Open Error 3m...

Страница 2: ......

Страница 3: ...ower and remove grille and Assembly Control Box 2 Replace the fuse 3 When 20A fuse blows out by the operation of interlock monitor switch failure replace the primary interlock switch secondary interlock switch door sensing switch interlock monitor switch and power relay 4 When the above four switches operate properly check if any other part such as the control circuit board blower motor or high vo...

Страница 4: ...nately both of the new boards are described a ASSY PCB MAIN For the purposes of troubleshooting we will refer to the 2 boards as follows Relay Circuit Board Assy ASSY PCB MAIN Large board located in ASSY Control BOX Control Circuit Board Assy ASSY PCB MAIN Located in in the ASSY DOOR Check if AC voltage is present at the Relay Circuit Board assy MAIN Measure for 120VAC between CN01 Pin 1 B6 and th...

Страница 5: ...is present during any cook cycle Before touching any components or wiring always unplug the oven and discharge the high voltage capacitor Some semiconductor solid state devices are easily damaged by static electricity Such components are called Electrostatically Sensitive Devices ESDs Examples include integrated circuits and field effect transistors Immediately before handling any semiconductor co...