![Samsung SMG-3200 Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/samsung/smg-3200/smg-3200_user-manual_346102099.webp)
5-23
[4] SLC Signal
Function
You can set the signal type of the SLC interface.
Procedure
1. In the <PSTN Configuration Menu> screen, type ‘4’, and press [Enter].
<<<<< SLI Signal >>>>>
+---+-------------------+------+---------+-------+
| No | SLI Signal Timer
| Value
| Unit
| Default
|
+---+-------------------+------+---------+-------+
| 0
| Hook Off Time
| 1
| 100 msec
| 1
|
| 1
| Hook On Time
| 50
| 10 msec
| 50
|
| 2
| Hook Flash MIN. Time
| 10
| 10 msec
| 10
|
| 3
| Hook Flash MAX. Time
| 30
| 10 msec
| 30
|
+---+-------------------+------+---------+-------+
[ . :Exit ]
2. Input the number of the SLC signal to be changed, and press [Enter].
Configuration Item Number:
3. Specify a value referring to the following table, and press [Enter].
No
No
No
No
Item
Item
Item
Item
Description
Description
Description
Description
0
Hook Off Time
The minimum time elapsed to recognize hook off of
an analog telephone. Typed number x 100msec is
the actual hook off time.
1
Hook On Time
The minimum time elapsed to recognize hook on of
an analog telephone. Typed number x 10msec is the
actual hook on time.
2
Hook Flash MIN.
Time
The minimum time elapsed to recognize hook flash
of an analog telephone. Typed number x 10msec is
the actual hook flash time.
3
Hook Flash MAX.
Time
The maximum time elapsed to recognize hook flash
of an analog telephone. Typed number x 10msec is
the actual hook flash time.